1 / 8

Portable Data and Modeling for Electromagnetic Transient Analysis programs

Portable Data and Modeling for Electromagnetic Transient Analysis programs. Jean Mahseredjian jeanm@polymtl.ca Ecole Polytechnique de Montreal. New IEEE Task Force. Co-chairmen: Jean Mahseredjian and Taku Noda Portable Data and Modeling for Electromagnetic Transient Analysis programs

dwillard
Download Presentation

Portable Data and Modeling for Electromagnetic Transient Analysis programs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Portable Data and Modeling for Electromagnetic Transient Analysis programs Jean Mahseredjian jeanm@polymtl.ca Ecole Polytechnique de Montreal

  2. New IEEE Task Force • Co-chairmen: Jean Mahseredjian and Taku Noda • Portable Data and Modeling for Electromagnetic Transient Analysis programs • Objectives • Explore the possibility to define a portable (common) input format (PIF) for all electromagnetic transient programs (EMTP-type programs) • Ultimately the format may be extended to modeling methods/definition in addition to modeling data • Ultimate goal: Establishment of a standard • Participants: • Off-line and real-time EMTP-type software vendors • Universities • Utilities (important support due to predicted impact)

  3. Subject • Simulation and analysis of power system transients • EMTP-type applications: • Capability to simulate electromagnetic transients • Capability to simulate electromechanical transients (detailed) • Time-domain simulations, circuit based • Wideband models: from steady-state to switching transients and to lightning • Time-steps: microseconds, rarely exceeds 0.5 ms • Duration of simulation: 50 – 400 seconds • For very large networks, a simulation for 59 secs can take a day

  4. Current Situation • Modern EMTP-type packages include multiphase load-flow solvers • By comparison, PSS/E does electromechanical transients and steady-state • EMTP can do the same, but with much higher precision. It simulates and finds the waveforms (exact) and includes harmonics • PSS/E will  find phasors but does not include harmonics • Current Situation • There are no portability standards between applications in the same field • CIM: needs to be augmented to include EMTP attributes

  5. Importance of Portability • Model reusability • Increased productivity: industry and research • Benefiting from the advantages of various applications • Example: same design for offline and real-time simulations • Example: controller design, controller simulation • Single model design: plug-and-play models • Same model for several frequency ranges • From load-flow to transients (electromechanical, electromagnetic, mean-value models, manufacturer codes) • Codes for control systems • Codes for power devices or complete systems with controls • Futuristic: plug-and-play and drag-and-drop

  6. UML, XML, DTD, RDF, CIM/CPSM • Unified Modeling Language • Defines notation and semantics for object-oriented models • Graphical representation • XML: eXtensible Markup Language • DTD: Document Type Definition • Resource Description Framework • IEC 61970-501: XML format for network model exchanges using RDF • CIM/XML: Translated into XML using the relational RDF syntax to describe instances of CIM objects and their relationships • CPSM: Common Power System Model (IEC 61970-452) • XML data file transfer requirements, subset of classes • Adopted by NERC: standard for TSO data exchange 6

  7. CIM/EMTP-RV • Translation to a proprietary format • Topological data • Unique identifiers for devices • Device data • Specific model issues • Validation • Elimination of useless data for simulation • Example: Extra breakers • Usage of CIM/CPSM for filtering data • Object mapping • ACLineSegment: PI-section • ShuntCompensator: RLC • EnergyConsumer: PQ load • GeneratingUnits and SynchronousMachines: PV, PQ or slack • Graphical presentation • Automatic drawing, positioning, positional data • Various presentation aspects • New requirements for existing applications 7

  8. Challenges • EMTP-type models are complex • There are more differences between solution and modeling methods from various software vendors • There is a strong requirement from vendors and users to maintain Graphical User Interface visualization of networks • The new standard must develop GUI portability • The GUIs are complex • CIM-XML or just XML? • Establishing a new XML standard from scratch will simplify the standardization path. • Compatibility with CIM has many advantages: established standard, exchanging with traditional power system software packages, visibility