1 / 22

Understanding Contact Lens Interactions with the Tear Film

Explore the impacts of contact lenses on the tear film's dynamics, quality, and stability for improved ocular comfort. Discover the biophysical and biochemical changes induced by contact lens wear.

earlholcomb
Download Presentation

Understanding Contact Lens Interactions with the Tear Film

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Contact Lens Interactions with the Tear Film Subcommittee Report Members: Jennifer Craig (Chair & SC Liason) Mark Willcox (Workshop Vice-Chair) Pablo Argueso Cecile Maissa Ulrike Stahl Alan Tomlinson Jianhua Wang Norihiko Yokoi Fiona Stapleton (Harmonization Subcommittee Member)

  2. Interactions with the Tear Film Subcommittee The tear film is crucial to ocular surface health, and a contact lens, by its very presence, affects the tear film, and therefore has the potential to affect comfort

  3. Interactions with the Tear Film Subcommittee Effects on the tear film Biophysical - changes to dynamics and quality Biochemical - compositional changes

  4. Interactions with the Tear Film Subcommittee Biophysical & biochemical tear film aspects • Comprehensive review of the literature on each topic with respect to: • the pre-corneal (non-CL) tear film • the tear film in the presence of a CL • the impact of that aspect on discomfort in CL wear • Evaluation of deficiencies in the current literature, together with suggestions for future research

  5. Interactions with the Tear Film Subcommittee • Tear film dynamics • Blink impact on tear film • Lipid layer quantity and quality • Evaporation • Stability • Temperature • Thickness • Turn over • Volume / CL edge profile • Exchange (post-lens) • Tear film quality • Osmolality • Ferning • pH • Viscosity

  6. Interactions with the Tear Film Subcommittee • Biochemistry • Lipidome • Proteome • Mucins, glycocalyx and “mucin” balls • Other components • Cellular content (PMNs) • Contaminants

  7. Interactions with the Tear Film Subcommittee Blink impact • CL – blink frequency to compensate for  TBUT • Incomplete blinks in hydrogel CL wear linked to: • increased fluorescein staining • discomfort and increased lens deposition1 Lipid layer (LL) • Lipid layer   surface tension and  evaporation • In CL wear, LL thickness and uniformity are  due to  aqueous layer thickness2 • No clear relationship with comfort

  8. Interactions with the Tear Film Subcommittee Evaporation • Non-CL: Evaporation  with incomplete lipid layer • CL   evaporation (x 1.2 – x 2.6) associated with  stability, independent of lens material • Under adverse conditions, evaporation related to discomfort in hydrogel, but not SiHy, CL wearers3 Temperature • Surrogate measure for tear film evaporation and/or stability • No clear relation with comfort

  9. Interactions with the Tear Film Subcommittee Tear film stability • Evaluated with TBUT / NIBUT tests or dynamic tests • Lipid thickness closely associated with TBUT,thus, in CL: Aqueous   lipid layer spread TBUT 4 • *non-material specific • Pre-corneal TBUT  initially but longer term changes in post-removal TBUT* not observed5

  10. Interactions with the Tear Film Subcommittee Relation of stability to comfort • With soft CL, discomfort is observed with TBUT6,7 • Pre-lens TBUT < 3 s predicts symptomatic CL wear8 • With CL, under adverse environmental conditions:  relative humidity   stability  symptoms9 • Wearers unable to tolerate 6 hrs CL wear have lower NIBUT than tolerant wearers (13s vs 20s)10

  11. Interactions with the Tear Film Subcommittee Tear film thickness • Normal thickness around 3µm • In CL, PLTF around 2µm on stabilisation11 • PoLTF approximately 1 – 3µm11 • No established association with discomfort Tear turnover rate • No consistent change in TTR with CL wear • However, immediately post lens removal, TTR in symptomatic individuals is less than that in asymptomatic individuals12

  12. Interactions with the Tear Film Subcommittee Tear volume • Total volume in non-CL eye around 2 to 4µl11 • In CL, meniscus volume from around 1.5 to 1.0µl11 • Limited but significant effect of tear volume on comfort10, 13 Meniscus profile • Altered in soft CL wear13 • No association with CL discomfort established

  13. Interactions with the Tear Film Subcommittee Tear Exchange •  with  lens size,14 but not linked with discomfort Osmolarity • No consistent effect of adapted CL wear on osmolarity15 • Relation to discomfort equivocal15, 16 Ferning • Ferning grade increases with CL wear17 • Can differentiate CL and non-CL wearers, but ability to predict intolerance not currently confirmed17, 18

  14. Interactions with the Tear Film Subcommittee pH • by 0.27 – 0.53 units in CL wear19but is not clearly related to comfort20 Viscosity • effects of CL unknown Surface tension • no studies specific to CL wear • some biochemistry changes (lipids, sPLA2, lipocalin) may relate to changes to surface tension21

  15. Interactions with the Tear Film Subcommittee Changes in tear biochemistry Lipidome: phospholipid levels (due to  sPLA2)21 is conceivably a contributing factor in CL discomfort Proteome: Most major proteins unaffected by CL wear Possible increases in cytokines  lipocalin-1 in CL intolerance21 Mucins: Relation to tolerance inconclusive22, 23 Possible relation between pattern of mucin degradation and CL discomfort24

  16. Interactions with the Tear Film Subcommittee Summary • CLs induce: stability, lipid layer and volume  evaporation rate • To date, the effect on comfort of many of these biophysical properties is unknown or inconclusive

  17. Interactions with the Tear Film Subcommittee Conclusions • absence of a consistent definition has hindered the correlation of biophysical and biochemical tear film parameters with discomfort • the close relationship that exists between tear film stability, ocular surface temperature, and tear evaporation suggests that interventions that modify one aspect will influence all • consideration of tear type important in relating tear film biochemistry to discomfort

  18. Interactions with the Tear Film Subcommittee Future directions • to define the biophysical and biochemical properties inherent to the structural integrity of the normal non-CL tear film • to develop lens materials, designs and surfaces that promote biocompatibility … • and refine the wetting agents within CL care solutions for long-term wettability of the CL surface … … to a level that allows the tear film to remain stable over the CL surface and support an adequate lipid layer

  19. Interactions with the Tear Film Subcommittee Thank you • TFOS • Contact Lens Interactions with the Tear Film Subcommittee • Sponsors

  20. Interactions with the Tear Film Subcommittee References • Collins M, J , Stahmer D, Pearson G. Clinical findings associated with incomplete blinking in soft lens wearers. ClinExpOptom 1989;72:55-56. • Yokoi N, Yamada H, Mizukusa Y, et al. Rheology of tear film lipid layer spread in normal and aqueous tear-deficient dry eyes. Invest Ophthalmol Vis Sci 2008;49:5319-5324. • Kojima T, Matsumoto Y, Ibrahim OM, et al. Effect of controlled adverse chamber environment exposure on tear functions in silicon hydrogel and hydrogel soft contact lens wearers. Invest OphthalmolVis Sci 2011;52: 8811-8817. • Guillon JP, Guillon M. Tear film examination of the contact lens patient. Contax 1988;14-20. • Chui WS, Cho P, Brown B. Soft contact lens wear in Hong Kong-Chinese: predicting success. Ophthalmic Physiol Opt 2000;20:480-486. • Fonn D, Dumbleton K. Dryness and discomfort with silicone hydrogel contact lenses. Eye Contact Lens 2003;29:S101-104 • Glasson MJ, Hseuh S, Willcox MD. Preliminary tear film measurements of tolerant and non-tolerant contact lens wearers. ClinExpOptom 1999;82:177-181. • Hom MM, Bruce AS. Prelens tear stability: relationship to symptoms of dryness. Optometry 2009;80:181-184.

  21. Interactions with the Tear Film Subcommittee References • Maruyama K, Yokoi N, Takamata A, Kinoshita S. Effect of environmental conditions on tear dynamics in soft contact lens wearers. Invest Ophthalmol Vis Sci 2004;45:2563-2568. • Glasson MJ, Stapleton F, Keay L, Sweeney D, Willcox MD. Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers. Invest Ophthalmol Vis Sci 2003;44:5116-5124. • Chen Q, Wang J, Tao A, Shen M, Jiao S, Lu F. Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses. Invest Ophthalmol Vis Sci 2010;51:1988-1993. • Tomlinson A, Fagehi R, Manahilov V. Why do some contact lens wearers avoid contact lens dry eye symptoms? , 90th Annual Meeting of the American Academy of Optometry. Phoenix, AZ, USA; 2012:E-abstract 120286 • Chen Q, Wang J, Shen M, et al. Tear menisci and ocular discomfort during daily contact lens wear in symptomatic wearers. Invest Ophthalmol Vis Sci 2011;52:2175-2180. • McNamara NA, Polse KA, Brand RJ, Graham AD, Chan JS, McKenney CD. Tear mixing under a soft contact lens: effects of lens diameter. Am J Ophthalmol 1999;127:659-665. • Stahl U, Willcox M, Naduvilath T, Stapleton F. Influence of tearfilm and contact lens osmolality on comfort in CL wear. Optom Vis Sci 2009;86:857-867.

  22. Interactions with the Tear Film Subcommittee References • Stahl U, Willcox M, Naduvilath T, Stapleton F. Influence of tearfilm and contact lens osmolality on comfort in CL wear. Optom Vis Sci 2009;86:857-867. • Evans KS, North RV, Purslow C. Tear ferning in contact lens wearers. Ophthalmic Physiol Opt 2009;29:199-204. • RavazzoniL, Ghini C, Macri A, Rolando M. Forecasting of hydrophilic contact lens tolerance by means of tear ferning test. Graefes Arch ClinExpOphthalmol 1998;236:354-358. • Chen FS, Maurice DM. The pH in the precorneal tear film and under a contact lens measured with a fluorescent probe. Exp Eye Res 1990;50:251-259. • McCarey BE, Wilson LA. pH, osmolarity and temperature effects on the water content of hydrogel contact lenses. Contact Intraocul Lens Med J 1982;8:158-167. • Glasson MJ, Stapleton F, Willcox MD. Lipid, lipase and lipocalin differences between tolerant and intolerant contact lens wearers. Curr Eye Res 2002;25:227-235. • Berry M, Pult H, Purslow C, Murphy PJ. Mucins and ocular signs in symptomatic and asymptomatic contact lens wear. Optom Vis Sci 2008;85:E930-938. • PisellaPJ, Malet F, Lejeune S, et al. Ocular surface changes induced by contact lens wear. Cornea 2001;20:820-825. • Berry M, Purslow C, Murphy PJ, Pult H. Contact lens materials, mucin fragmentation and relation to symptoms. Cornea 2012;31:770-776.

More Related