210 likes | 385 Views
Analysis of Heterojunction Bipolar Transistors. Outline. 3-D Structure of Single Finger and Three Fingers C-up HBT A 3-D modal of single finger and three fingers C-up HBT Adjust the Thickness of PHS Layer and GaAs Substrate Compare with the results of 2- D modal
E N D
Outline • 3-D Structure of Single Finger and Three FingersC-up HBT • A 3-D modal of single finger and three fingers C-up HBT • Adjust the Thickness of PHS Layer and GaAs Substrate • Compare with the results of 2- D modal • The results under the different boundary condition • Conclusion
Temperature distributions in C-up HBT of 3-D Modal (1/4 Symmetry)
Temperature distributions in C-up HBT of 3-D Modal Shows by Isosurface (1/2 Symmetry)
3- D Modal Temperature distributions Compare with the Results of 2- D Modal The Temperature distributions of 3- D Modal The Temperature distributions of 2- D Modal
3- D Modal Temperature distributions Compare with the Results of 2- D Modal (con.) The Temperature distributions of 3- D Modal The Temperature distributions of 2- D Modal
398 298.5 Comparison of temperature distribution in C-up HBT with a thicker and a thinner thermal via Original thicker thermal via: Substrate=19.5um; PHS=8um A thinner thermal via: Substrate=13.5um; PHS=6um
Temperature distributions in C-up HBT of 3-D Modal by Finger Pitch = 18 um (1/4 Symmetry)
Temperature distributions in C-up HBT of 3-D Modal by Finger Pitch = 10 um (1/4 Symmetry)
Temperature distributions in C-up HBT of 3-D Modal Shows by Isosurface (1/2 Symmetry) Finger Pitch = 18 um
Temperature distributions in C-up HBT of 3-D Modal Shows by Isosurface (1/2 Symmetry) Finger Pitch = 10 um
3- D Modal Temperature distributions Compare with the Results of 2- D Modal (Finger Pitch = 18 um ) The Temperature distributions of 3- D Modal The Temperature distributions of 2- D Modal
3- D Modal Temperature distributions Compare with the Results of 2- D Modal (con.) The Temperature distributions of 3- D Modal The Temperature distributions of 2- D Modal
Conclusion • The relation of maximum temperature to substrate thickness is linear, and the relation of maximum temperature to PHS thickness is a cubic equation in 2D and 3D analysis. • The temperature distribution of 3D modal is similar to 2D modal, but the result of 2D modal is higher than that of 3D modal. • The 3D analysis of 1-finger C-up HBT shows that the thickness of thermal via can be reduced 32% to provide the same thermal performance.