Air-cooled Inverter Product Range

Air-cooled Inverter Product Range. Updated by: Yap Boon Thiam Technical Engineer Email: yapbt@oyl.com.my Date: 14/5/2012. Inverter Product Range. Contents: Product Range: Single Split Inverter (Series I) Single Split Inverter (Series II) Multi Split Inverter Inverter Control

edan-pitts
Download Presentation

Air-cooled Inverter Product Range

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Air-cooled Inverter Product Range Updated by: Yap Boon Thiam Technical Engineer Email: yapbt@oyl.com.my Date: 14/5/2012

  2. Inverter Product Range • Contents: • Product Range: • Single Split Inverter (Series I) • Single Split Inverter (Series II) • Multi Split Inverter • Inverter Control • Troubleshooting Guidelines

  3. Inverter Product Range Single Split Inverter Series I

  4. Inverter Product Range Single split Inverter Series I – A5LCY 5WMY-JR 5WMY-LR 5CKY-ER 5CMY-ER 5CCY-CR

  5. Inverter Product Range Wall Mounted – A5WMY New Vs A5WMY10/15LR A5WMY10/15JR

  6. Inverter Product Range A5WMY-Features • High EER/COP performance. • ALL Models rank A/A or Exceeds! • High Quality & Efficiency DC Inverter compressor

  7. Inverter Product Range A5WMY-Features • BioPro IAQ. • Protection 1 • Bio Antibody Filter • Able to eliminate up to 99.99% of various airborne infectious viruses • Deactivates influenza virus • Protection 2 • Titanium Apatite Filter • Dissolves odors and harmful airborne particles like dust, bacteria • -Enhance photo catalytic capability • Note: Standard for LR series and Optional for JR series

  8. Inverter Product Range A5WMY-Features • New Remote Control • Turbo Mode- Fast cooling • Quiet Mode • Error code diagnosis GS02

  9. Inverter Product Range A5LCY Series 1- Specification • Maximum piping length and elevation

  10. Inverter Product Range A5LCY Series I- Features • Outdoor Control Box • Made of plastic material • More compact and lighter A5LCY-DR A5LCX-CR New

  11. Inverter Product Range A5LCY Series I- Features • Ease for Servicing • Equipped with 7 segment display • Able to retrieve error code and running parameter

  12. Inverter Product Range A5LCY Series I- Features • Thermistor New Heat sink thermistor to detect heat sink temperature

  13. Inverter Product Range Single Split Inverter Series II

  14. Inverter Product Range Single split Inverter Series II – A5LCY 5CKY-ER 5CMY-ER 5CCY-CR

  15. Inverter Product Range Ceiling Cassette – A5CKY-ER Features • Improve sound level • Equipped with a newly-developed turbo fan • 4 selected fan speeds inclusive of Quiet mode Improved!

  16. Inverter Product Range Ceiling Cassette – A5CKY-ER Features • Optimum air discharge • Multi comfort 3 air swing pattern CK-A CK-E

  17. Allow 90°Rotation Inverter Product Range Ceiling Cassette – A5CKY-ER Features • Modern and Elegant design • Unique “Round” side contour • Side LED light location • Even air distribution • Rotatable intake grill A5CKY-ER A5CKY-AR

  18. A B C Inverter Product Range Ceiling Cassette – A5CKY-ER Features • Compact Body Design A5CKY20-28ER 290mm A5CKY40-50ER 325mm A5CKY20-50AR 350mm Lower Height!

  19. Inverter Product Range Ceiling Cassette – A5CKY-ER Features • Built in high head drain pump • 700mm drain head • Water level switch is incorporated with drain pump to monitor its water level

  20. Inverter Product Range Ceiling Convertible– A5CMY Features • Automatic air swing • The motorized louver enables the air flow to be evenly distributed • Maximum piping length and elevation

  21. Inverter Product Range Ceiling Convertible– A5CMY Features • Optional drain pump • Flexible installation at side • 700mm drain head

  22. Inverter Product Range LED Indicator- A5LCY28CR

  23. Inverter Product Range LED Indicator- A5LCY40/50/60FR

  24. Inverter Product Range Multi Split Inverter

  25. Inverter Product Range Multi-split Inverter – A5MSY 5WMY10/15LR 5WMY10/15/20JR 5CMY15/20ER 5CCY10/15/20CR 5CKY10/15/20CR 5CKY20ER

  26. Inverter Product Range A5MSY18BR • Focus on residential market with 1 Bedroom + 1 Living Room • More compact design and cost effective

  27. Inverter Product Range A5MSY- Specification • Maximum piping length and elevation

  28. Inverter Product Range A5MSY- Features • Better Energy Saving • Achieve class A/A based on European Energy Efficiency Class ratings

  29. Inverter Product Range A5MSY- Features • Outdoor Control Box • Made of plastic material • More compact and lighter A5MSY-BR A5MSX-AR

  30. Inverter Product Range A5MSY- Features • LED light error indicator (self error diagnosis)

  31. Inverter Product Range A5MSY - Features • More feedback (Thermistors) • Outdoor unit has more feedbacks New New New

  32. Inverter Product Range A5MSY- Features • Outdoor Fan Motor • Compressor and Expansion Device • Has a higher EER, lower vibration & noise and higher durability

  33. Inverter Product Range A5MSY - Features • Wiring Error Check • Self corrected wiring connection just pressing a button (SW3) • After self-correction, OD will change the address in memory so that EXV A is link to Port B. • Note: Wire check correction need to be carried out again if wiring is changed or corrected

  34. Inverter Product Range A5MSY - Features • Priority Room Setting • Allow user to set a particular room which takes precedence over the operation mode of other rooms • For example, if Room A is the priority room, when COOL mode is selected in Room A while Room B, C & D are operating in the following mode:

  35. Inverter Product Range A5MSY – Literatures Brochure Manuals Installation Manual GS02 Handset Operating Manual

  36. Inverter Products Control

  37. Inverter Product Range Operating Mode • There are 5 operating modes: • Cool mode • When Tr ≥ Ts - 1.5°C -Comp, ID Fan and OD Fan ON • When Tr ≤ Ts - 2°C ** -Comp and OD Fan OFF, ID Fan remain ON • **When room temperature falling below compressor cut off • point even on the lowest operation frequency, compressor will • stop operates. Tr = Room Temperature Ts = Set Temperature Tr <= Ts - 2°C Comp will stop Lowest Freq Time

  38. Inverter Product Range Operating Mode • There are 5 operating modes: • Heat mode • When Ts > Tr - 1.0°C -Comp, ID Fan and OD Fan ON • When Tr ≥ Ts + 1.5°C ** -Comp and OD Fan OFF, ID Fan remain at lowest speed if ID coil ≥ 27°C • **When room temperature rising above compressor cut off • point even on the lowest operation frequency, compressor will • stop operates. Tr = Room Temperature Ts = Set Temperature Tr - Ts ≥ 1.5°C Comp will stop Lowest Freq Time

  39. Inverter Product Range Operating Mode • There are 5 operating modes: • Fan mode • Only High, Medium and Low fan speeds are allowed • Changing cool mode to fan mode; the compressor and outdoor fan will stop • Compressor will only ON if the minimum stop time is > 3 minutes if the user change back to cool mode

  40. Inverter Product Range Operating Mode • There are 5 operating modes: • Auto mode (for single split) • Mode switching point: • Heating  Cooling • Tr ≥ Ts + 2.5 • Cooling  Heating • Tr ≤ Ts – 2.5 • During initial operation • Cooling operation: Tr > Ts • Heating operation: Tr < Ts Tr = Room Temperature Ts = Set Temperature

  41. Inverter Product Range Operating Mode • There are 5 operating modes: • Auto mode (for multi split) • Without Priority Room Setting • If more than 1 indoor is operating, priority is given to the first unit that was turned on • If a unit is turned on later to the same operating mode as the first unit, the unit will operate as normal • If a unit that are turned on later to the different operating mode as the first unit, the units will enter Standby mode • With Priority Room Setting • Unit operation subjected to Priority Room operating mode

  42. Inverter Product Range Communication • Communication between ID and OD • Master by outdoor unit • Indoor PCB transmits signal to outdoor PCB every 0.5s. Outdoor unit will response to indoor once the valid data is received • If the data communication line between indoor and outdoor disrupted for 15s continuously; Compressor will stop, OD fan will stop with fan delay timer. ID LED starts blinking error • If the communication resumes within 15s; error code will be cleared and compressor restarts after 3 minutes • If the communication does not resume after 15s; unit unable to restart and ID LED continues to blink

  43. Inverter Product Range Minimum Run Control • To prevent frequent compressor ON/OFF and to allow pressure equalization • The compressor will be on 3 minutes stand-by after turning OFF before it is allowed to turn ON • OD fan delay by Off timer to improve pressure equalization and to prevent refrigerant from entering into evaporator

  44. Inverter Product Range Auto Restart • Allow unit to automatically resume the same operating mode it was in before a power failure • Factory pre-set • Change over switching is only carried out during operation 4 Way Valve Control

  45. Inverter Product Range Defrost Cycle

  46. Inverter Product Range Defrost Cycle- A5LCY Series I • Condition for entering defrost • Compressor minimum run time of 6 minutes; OR • Compressor accumulated run time of 45 minutes if OD coil < 3C • When OD coil < 0C AND OD coil < OD air - 10C • Condition for terminating defrost • OD coil > 12C; OR • Total defrost timer of 650 seconds

  47. Inverter Product Range Defrost Cycle- A5MSY • Condition for entering defrost • Compressor minimum run time of 6 minutes; OR • Compressor accumulated run time > 38 minutes • Based on OD coil temperature, output frequency & OD air temperature • Condition for terminating defrost • Minimum run time of 120 seconds; AND • Determine based on OD ambient, in the range of 4C ≤ OD coil ≤ 12C; OR • Totaldefrost timer of 650 seconds

  48. Inverter Product Range Indoor coil freeze prevention • Outdoor fan control is carried out: • Only available in cooling mode • When the indoor coil temperature < 2°C, the compressor starts to drop the frequency • This protection will cut in when: • Indoor coil temperature < 0°C for more than 180s. • Compressor will stop, OD fan stop after 30s and indoor fan can only run at lowest fan speed • The unit can only be restarted after 3 minutes • When the indoor coil temperature > 13°C, the compressor frequency will be reset based on the OD ambient, room and set temperature

  49. Inverter Products Troubleshooting Guidelines

  50. Inverter Product Range Error Indication • From Indoor panel • When error occurs, indoor LED display will start • blinking continuously: Green light • The blinking pattern does not indicate of error details • The error details could be retrieved from handset