570 likes | 782 Views
Vortex Training. Market Analysis, Background Information, New Electronics - Features, Options, Diagnostics. Vortex Training. Vortex Meter Market Size and growth projections Major Markets Background Information Theory and operation Product information New Features Electronics
E N D
Vortex Training Market Analysis, Background Information, New Electronics - Features, Options, Diagnostics
Vortex Training • Vortex Meter Market • Size and growth projections • Major Markets • Background Information • Theory and operation • Product information • New Features • Electronics • Velocity pickup • Wiring • Software • Communications • HART • MODBUS • Fieldbus • FF • PROFIBUS PA • Diagnostics • Simulation Program
Vortex Meters - Marketplace • Projected Size and Growth
Vortex Meters - Marketplace • Major Markets by Region
Vortex Meters - Marketplace • Projected Sales by Type
Vortex Meters - Marketplace • 2005 Market Share Estimates
Major Markets • District Heating • Steam Flow • Chilled Water • Hot Water • Industrial Markets • Steam Flow • Industrial bulk gas • Compressed Air • Natural Gas • Gas Vapors • Petroleum derivatives
Vortex Meter Background • In 1911 he made an analysis of the alternating double row of vortices behind a stone, bluff body, in a fluid stream, now famous as Kármán's Vortex Street. This happens when the fluid that flows around a body fails to stick to the shape, but instead breaks off behind it into a wave. He also noted that the distance between the vortices was constant and depended solely on the size of the rock that formed it. • Theodore von Karman
Examples of Karman’s Vortex Street We’ll use a heated plate as the Bluff Body. The heat will provide the images using a thermal camera to view the generation of the vortices. In the first example of Von Karman Vortices, a heated plate with a thick initial thermal boundary layer is accelerated to 5 m/s in air. The boundary layer is swept downstream and rolls up into a pair of shed vortices. Temperature contours are shown in the movie making the flow visible
Example of Karman’s Vortex Street • Continuation from previous slide
Examples of Karman’s Vortex Street • Vortex formation in Nature • Vortices formed off of Gaudalupe Island
Examples of Karman’s Vortex Street • Vortex Formation in Nature • Flagpole acts as bluff body
Additional Findings • Von Karman also discovered the following Shedding frequency Fluid velocity!
From Nature to Meter – Velocity Calculation • Putting it all together • Vortices are alternately shed off a bluff body at a constant wavelength – the wavelength is determined by the bluff body width • Shedding frequency is proportional to velocity • Then: V = velocity f = frequency D = Bluff body width St = Strouhal number (dimensionless number used to characterize flow)
Strouhal Number • The Strouhal number is the ratio between the vortex wavelength and the shedder bar width. • It is a Reynolds number dependent variable but experiments have shown that at Re numbers above 10,000 it is essentially a constant
Simplifying the equations St = constant D = shedder body width = constant Rearranging the equation K = calibration factor (meter factor) Calculated during calibration
Physical Measurement • To become a meter we must measure the frequency • Two helpful facts • Vortices are alternately shed • A vortex is a low pressure zone
Physical Measurement • First vortex is generated: • Low pressure zone creates a DP across sensor • Sensor is “loaded” in the direction of the vortex • Next vortex passes on opposite side of sensor
Physical Measurement • Piezo-electric crystals • Generate a charge when loaded • Charge converted to a signal • Electronics measure frequency of signal • Electronic calculate velocity from frequency
What does all this mean? • Now that we have solved the velocity to frequency relationship we can arrive at • Q = volumetric flow rate • A = cross sectional area of pipe (meter body) • V = velocity
Temperature and Pressure • Temperature • 1000 ohm Platinum RTD • Pressure • Solid state Pressure Transducer • Located behind the velocity pickup • Proven using multi port sampling valve and numerous tests
Mass Flow Measurement • Compensated Volumetric Flowrate (SCFM) • “s” = Standard conditions (1 atm, 70° F) • “a” = Actual conditions
Pressure & Temperature Compensation • Tables pre-programmed for: • Water, Steam, Air, Ar, NH3 (Gas & Liquid), Cl2 (Gas & Liquid), CO, CO2, He, H2, CH4, N2, O2 • Other Gases & Liquids • Use Equations of State • Real Gas Law • API 2540 • Goyal Doraiswamy • AGA 8
Sizing Considerations – Liquid Low Flow • Low Flow – Major Consideration • Liquids • Reynolds Number limitation - typically liquid limiting factor • Minimum Measurable Velocity, Amplitude – typically associated with gas and steam
Sizing Considerations – Gas and Steam Low Flow • Low Flow – Major Consideration • Gases • Reynolds Number limitation - typically liquid limiting factor • Minimum Measurable Velocity, Amplitude – typically associated with gas and steam
Sizing Considerations – High Flow • Liquid High Flow Limitation • Gas and Steam High Flow Limitation • Resonance of the velocity tab is the limiting factor on the high flows – note that the ½” and ¾” meters have a limit of 180 fps and 230 fps
Insertion Reynolds Number Correction • Insertion Meters are designed to dynamically correct for pipe size and Re number • The larger the pipe the less total flow the insertion head sees • The higher the velocity the more constant the flow profile • The meters electronics takes into account the pipe size, the insertion depth and the predicted flow profile to compute the average flow reading throughout the meters range
Vortex Key Points • Vortex Meters are inherently linear – no square root extraction etc. • The shedding phenomena is independent of flowing media, i.e. gas, liquid, steam thus the meter can be calibrated on water and used on a gas by simply programming it for the fluid • No Moving Parts – No drift over time
Key Points • Temperature and Pressure Compensation • More than just a multi-variable • Ability to dynamically calculate density and to adjust for low Re numbers below 10,000 – remember the curve • Ability to measure mass flow with a single penetration • Multiple outputs from a single penetration
Product Portfolio • Volumetric Meter • Inexpensive option • Liquid applications • Sold on cost and relationship • Multiparameter Meter • Multiple outputs • 3 analog, 3 alarm, 1 pulse and HART • Options– Modbus, EMS ( Energy) • Sold on technological merit • Most commonly used on gas and steam • Energy option • Input options – temperature, pressure, alarm, etc.
Product Approvals • Sierra Innova vortex meter approvals • FM/FMC Class I Div 1, Groups B,C,D • FM/FMC Class II/III Div 1, Groups E,F,G • Canadian CRN • ATEX – submitted approval expected July or August 2007 • PED – work in progress expected July or August 2007
Product Portfolio • Inline • Flanged - ½” to 8” (DN15-DN200) – designs for 10” and 12” in near future • Wafer - ½” to 4” (DN15-DN100) • Materials of construction – Carbon Steel, Stainless Steel, Hastelloy • Insertion – 2” and up (DN50 and up) • NPT • Flanged • Packing Gland • Hot Tap with Retractor • Materials of construction – Carbon Steel, Stainless Steel, Hastelloy
Product Portfolio • Future Designs • Reducer for inline meters – already sold as a special – expected fourth quarter 2007 • Different materials of construction • Plastic inline • Plastic insertion • Specials Capability • High pressure flanged bodies • Special ANSI pipe schedules • Face to face dimensions
Competitive Comparison • Yokogawa • Product offering – Inline only • Flanged – ½”-12” • Wafer – ½”-4” • Multivariable with Temperature only • E&H • Product offering – Inline only • Flanged - ½”-12” • Wafer – ½”-6” • Multivariable with Temperature only
Competitive Comparison • Rosemount • Product offering – Inline only • Flanged - ½”-12” • Wafer – ½”-4” • Multivariable with Temperature only • ABB • Product offering – Inline only • Flanged - ½”-12” • Wafer - ½”-4” • Multivariable with Temperature only
Competitive Comparison • Pricing – N.A. list prices • Example: 2” 150LB Flange SS No Display Volumetric only • Yokogawa Price = $1850 • Rosemount Price = $2050 • E&H Price = $1750 • Sierra Price = $1840
Competitive Comparison • Pricing – N.A. list prices • Example: 2” 150LB Flange SS Local Display Volumetric only • Yokogawa Price = $2132 • Rosemount Price = $2300 • E&H Price = $2030 • Sierra Price = $2000
Competitive Advantage • Sierra Innova vortex product line • Widest range of meter configurations • Inline Meter • Insertion Meter • Low cost alternative to large inline meter • Little competition from major manufacturers • Multiparameter Technology • High Accuracy & Repeatability • Multiple Outputs • Wide fluid ranges, gas, liquids, steam • Little to no competition – sell on technological merit • Volumetric Technology • Ability to address low end commercial market • Competitive cost structure
Competitive Advantage • Sierra Innova vortex product line • Mechanical Features • Low Mass cantilevered velocity tab • Minimizes pipe stress effects • Low mass-small area design increase noise immunity • Design allows the sensor to be potted eliminating triboelectric affects • Signal Processing • New predictive filter techniques • Able to accurately predict amplitude and frequency from entered information to set filter • Better flow signal resolution • Driven cable allows for a greater signal ampitude and minimizes the triboelectric affect
New Product Features - Electronics • Velocity Pickup • 4 A/D converters with constant gain vs Variable Gain and 1 A/D converter • Reduces the possibility of amplifying noise • Better signal resolution • Loop Powered Mass • 24X Loop Power and HART • Same as 22X with the addition of T&P
New Product Features - Electronics • Wiring Layout • Backlight for 22X and 24X Loop Powered meters
New Product Features - Electronics • Wiring Layout • High Power DC • Option 1 and Option 2 – can be used for external inputs, i.e. pressure, temperature etc.
New Product Features - Electronics • Wiring Layout • 24X AC powered units now have a DC out terminal • Optional input terminals for external pressure, temperature or discrete alarm input • DC layout similar without the DC out option
New Product Features - Software • Communications • HART – Standard on volumetric, loop powered mass and mass meter • MODBUS – optional output – can be ordered on any configuration except that it makes the meter a high power unit – no longer loop powered • Fieldbus • Profibus PA – working with a consulting firm – expect it to be complete end of fourth quarter • Foundation Fieldbus – future after Profibus PA
New Product Features - Software • Units Menu • Added ability to display and output pressure units in Absolute or Gauge • Need to enter the atmospheric pressure at meter location – or default atmospheric, i.e. 14.7 psia at sea level