M2H Special Ratings- ELectroverge

This is a thin version of the 3 Amp model and control from 110u00b0-200u00b0C with 150mm leads. Tolerance : u00b17u00b0C(110 to 150u00b0C), u00b110u00b0(151 to 200u00b0C).

Download Presentation

M2H Special Ratings- ELectroverge

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. I TPS for mid temperature [110˚~200˚C] I M2H ( E rank only Features: 1.) Long life. 2.) Thin version with 150mm lead wire. 3.) Controls from 110 to 200˚C 4.) Dust proof : IP40 150 45.5 No mounting hole Two lead wires 8 MATSUO ELECT. M2H 16 7.5 Standard lead wire is AWM1726/AWG20 150mm length. Ratings and Characteristics: Table of contact capacity by voltage for M2H Operating voltage Temperature Setting Differential rank Contact capacity 110˚C ~ 200˚C E 0.5A ~ 2A AC250V DC24V AC125V DC12V 110˚C ~ 200˚C E 0.5A ~ 3A Table of contact capacity by voltage of M2HK Operating voltage Temperature Setting Differential rank Contact capacity 110˚C ~ 200˚C E 1mA ~ 50mA AC125V/AC250V DC12V/DC24V NOTE: The contact capacity of TPS for mid temperature will change depending on the voltage used/preset temperature/DIFF. ranking. : : : : : : : : : : : Maximum operating voltage Temperature setting range Temperature setting tolerance Differential Contact configuration Operating temperature range Protection rating Insulation resistance Contact resistance Withstanding voltage Vibration resistance Refer to the table above. 110˚C~200˚C ±7˚C(110˚C~150˚C), ±10˚C(151˚C~200˚C) rank E ······15±5 (10~20)˚C 1b(X) -30˚C ~ setting temperature +40˚C (no icing, no condensing) IP40 100MΩ or more 70mΩ or less (including lead wire resistance) AC2000V for 2 sec.(600V for 1 minute between contacts) Selected from JIS·C·0911-1984 Constant vibration; 50Hz fixed/0.2mm fixed (1G) Sweep vibration; 10~55Hz/0.35mm fixed (0.1~2.2G) Withstands 2 hour each in directions X, Y and Z. No damage when dropped three times from the height of 40cm onto a concrete floor (about 70G). No damage for double sealed model when dropped three times from the height of 1m onto a concrete floor. Withstands substantial impact after being put in a package or mounted in equipment. 10 million mechanical operations, 100,000 electrical operations at rated load. The thermostat withstands vibration and impact applied along Y and Z axis, but does not tolerate impact from X direction. (see the illustration below.) It is recommended that the thermostats be installed to minimize stresses applied along the X axis. TPS for mid temperature cannot have double sealing structure because of the heat resistivity issue of the material. : Impact resistance : : Life Handling precautions : Double sealed construction Strong Y X Weak Z Strong 11

More Related