1 / 1

Isolation Trip Timer

www.lingona.com.au. Isolation Trip Timer

elia
Download Presentation

Isolation Trip Timer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. www.lingona.com.au • Isolation Trip Timer • The LSLITT Isolation Trip Timing module from Lingona is 12/24VDC device that is designed to time delay shutdown of an electronic functional battery master isolation switch. When the key switch is turned to the OFF position ( loss of ignition supply ), the Isolation Trip module will begin time shutdown delay for a chosen time period before controlling the output isolation signal to disengage an electronic shut down functional battery master isolation switch. The LSLITT has an emergency stop activated shutdown application after a 30 sec delay shut down to ensure the engine is shut down before the isolation trip function is activated. • The Isolation Trip Timer kit includes- • LSLITT 12/24VDC operating control module (used for dual voltage 12 or 24 volt DC application ). • Note- the external relay required ( recommended HELLA 3062 for 24V application ) is not included. Isolation Trip Timing Module Installation Wiring Instructions Main Power Relay BATT IGN 12/24 V DC Key C/B Pos Power Supply Off Ignition Switch MACHINE SIDE OF Battery Isolator 12/24 V DC 3-WH 1-RD IGN Input BATT 10A Max C/B 5-BR 7-PU AUTO E-STOP S/DOWN n/a Optional Emergency Stop 8-OR Emergency Stop instant shutdown. Connect pins 5 & 6 through a normally closed contact for instant emergency stop shut down. N/C emergency stop contact system for instant isolation shutdown if emergency stops are applied. If not required connect these 2 x wires in pins 5 and 6 ( brown and green ) together. 6-GN n/a 2-BK AUX OUTPUT GND 4-YL Hella 3062 Relay 24v application Isolation Trip Timer Battery Isolator Lucas Shunt contacts Ground / Earth Connection Timing Selection DIP SW Settings S1- 1 min S2- 5 min S3- 10 min S4- 15 min C/Breaker, Ign Switch, emergency stop, Relay Not Inc 4 Distributed By Locksafe Industrial Safety Equipment

More Related