An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Evaluation of preprocessing methods in the development of near-infrared models for triticale protein and moisture Benoit Igne1, Lance R. Gibson2, Glen R. Rippke1, Charles R. Hurburgh, Jr1 1 Department of Agricultural and Biosystems Engineering, Iowa State University, Ames, Iowa. 2 Department of Agronomy, Iowa State University, Ames, Iowa.

  2. Background • Triticale: crossing between wheat and rye. • Greater vigor and yield than their parents. • Need efficient end-use properties measurements. • Evaluate the use of wheat calibration for triticale protein and moisture prediction. • Develop triticale specific calibrations. • Evaluate the use of preprocessing methods.

  3. Material and Methods • Triticale samples over 4-years trials. • 4 transmittance and 2 reflectance instruments. • Wheat calibrations from two instrument vendors. • PLS regression method. • Preprocessing methods: • Accepted by on-board instrument software: Autoscaling and Mean centering • Advanced methods 2nd derivative, SNV, and MSC

  4. Results – Use of wheat models Protein predictions Moisture predictions  Protein calibrations: Efficient the two first years.  Moisture calibrations: Usable for screening the first year, useless after.

  5. Results – Triticale specific models Protein predictions Moisture predictions  Protein calibrations: Advanced pretreatments gave better results (α = 0.05).  Moisture calibrations: No significant difference (α = 0.05).

  6. Conclusions • Use of wheat calibration is not recommended. • Advanced preprocessing methods gave better results with protein but not with moisture. • The effect of preprocessing methods is instrument and parameter dependent. • Additional samples from next years are needed.