Installation Questions abut the cooling water manifolds for the FD quads& sextupoles. Questions for Araki, Terenuma &/or Sugahara to answer before mid-January 2008. From Cherrill Spencer and John Amann ,SLAC ATF2 magnet group.
E N D
Installation Questionsabut the cooling water manifolds for the FD quads& sextupoles. Questions for Araki, Terenuma &/or Sugahara to answer before mid-January 2008 From Cherrill Spencer and John Amann ,SLAC ATF2 magnet group Water manifolds for FD magnets
How to deal with many cooling water hoses for the final doublet quadrupoles • Each FD quad has 8 cooling water inputs and 4 outputs which use US standard 37° flare water fittings- non-conducting hoses attach to them. • To simplify installation, SLAC proposes to use 2 manifolds for each quad. One 8-way for input and 4-way for output. • Will use JIS 30° flare ¾-14 water fitting to connect to KEK water system. This fitting will be tapped into manifold body with ¾-14 PT. It can be connected with hard pipe instead of JIS 30° flare if desired. • The 8-way manifold is 13”long x 3” diameter; the 4-way manifold is 7” long and 3 “ diameter– see drawings on next slide • Outstanding Questions for KEK people: • We do not want to mount these manifolds on the quad cores nor on the FD support table, in case they generate extra vibrations • Can the manifolds be mounted on the shielding wall to the side of the FD support table? • See next slide for more questions Water manifolds for FD magnets
Suggested designs for the 2 LCW manifolds for the ATF2 FD quadrupoles ( 2 of each type per quad) 4-way manifold:the Synflex hoses which go from manifold to quad will have US water-fittings on each end. The manifolds have a large BSPT thread at the end for connection to KEK water system (Japanese standard). 3” diameter & 7” long How long to make the hoses? Depends how far to wall. 8-way manifold. 3” diameter & 13” long We have drawn a generic “strap” with 2 bolt holes. Please let us know what kind of mounting you want Water manifolds for FD magnets
FD Sextupoles will have cooling hoses also – 2 hoses each • The FD sextupoles have one cooling water circuit each too. • Will need one input hose and one output hose each. • They could have two new manifolds with 2 fittings for each manifold. • They would also be mounted on the nearby wall. • Question for KEK people: do you want us to make some manifolds for the FD sextupoles’ cooling water? Water manifolds for FD magnets