Power consumption. Power consumption. Power consumption. The power consumption determined with the in orbit HK is consistent with The optical vacuum results (IA-AR-1000-9858-AER) The IASI /METOP ICD (MO-IC-MMT-IA-0001, Issue 7). Thermal lines activation.

ellery
Download Presentation

Power consumption

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Power consumption

  2. Power consumption

  3. Power consumption • The power consumption determined with the in orbit HK is consistent with • The optical vacuum results (IA-AR-1000-9858-AER) • The IASI /METOP ICD (MO-IC-MMT-IA-0001, Issue 7)

  4. Thermal lines activation • The heater lines of IASI are composed of : • 14 ATC lines for the thermal control of the instrument • 6 decontamination lines for the 300 and 200K decontamination of the radiator • 5 deployment lines for the CD, CCFD and LFDs deployment • Note : • The decontamination and deployments lines can not be switched on together • The decontamination lines are activated in the “Heater 1 Decontamination” mode in conjunction with the ATC (Warm-Up targets) • The deployment lines are activated individually (i.e. one by one) in the “Heater 1 deployment” mode in conjunction with the ATC (Warm-Up targets) • For all the higher modes, the ATC lines are activated in conjunction with the equipment switch on, at operational targets. • These lines are driven thanks to hardware automatons (one for the ATC, one for the Decontamination or Deployment activities)

  5. An HW automaton drives sequentially the heater lines @ 1 Hz

  6. An HW automaton drives sequentially the heater lines @ 1 Hz

  7. ATC Thermal lines Impedance Decontamination Thermal lines Impedance

  8. It is possible to establish the ripple on the EQPWR bus by injecting in the thermal simulation model the PWM and voltage acquired in the HK (4/11/06 09:37)

  9. EQPWR Ripples simulation data for the Heater 1Warm-Up & Heater 1 Decontamination are : • Heater 1 Warm-Up : 7.3 A • Heater 1 decontamination @300 K : 10.3 A • Heater 1 decontamination @200K : 7.6A • For the higher modes, combination of the simulated ripple of the heater lines and ripple measured during AIT activities allow to establish the following table (ripple at frequency 1, 4.8 and 1/8 Hz): IASI Deviation Request (IA-DR-1000-1115-AER) is updated • To integrate the ripple in decontamination mode (300K) • To update the ripple value for other modes