1 / 33

Respiratory Protection Air Sampling

Radiological Safety and Response RPT-243-PE-6. Respiratory Protection Air Sampling. Learning Outcomes Upon completion of this lesson, the student will be able to:. Inspect a full-face negative pressure respirator. Perform pre-use checks on a full-face negative pressure respirator.

elnorar
Download Presentation

Respiratory Protection Air Sampling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radiological Safety and Response RPT-243-PE-6 Respiratory ProtectionAir Sampling

  2. Learning OutcomesUpon completion of this lesson, the student will be able to: • Inspect a full-face negative pressure respirator. • Perform pre-use checks on a full-face negative pressure respirator. • Don a full-face negative pressure respirator. • Remove a full-face negative pressure respirator. • Obtain a air sample using available equipment • Perform required analysis and calculations to determine the airborne radioactivity concentration.

  3. Respiratory Protection

  4. Prior to Use in the Field • Medical Evaluation • Fit Tested • Field Tested (negative and positive pressure check)

  5. In the Mock-up Area • Since not all of the students have been screened medically – nor fit tested, you are not allowed to wear a respiratory protection device. • Therefore, you are not permitted to put the masks on your face with the filters installed. • Without the filters, it IS NOT a respiratory protection device.

  6. http://www.sharpesafety.com/catalog/images/7/1437.jpg Inspection • Lens • Face piece - sized based on fit test • Harness • Nose cup • Exhalation valve • Filters • Using a respirator wipe, clean the interior of the mask, sealing surface, and the exhalation valve thoroughly.

  7. Inspection Access the exhalation valve Squeeze the sides Remove the cover

  8. Inspection Check for foreign material under flapper valve and clean thoroughly then replace cover

  9. Inspection Inspect and thoroughly clean the sealing surface and interior

  10. Fitting • Loosen straps • Insert chin • Pull harness over head • Center harness on back of head • Tighten neck straps – one side at a time • Tighten top straps to adjust fit • Tighten temple straps (if present) – one at a time

  11. http://www.cdc.gov/niosh/images/99-143l.jpg User Seal Check • Positive pressure test – • Cup one hand under the component housing cover (not possible on all models) • Cover the exhalation valve vents with the other hand (not possible on all models) • Blow into the mask • Face blank should move away from face • Blow into the mask with exhalation uncovered and ensure it operates

  12. http://www.cdc.gov/niosh/images/99-143l.jpg User Seal Check • Negative pressure test • Use palms of hands to block filter air inlets (filter ports for mock-up) • Inhale gently, hold breath for 10 seconds • Face piece should collapse against face, and remain there

  13. Final Steps Before Entry • Ensure hood is around face-piece and fastened under the chin. • Secure the hood to the coveralls as needed with Velcro closure (tape for DOE).

  14. Doffing • Remove Outer Gloves • Remove Hood • Bend at the waist • Reach under mask at chin • Pull mask off of face at chin • Remove mask off the top of head – out and away • Disposition the mask as directed. • For the PE, bag the respirator across the SOP as coached by the Instructor.

  15. Air Sampling

  16. Filter Type Sampling • Most common form of air sampling • Air drawn through filter paper at known flow rate for known length of time • Many varieties • Sometimes taken in tandem with a chemical filter cartridge

  17. Basic Air Sampler

  18. http://www.fjspecialty.com/lv-14m.htm Air Samplers • Portable • Fixed • Contaminated area • Buffer area • Stack (effluent) • Incorporate monitor – detector looking at filter paper • Personal – breathing zone

  19. Personal Air Sampler (PAS) • Worn by worker • Breathing Zone sampler • Low flow – 2 L/m • Battery operated • Must be handled carefully to avoid contaminating filter

  20. Regulated Air Sampler (RAS) • Installed or portable • Low volume filter paper sampler < 7cfm • Used to verify containment integrity • Determine work place ambient radioactivity • Sample occupied areas

  21. In the Mock-Up

  22. High Volume Air Sampler(Staplex) • Short duration sampling • Area coverage • Job-site decisions • Accident coverage

  23. High Volume Air Sampler(Staplex)

  24. High Volume Air Sampler(Staplex)

  25. High Volume Air Sampler(Staplex) Flow Meter on the rear Read to the bottom of the ball

  26. Variable Flow Rate Air Sampler(Radeco) • Short duration sampling • Manual & Variable Mode • Area coverage • Job-site decisions • Accident coverage

  27. Variable Flow Rate Air Sampler(Radeco) Glass Fiber Filter paper “fuzzy side out

  28. Variable Flow Rate Air Sampler(Radeco) Flow Meter on Side Read to the bottom of the ball

  29. Air Sample Activity Calculation • Complete Air Sample Data Sheets • Calculate total volume (flow rate x time) • Count air sample filter with β-γfrisker and α frisker (quick count) • Prepare filter paper for isotopic analysis and delivery to the count room • Attach Air Sample Data Sheets to the Student Guide

  30. Scenario Brief • The 509 RCA posted as an airborne radioactivity area – respiratory protection required for entry. • A full set of PCs is required for entry into the 509 RCA. • Obtain two ten minute air samples • Exit the area remove respirator, PCs and bag material into the 508 room. • Count and calculate the activity for a quick count

  31. Other Instructions • This practical exercise may be completed individually, or with a partner except each partner must draw one air sample. • The calculation portion of the exercise must be performed independently. • Follow the instructions in the exercise guide. • Use disposable latex gloves for your outer set of gloves. • Wipe out the respirator with a sanitizing wipe prior to donning the mask and again after removal and prior to storing.

  32. Other Instructions • Do not separate this package. Maintain it intact. • Record all answers on the document – no extra pages. •  Return the RPT-243-PE-6 Practical Exercise Guide document to the instructor as directed.

  33. Time to DO!

More Related