1. Model common control system components.

INTRODUCTION TO CONTROL SYSTEMS. Course Objectives. 1. Model common control system components. 2. Select an appropriate control algorithm of PID type or one of its variations.

ermae
Download Presentation

1. Model common control system components.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. INTRODUCTION TO CONTROL SYSTEMS Course Objectives 1. Model common control system components. 2. Select an appropriate control algorithm of PID type or one of its variations. 3. Analyze the performance of a control algorithm using transfer functions, block diagrams, and computer methods, in light of given performance specifications. 4. Using MATLAB and Simulink to analyze and simulate control systems A control system consists of subsystems and plants for the purpose of obtaining a desired output with desired performance, given a specified input. A major aplication of the methods of system dynamics is the design of control systems.

  2. Basic Components of a Control System • Objectives of control (Inputs) • Control system components (Controller, plant, actuator, sensor,…) • Results (Outputs) Automobile : Sensors (Displacement,speed,force,pressure,temperature, fluid flow, fluid level voltage, current). Actuators (DC motors, step motors, pumps, heat sources) Home Heating System : Sensors (Temperature, pressure, fluid flow). Actuators (Motors, pumps, heat sources) Robot : Sensors (Optical image, displacement, speed,force, torque, pressure voltage, current). Actuators (AC motors, DC motors, step motors, hydroulic actuators) Control systems Open-loop control sytems Closed-loop control sytems

  3. Plant Plant Actuator Actuator Open Loop Control Systems: u v Input Output Sensitive to changing in parameters and disturbance. Closed Loop Control Systems: (Feedback Systems) Control (Actuation) Signal Sensing signal Disturbance Error u Reference + Output + + Controller Sensor - Error signal= Reference – Sensing signal

  4. Heater Examples of Control System Applications Heater Furnace Sensor Annealing Furnace Servo motors Washing machine Robots Home heating system Cruise control

  5. Home Heating Control System : Reference temp. Controller (Thermostat) Temperature Sensor : Measured temp. : Disturbance Control signal (heat transfer: door, window, wall, etc.) Fuel flow Heater Valve Error Status Control action Open valve Cold Hot Close valve Open Loop: Closed Loop: + Plant Temp. Sensor + + Controlller (Thermostat) Valve -

  6. Cruise Control System Usage in 1990’s Driver comfort Save fuel Road conditions Error signal Measured speed signal Fuel flow Vehicle speed Control signal Reference + + Motor and Powertrain system Speed Sensor Actuator(Valf) + Controller Speed -

  7. a) Mathematical model (Cruise Control System) : Fp: Pushing force (from engine) Fd: Distrubance (wind, gravity, enviromental factors, etc.) b) Closed loop control:

  8. Control Aplications with Industrial Robots Inverted pendulum control Ball grabber

  9. x Z

  10. V e x VrControl Input fd:Disturbance Vs:Response

  11. Free Body Diagrams: External forces, Joint forces, The Law of Action-Reaction

  12. V e P (Proportional) control:

  13. No Disturbance Kp Steady State Error Disturbance Fd=10N Kp constant, Steady State Error Disturbance Fd=10N Kp constant, Ki Steady State Error 0 No Disturbance Steady State Error Disturbance Fd=10N Kp constant, Ki constant, Kd Overshoot Vibrations

  14. clc;clear;close all m=100; c=4; k=4000; Ka=3e-2; Ks=100; Kp=10;Ki=5;Kd=0;kz=0.01; kfd=10; %Kp=0 to get open loop response. nho=Ka*Ks*[c,k];dho=[m,c,k];nhdo=Ks; nc=[Kd,Kp,Ki];dc=[1 0]; if Ki==0; nc=[Kd Kp]; dc=1; end %% n1=1; d1=[m,c,k]; nh=Ka*Ks*conv(nc,[c,k]);nhd=Ks*dc; dh=conv(dc,d1);dh=polyadd(dh,nh); sys1=tf(nh,dh); sys2=tf(nhd,dh); syso=tf(nho,dho); sysd=tf(nhdo,dho); p=roots(dh);p0=p(1);cksi dt=0.001;tson=50; t=0:dt:tson; [c1,t]=step(sys1,t); [c2,t]=step(sys2,t); c=kz*c1+kfd*c2; co=step(syso,t);cd=step(sysd,t); co=kz*co+kfd*cd; if Kp==0; plot(t,co) %Open Loop Response else plot(t,c) %Closed Loop Response end