120 likes | 346 Views
YL9300 HPLC System. Compact & Perfect for Your Satisfaction. YL9300 HPLC Features. Compact Design Perfect Performance Impact to competitors. YL9300 HPLC Features. Compact Design Integrated LPG HPLC system : Vacuum Degasser + Quaternary Pump + UV Detector Easily upgraded parts
E N D
YL9300 HPLC System Compact & Perfect for Your Satisfaction
YL9300 HPLC Features • Compact Design • Perfect Performance • Impact to competitors
YL9300 HPLC Features Compact Design • Integrated LPG HPLC system • : Vacuum Degasser + Quaternary Pump + UV Detector • Easily upgraded parts • : For wide wavelength range :190~900 nm (Standard:190~600 nm) • : For wide flow rate rage : up to 10 ml/min (Standard: up to 5 ml/min ) • Simple Maintenance • : Pump & Vacuum Degasser modules in a sliding drawer
YL9300 HPLC Features Perfect Performance • Increased mobile phase composition efficiency • : Stable supply of mixed mobile phases through shock-resistant SUS • tubing and low pump head volume • : Pump on the bottom to strengthen suction force of pump • Decreased solvent peak influence • : New focus lens in a monochromator reducing mobile phase RI effect • Narrow spectral bandwidth Greatly stabilized baseline with substantially minimized noise level
YL9300 HPLC Features Decreased solvent peak influence in comparison “A” HPLC Analysis Condition Mobile Phase : Water:MeOH=65:35 Wavelength : UV detector 550 nm Injection Volume : 100 ul Sample : Cyanocobalamin (Vitamin B12) Solvent Peak YL9300 HPLC
YL9300 HPLC Features Impact to competitors • Competitive or even lower price than others • High speed data process by network (LAN) communication • Low maintenance cost • : Integrated power board, SMPS & fan for 2 modules • : Simplicated each part • Modern injector bracket to install 2 manual injectors & • 2 column switching valves
YL9300 HPLC Specification Vacuum Degasser • Number of channel: 4 CHs • Maximum flow rate: 10 ml/min per channel • : 70% of Gas Removal in Methanol at > 0~2.0ml/min per channel • Internal volume per channel: 925ul per channel • Materials in contact with solvent: Teflon AF, PEEK and • Glass-filled PTFE • Safety & maintenance: Error detection
YL9300 HPLC Specification Quaternary Pump • Compressibility compensation: Automatic • Flow range: 0.001-5ml/min (Standard) • 0.001-10ml/min (Option) • Flow rate accuracy: ≤±1% at 1ml/min • Flow rate precision: <0.1% RSD at 1ml/min • Number of eluent lines: 4 • Composition precision: <0.1% • Composition accuracy : <0.5% • Manual prime-purge(Standard) / Auto prime-purge(Option)
YL9300 HPLC Specification UV/VIS Detector • Wavelength range: 190~600 nm (Standard) /190~900nm (Option) • Data collection rate: up to 50Hz • Light source: Deuterium arc lamp • Tungsten lamp addible for visible range (Option) • Bandwidth: 5 nm • Wavelength accuracy: ±1 nm • Wavelength precision: ±0.1nm • Linearity: >99.5% at 2.5 AU (acetone, 254nm) • Noise level: <±0.35 X 10-5 Abs/min, 254nm, dry cell • Drift : <1 X 10-4 Abs/hour
YL9300 HPLC Specification System Information • Communications: LAN • Dimensions: 375 X 470 X 545mm (width X height X depth) • Weight: 27 Kg • Safety & maintenance: Leak detection, Diagnostics, • Error detection • Line Voltage: 100-240VAC, ±10% • Line frequency: 50/60Hz, ±5% • Power consumption : 150W