1 / 19

CTF3 RESULTS – 1 ST RUN 2004 (7th JUNE – 16th JULY)

CTF3 RESULTS – 1 ST RUN 2004 (7th JUNE – 16th JULY). Outline. Review of planned strategy, schedule and objectives Main results Overview of run history & main problems encountered What has been left out… Highlights on hardware, beam studies and 30 GHz production. 1. 2. 3. 4. 1. 2. 3.

ethan
Download Presentation

CTF3 RESULTS – 1 ST RUN 2004 (7th JUNE – 16th JULY)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CTF3 RESULTS – 1ST RUN 2004 (7th JUNE – 16th JULY) Outline • Review of planned strategy, schedule and objectives • Main results • Overview of run history & main problems encountered • What has been left out… • Highlights on hardware, beam studies and 30 GHz production

  2. 1 2 3 4 1 2 3 4 STAGES • Several “stages” depending on the dump where the beam is sent. • Allows operation in parallel to RF conditioning Need MKS02 & MKS03 Need MKS05 & MKS06 Need MKS11 & MKS12

  3. 1 2 3 4 SCHEDULE RESERVE HB FT RC HB FT RC

  4. CTF3 COMMISSIONING PROGRAM 1st RUN (7th JUNE – 16th JULY) Main Goals: • Commission hardware & software modified since last year ( up to girder 8 ) • Set-up beam transport (power mode) through PETS line • Check 30 GHz power production in PETS line • Commission new hardware (after girder 8) • Nominal beam transport to dump in girder 13

  5. 30 GHz RF POWER PRODUCTION Beam transport in PETS line – final results 18 July 2004 Expected power from current measured before PETS (F=1) Expected power from current measured after PETS (F=1) Measured 30 GHz power

  6. NOMINAL BEAM TO DUMP 13 I [A] x,y [mm] Aug 2003 Nov 2003 July 2004 Nominal current – 3.5 A z [m] z [m] MAGNETIC CHICANE PETS LINE INJECTOR SPECTRO 7 DUMP 13

  7. RUN OVERVIEW 3.3  3 A PETS 2.5 MW Problems with water distribution, leaks etc.. Problems with MKS06 (controls, power supplies, breakdowns…) and with MKS11 (breakdowns) NOMINAL RF in 02,03 0.4  0.2 A PETS NOMINAL BEAM TO DUMP 13 0.4 A , 90% PETS FIRST BEAM MACHINE CLOSED FIRST 30 GHz POWER 1 A , 70% PETS

  8. (Some) activities during RF conditioning • RF pulse compression system: • Signals calibration (MW scale) not yet completed • Remote temperature control ? • RF pulse shaping OK • Magnets: • Check stray fields around gun (solenoids on) OK • Polarity check OK (but not everywhere…) • Others: • Set-up software interlocks OK ? • …

  9. 1 STAGE 1 3 1 6 5 2 4 7 • Modified hardware & software, instrumentation: • Gun pulser timing (short pulse length) NO • BPEs increased bias (avoid charging-up & signal drift) Tried – does not work • MTV 165 CCD camera, Proxitronic control OK , NO • PB1 disconnected OK • BPR 290 ADC calibration, waveguide NO, OK • MTV 440 (spectrometer) OK • Segmented dump in spectro OK • Beam studies: • Beam tranport in solenoid (behaviour of corrector 120, elliptical beam/coupling, beam oscillations) NO

  10. STAGE 2 5 1 4 6 2,3 2,3 7 • Modified hardware & software, instrumentation: • BPR 475 ADC calibration, waveguide NO, OK • WCM 490, WCM 725 (influence of corrector, dep. on position) NO ? • Machine protection system (based on WCMs) First tests • MTV 500 OK • MTV 730 OK • MTV 750 (spectrometer) OK • Segmented dump in spectro OK • Beam studies: • Transverse optics (re-match from last year quad scans, new quads scans in MTV 730, iteration…) Quad scan only • Identify RF crest (beam loading vs. BPR wguides) NO + bunch compression Not full study • Establish PETS pilot beam (200 mA, 200 ns) OK • Establish power mode beam (minimum bunch length) OK (not max 3 GHz power)

  11. STAGE 3 2 3 1 1 1 • New hardware & software, instrumentation: • BPMs 115, 240, 280 OK • BLM system OK • 30 GHz signal acquisition OK • Beam studies: • Set-up dispersion in PETS line (BPMs) OK (qualitative) • Pilot beam momentum optimization (clean transient in chicane, minimize transient from MKS 05 & MKS 06, measure spread in BPM115) Not complete • Pilot beam through PETS OK • Raise current, power mode beam through PETS (monitor vacuum, 30 GHz power, BPMs, BLMs) OK • Beam phase swing for pulse compression NO

  12. STAGE 4 2 ? 1 1 1 1 3 • Modified hardware & software, instrumentation: • BPMs 990, 1090, 1190, 1290 OK • New BLM chambers ? Tested – did not work • Extend automatic steering ? NO • Beam studies: • Transport nominal beam to final dump OK

  13. 28 June 2004 Steering also in solenoidal region AUTOMATIC BEAM STEERING 1

  14. AUTOMATIC BEAM STEERING 2 30 June 2004 Steering also in PETS

  15. RF PULSE COMPRESSION – PHASE PROGRAM

  16. Transient Full beam SEGMENTED BEAM DUMP 16 July 2004 – during quad scan

  17. QDC 705 QFC 710 Reference plane MTV 726 QUAD SCAN - EMITTANCE 16 July 2004

  18. I [A] sY sX with dispersion ( sp = 1% ) Z [m] MAD MODEL RESULTS – PETS LINE Running conditions of 16 July 2004 – before quad scan – E = 43.8 MeV

  19. 30 GHz RF – PETS “CONDITIONING”