Invisible Service Technicians, LLC

Invisible Service Technicians, LLC. Invisible Service Technician Monitor Activation Process: IST MaintSelectionV3.php. Setup August 2006. 1) Sales Order Procedure-see DN1040. 2) Product Shipped. 3) IST Installed . 4) IST Calls Collection Server. 5) Data Center Updated.

Download Presentation

Invisible Service Technicians, LLC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Invisible Service Technicians, LLC Invisible Service Technician Monitor Activation Process: IST MaintSelectionV3.php. Setup August 2006

  2. 1) Sales Order Procedure-see DN1040 2) Product Shipped 3)IST Installed 4)IST Calls Collection Server 5) Data Center Updated 10) Enter “Monitored Equipment” (Data Center) 7) Enter “Installation information” (Data Center) 8) Create Customer (Profile Management) 7) Create Contractor (Profile Management) 6) Contractor sends Info.-see DN1008, 1009 & 1011 11) Complete “Sensor Edit” (Data Center) 12) Complete “Sensor Mapping” (Data Center) 13) Enter “Viewing Privileges” (Data Center) 14) Enter “Alert Recipients” (Data Center) 15) Edit General Tab (IST Maint.) 20) Edit Accumulator Tab (IST Maint.) 19) Edit Calculations Tab (IST Maint.) 18) Edit Digital Sensors Tab (IST Maint.) 17) Edit Thermo. Sensors Tab (IST Maint.) 16) Edit Temp Sensors Tab (IST Maint.) 21) Edit Cycles Tab (IST Maint.) 22) Edit Alarms Tab (IST Maint.) Monitor Configuration

  3. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Always select and press “Update IST Initial Setup” button to save modifications made to viewed section, if not when you select and move to other tabs the section will return to previous settings. Op Delay Name = Short name on board. Sensor = Digital or Thermo sensor used to trigger delay. State = Binary state of sensor to cause trigger of delay 1= closed 0= opened. Delay = Delay time in minutes. Outdoor Temperature Sensor: By default the OAT sensor is set to “Temp6”. The OAT sensor is used for on the board calculations of Heat days and Cool days. LED On = 0 LED Off = 9 LED Flashing = 10 Photo Cell Open = off NO = LED off Photo Cell Closed = on NC = LED on Flash Code 1 By default is set to Control 1 (Reader 1) Digital 5 Set the Code 1 and Code 2 to the normal condition of LED Flash Code 2 By default is set to Control 2 (Reader 2) Digital 6 General Tab:IST Maint SETUP

  4. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Short Name: Displayed on board Long Name: Displayed on Reports, and Data Center Secondary min/max temperature 2 Lim Src = Digital, or Thermo source to trigger 2 min/max. 2 Lim Stat = Condition of source to cause trigger of 2 min/max. Delay = Source trigger delay in minutes. 2 min/max Delay and Op Delay work in parallel. They initiate at same time. Ability to Enable or Disable installed Temperature sensor. Indicates sensors that have been checked as installed on Data Center. Temp Sensors:IST Maint SETUP

  5. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Conditional Logic for sensors: Dep * Stat on, off Dep Op or, and Logic Statement includes: (Op delay, Dep 1 Src, Dep 1 Stat, Dep Op, Dep 2 Src, Dep 2 Stat) This statement has to be True before the initiation of alarm. Dep 1 Src and Dep 2 Src Select options: Digital sensors (Digital1- Digital8) Thermo sensors (Thermo1- Thermo8) Temp Sensors:IST Maint SETUP

  6. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Thermo sensor inputs offer status of thermostat operating condition. Wiring is paralleled off thermostat terminal strip. (G,Y1,Y2,W1,W2,REV,E) Thermo sensors detect the presence of applied 24v + off T-Stat. If using a Thermo sensor to detect status from relay ensure that 24v+ is applied to input and that the voltage originates from same control transformer providing power to monitor. Must share same common. Thermo sensors must be wired and set to “Enabled NO” to trigger accumulator. Thermo. Sensors:IST Maint SETUP

  7. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Enabled Enabled NO Enabled NC Disabled Spare Thermo sensor (Aux3) Thermo sensor status is immediately indicated by monitor, the delays and dependencies only affect output to Alarm. Thermo. Sensors:IST Maint SETUP

  8. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 • Enabled • Flash Cde Det • Enabled NO • Enabled NC • Disabled • When selecting “Flash Cde Det” for enabled condition you must perform the following: • Set normal conditions of LED “General” tab. • LED on = 0 • LED off = 9 • LED Flashing = 10 • Flash code descriptions and alert condition (If alert is to be sent for 1 or all flash counts) “Data center”. • Enable alarm for specific Digital “Alarm” tab. Short Name: 8 characters, used on board. Long Name: 50 characters, used in Data center, & Reports. Digital Sensors:IST Maint SETUP

  9. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Digital sensors can be set to either “Enabled NC” or “Enabled NO” to trigger accumulator. Digital sensor status is immediately indicated by monitor, the delays and dependencies only affect output to Alarm. Digital Sensors:IST Maint SETUP

  10. Op Delays are Dependent upon power being applied to one of the following: Y1, Y2, W1, W2 Src 1, Src 2 Selections available are Temp sensors, and Calculations that have been defined with short Name. Operator Math functions available (Add, Subtract, Multiply, and Divide). 2 min/max Ability to apply 2 min/max temp values for alarm output. Logic Statement These statements operate the same in all tab’s and must always be True before alarm is issued. Enable or Disable Calculation Calculations:IST Maint SETUP

  11. Accumulators Accumulators track run minutes of applied source. Accumulated minutes are sent each transmission and reset to 0 on board after completion of transmission. Source Selections available are Digital and Thermo sensors. Accumulators:IST Maint SETUP

  12. Cycles This function counts the cycles (on / off) of source. Cycles are sent each transmission and reset to 0 on board after completion of transmission. Source Selections available are Digital and Thermo sensors. Cycles:IST Maint SETUP

  13. Primary min/max Temperatures Secondary min/max Temperatures 2 min/max Temps are triggered by Digital or Thermo sensors located in “Temp Sensor”, and “Calculation” sections. Min Max Alarm Enable or Disable Alarm output for both primary and secondary min/max temperatures. Alarm Section Alarm section is dependent on Logic statement for each sensor (device) being True before issuing alert. Refer to Calculations tab (last 5 options: Dep 1 Src, Dep 1 St, Dep Op, Dep 2 Src, Dep 2 St) Alarm Text Message Enable or Disable Text Message Alarms:IST Maint SETUP