1 / 13

Robo-AO Overview: System, capabilities, performance

Robo-AO Overview: System, capabilities, performance. Christoph Baranec (PI). Why Robo-AO?. Robotic – high efficiency observing Laser Guide Star – high sky coverage Adaptive Optics – spatial resolution set by D Small Telescopes – lots of available time. Robo-AO at the P60. Robotic.

evers
Download Presentation

Robo-AO Overview: System, capabilities, performance

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Robo-AO Overview:System, capabilities, performance Christoph Baranec (PI)

  2. Why Robo-AO? Robotic – high efficiency observing Laser Guide Star – high sky coverage Adaptive Optics – spatial resolution set by D Small Telescopes – lots of available time

  3. Robo-AO at the P60

  4. Robotic Reed Riddle (software lead) to fill in details following this presentation…

  5. Laser guide star • Rayleigh LGS (e.g. Starfire, Mt. Wilson, MMT, WHT, SOAR, LBT?) • Range gated – 650 m at 10 km – mV~9 • On/off operation • More robust operation in presence of clouds/haze • Waived by FAA – no human spotters required • Interface with USSTRATCOM • Send them target list 3-4 days prior to lasing • Will receive list of ‘open windows’ for each target

  6. AO system • High order wavefront will be measured by laser and corrected by deformable mirror • Stellar image motion captured by one of the science cameras and used to drive tip/tilt corrector • Single atmospheric dispersion corrector for both science instruments (not UV)

  7. Visible science instrument • Andor iXonEM+ DU-888 • Electron Multiplying CCD • 1024 x 1024 pixels • 44” x 44” square FoV • 0.043” pixels (Nyquist at λ = 620 nm) • Full frame rate: 9 Hz • Sub frame rate: ~200 Hz

  8. Baseline NIR camera: InGaAs • InGaAs – (Xenics: Xeva) • Delivery in 8 weeks from order • 0.9-1.7 μm sensitivity • 180 e- read noise • 7000 e-/s dark current • ~200k e- full well • 320 x 256 pixels (0.062”/pixel Nyquist λ = 900 nm) • ~20 x 16 arc sec field Xeva-1.7-320

  9. Ideal (future?) NIR camera • HgCdTe – (Teledyne: H2RG) + 2’ FoV, 0.062” pixels (Nyquist at λ = 900 nm) + Excellent noise + Flexible readout – integrating while T/T guiding • Cost – no $$ yet… • Development time

  10. Likely initial observing modes • Infrared Science: • Tip/tilt sensing with visible, integrate on IR camera • Visible Science: • Fast readout of visible camera - Lucky imaging/post facto shift and add • H2RG will give additional capability

  11. AO capabilities – quick answer • ~Diffraction-limited resolution visible • 0.5+ Strehl in the NIR • General imaging Range of: filters, exposure times, camera setup

  12. Error budget Assuming mV=17 T/T star

  13. Performance – H-Strehl • mV < 15 dominated seeing, HO errors. mV > 19 dominated T/T errors • Greater than 40% Strehl with mV = 19 T/T in median conditions • FWHM at H < 0.26” in even 75% worst seeing conditions *At Zenith

More Related