110 likes | 117 Views
The real and reliable PassQuestion Using HPE OneView HPE2-T36 Questions and Answers will enable you to get through your exam in just your first attempt without any problem.
E N D
HPE2-T36 Free Questions HPE2-T36 Free Questions Using HPE OneView Using HPE OneView https://www.passquestion.com/ https://www.passquestion.com/HPE2-T36 HPE2-T36.html .html
Question 1 Question 1 What is the earliest Server generation supported in HPE OneView for Secure Boot What is the earliest Server generation supported in HPE OneView for Secure Boot configuration within the Server Profile Template? configuration within the Server Profile Template? A. Gen7 A. Gen7 B. Gen9 B. Gen9 C. Gen10 C. Gen10 D. Gen8 D. Gen8 Answer: B Answer: B
Question 2 Question 2 Your customer reports receiving an error after re-configuring some uplink sets. The error Your customer reports receiving an error after re-configuring some uplink sets. The error states that their Logical Interconnects are non-compliant with the Logical Interconnect states that their Logical Interconnects are non-compliant with the Logical Interconnect Group. Group. What must they do to clear this error? What must they do to clear this error? A. Delete the affected Logical Interconnect Group and recreate it. A. Delete the affected Logical Interconnect Group and recreate it. B. Go to HPE OneView Dashboard to acknowledge the error. B. Go to HPE OneView Dashboard to acknowledge the error. C. Update the Enclosure Group configuration with the new uplink set information. C. Update the Enclosure Group configuration with the new uplink set information. D. Go to Logical Interconnect and select "update" from the group options. D. Go to Logical Interconnect and select "update" from the group options. Answer: D Answer: D
Question 3 Question 3 You need to add an HPE ProLiant DL380 Gen10 server to the HPE OneView appliance for You need to add an HPE ProLiant DL380 Gen10 server to the HPE OneView appliance for monitoring. monitoring. Which information is required to complete this task? (Choose two.) Which information is required to complete this task? (Choose two.) A. HPE OneView Advanced license A. HPE OneView Advanced license B. firmware baseline B. firmware baseline C. iLO IP address C. iLO IP address D. Enclosure Group name D. Enclosure Group name E. iLO credentials E. iLO credentials Answer: A,B Answer: A,B
Question 4 Question 4 Which enhanced security feature is unavailable within HPE OneView? Which enhanced security feature is unavailable within HPE OneView? A. configure firewall rules A. configure firewall rules B. role-based access control B. role-based access control C. two-factor authentication C. two-factor authentication D. SNMP v3 D. SNMP v3 Answer: A Answer: A
Question 5 Question 5 A customer has a strict change control environment. A customer has a strict change control environment. How do Server Profile Templates help with change control policies? How do Server Profile Templates help with change control policies? A. They allow users to define configurations once and within minutes. A. They allow users to define configurations once and within minutes. B. They help to monitor, flag, and update server profiles in HPE OneView. B. They help to monitor, flag, and update server profiles in HPE OneView. C. They allow server profile mobility. C. They allow server profile mobility. D. They provision hardware quickly. D. They provision hardware quickly. Answer: B Answer: B
Question 6 Question 6 You are designing a new deployment consisting of HPE Proliant Gen10 rack servers and a Nimble You are designing a new deployment consisting of HPE Proliant Gen10 rack servers and a Nimble storage array. storage array. Which data protection method is recommended to back up and be able to restore your appliance in Which data protection method is recommended to back up and be able to restore your appliance in case of a catastrophic failure? case of a catastrophic failure? A. Create regular backup files and store them to an off-appliance location A. Create regular backup files and store them to an off-appliance location B. Deploy two virtual appliance and enable synchronous replication B. Deploy two virtual appliance and enable synchronous replication C. Perform regular Snapshot of the virtual appliance on the HPE Nimple array. C. Perform regular Snapshot of the virtual appliance on the HPE Nimple array. D. Configure automatic VMware snapshot of the virtual appliance. D. Configure automatic VMware snapshot of the virtual appliance. Answer: A Answer: A
Question 7 Question 7 An administrator selected “firmware and OS drivers using smart update tools” when An administrator selected “firmware and OS drivers using smart update tools” when installing a new HPE Service pack for ProLiant. installing a new HPE Service pack for ProLiant. Which statement are true for the is administrator environment? Which statement are true for the is administrator environment? A. Customer will be automatically detected and updated simulteniously. A. Customer will be automatically detected and updated simulteniously. B. By default only a new version of firmware/drivers will be installed B. By default only a new version of firmware/drivers will be installed C. Firmware and OS drivers will always start immediately to be as fast as possible. C. Firmware and OS drivers will always start immediately to be as fast as possible. D. Firmware and OS drivers are updated without powering off the server hardware D. Firmware and OS drivers are updated without powering off the server hardware Answer: D Answer: D
Question 8 Question 8 You remove an HPE SY480 compute module from its bay and install a host bus adapter (HBA) into You remove an HPE SY480 compute module from its bay and install a host bus adapter (HBA) into the compute module. When you install the module back into its original bay you notice that the the compute module. When you install the module back into its original bay you notice that the server profile in HPE OneView is showing “unassigned”. server profile in HPE OneView is showing “unassigned”. What is the reason for this? What is the reason for this? A. There is no connection configured for the HBA in the “Connections” section of the Server A. There is no connection configured for the HBA in the “Connections” section of the Server profile. profile. B. The server hardware type is invalid. B. The server hardware type is invalid. C. The Server Profile is inconsistent with its Server Profile Template. C. The Server Profile is inconsistent with its Server Profile Template. D. The Affinity is configured to “Device bay + hardware”. D. The Affinity is configured to “Device bay + hardware”. Answer: B Answer: B
Question 9 Question 9 When creating a Server Profile Template, what are advantages or creating an unassigned Ethernet When creating a Server Profile Template, what are advantages or creating an unassigned Ethernet type connection during template creation? (Choose two.) type connection during template creation? (Choose two.) A. It enables auto-zoning of SAN connections A. It enables auto-zoning of SAN connections B. It avoids re-enumeration when assigning a network to existing connections B. It avoids re-enumeration when assigning a network to existing connections C. It eliminates the need to power off the server when adding connectivity to the production C. It eliminates the need to power off the server when adding connectivity to the production networks or disabling a profile connection networks or disabling a profile connection D. Template creation is the only time that new network adapters can be created D. Template creation is the only time that new network adapters can be created Answer: B,C Answer: B,C
Question 10 Question 10 After assigning a server profile to an HPE ProLiant blade, you notice that the serial number being After assigning a server profile to an HPE ProLiant blade, you notice that the serial number being reported on the server profile page is not the one that matches the label on the server. reported on the server profile page is not the one that matches the label on the server. You want the reported serial number to match the label. You want the reported serial number to match the label. What do you need to do? What do you need to do? A. Create a new Server Profile and go to the “Advanced” section, then change the radio button for A. Create a new Server Profile and go to the “Advanced” section, then change the radio button for the serial number/UUID from “Virtual” to “Physical” and apply it to the server. the serial number/UUID from “Virtual” to “Physical” and apply it to the server. B. Edit the Server Profile and go to the “Advanced” section, then change the radio button for B. Edit the Server Profile and go to the “Advanced” section, then change the radio button for serial number/UUID from “Virtual” to “Physical”. serial number/UUID from “Virtual” to “Physical”. C. Create a new Server Profile Template and go to the “Advanced” section, then change the radio C. Create a new Server Profile Template and go to the “Advanced” section, then change the radio button for the serial number/UUID from “Virtual” to “Physical”. button for the serial number/UUID from “Virtual” to “Physical”. D. Edit the Server Profile and go to the “Advanced” section, then change the radio button for D. Edit the Server Profile and go to the “Advanced” section, then change the radio button for serial number/ UUID from “Virtual” to “Physical” and enter the serial number. serial number/ UUID from “Virtual” to “Physical” and enter the serial number. Answer: D Answer: D