An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wire Scanner and BSRT status • F.Roncarolo, E. Bravin, A. Rabiller • S. Bart Pedersen, A. Guerrero • J.Emery, M. Sapinsky • LHC BOC, 15-March-2011

  2. Wire Scanners • Quite some work done on software and hardware • Standard mode (40 MHz bunch-to-bunch) • Electronics installed on all devices and commissioned (J.Emery) • FE setup for synchronizing bunch selection (A.Guerrero) • OP GUI: few bugs corrected, new PRO version released (E.McCrory, T.Lahey) • Beam1: 200 Hz baseline noise on PM signal to be cured (J.Emery, TechStop) • Turn Mode (~ 10us Averaging) • B1 needs new delay w.r.t. turn clock to be adjusted in order to open gate at bucket 1 • B2 OK • General • FE fits (sent to Logging DB) to be checked (anyhow all profiles logged, Offline fit always possible) • Need MD to study absolute accuracy

  3. WS B1

  4. WS B2

  5. BSRT Hardware • During shut-down (A.Rabiller et al.) • Optical path re-alignment • Slow camera translation stage for additional remote focusing degree of freedom • Intensified Fast Camera installed • Alignment to be further improved (especially B1) as soon as new external lasers delivered • Fast Camera Ethernet connection not stable yet

  6. BSRT Software/Control • Front End (A.Guerrero) • Automatic optical filters and camera gain settings based on image acquisition feedback • DONE  get rid of theoretical tables vs beam energy&intensity • Automatic entrance mirror steering based on image acquisition feedback • Almost DONE can automatically look for best focus vs beam energy • BI Expert GUI (S.Bart Pedersen, E.Bravin) • subscription to FBCT  bunch lists • on demand bunch scans • Scan dies as GUI closed • OP Fixed Display (L.Ponce) • OP GUI (LAFS: Dennis Nicklaus) designed at early BSRT stage • Nobody using it • LAFS personnel (McCrory, Nicklaus, et al) are ready to modify/upgrade

  7. BSRT software NEXT • Front End • Fully commission and test stability of automatisms based on feed-back • Major upgrade: move profile fits from FE to daemon process on US45 PC (already used for automatic controls) • Bunch Scans (Front End and/or GUIs) • Short termEquip FE with FBCT subscription and automatically initiate scans ? • Upgrade OP Gui for bunch scans? Who?

  8. BSRT calibration • Preliminary results of cross-calibration w.r.t. WS • Camera translation allows to find a better focusing than last year • We will compute best correction factors vs energy and publish to logging • Many studies still needed to understand absolute accuracy • Focusing • Aberration (geometric,chromatic) • Diffraction Corr Factors 2010 2011 (prelim.)

  9. BSRT vs WS (preliminary)

  10. BSRT vs WS (preliminary)

  11. CONCLUSIONS • WS • 40 MHz operational • Absolute calibration to be studied • Need TS to investigate noise on B1 WS H and V • BSRT • automatisms for gain, focusing, steering almost all done, stability to be tested • absolute calibration to be studied • Bunch-to-bunch scans not automatic, need some more effort BI and OP • FAST camera (bunch-to-bunch, turn-by-turn) commissioning hopefully after TS • MD requests • ramp 1.38TeV (includes AGAP and LDM) • WS-BSRT cross-calibration • WS response to PM gain/ filters • Emittance preservation • General • Check beam optics at monitors