AMBRA PASCAL. Hybrid. Twisted pair power lines: - 4 pairs for PASCAL chips - 3 pairs for AMBRA chips - 1 pair for CARLOS, GOL, TTCrx Common shield Grounding near the detector. End-ladder boards: LV rad-hard regulators for PASCAL (each hybrid) for AMBRA (each hybrid)
E N D
AMBRAPASCAL Hybrid • Twisted pair power lines: • - 4 pairs for PASCAL chips • - 3 pairs for AMBRA chips • - 1 pair for CARLOS, GOL, TTCrx • Common shield • Grounding near the detector • End-ladder boards: • LV rad-hard regulators • for PASCAL (each hybrid) • for AMBRA (each hybrid) • for CARLOS and GOL • for TTCrx SDD LVPS (1) Layer 4: 22 ladders with 8 detectors Layer 3: 14 ladders with 6 detectors General system configuration Section 1 Section 2 F. Tosello – June 26, 2001
SDD LVPS (2) Power required at the half-ladder (for layer 4) PASCAL chips :10.1 W (average), 20.1 W (peak, duty cycle 10%) AMBRA chips : 5.1 W (average), 15.2 W (peak, duty cycle 10%) end-ladder chips : 6.3 W (average) Total : 21.5 W (average), 41.7 W (peak, duty cycle 10%) Voltage & current per LVPS section (for layer 4) All chips but TTCrx require 2.5 V, TTCrx needs 3.3 V Rad-hard voltage regulator drop : assumed = 1 V PASCAL chips : 3.0 A (average), 5.8 A (peak, duty cycle 10%) AMBRA chips : 1.5 A (average), 4.4 A (peak, duty cycle 10%) end-ladder chips : 1.5 A (average) Max deliverable power per LVPS section: 52.5 W Power module efficiency : 75 % F. Tosello – June 26, 2001
SDD LVPS (3) Power cable & cross sections Every power supply line: 1-4 twisted-pairs (Jmax 3 A/ mm2) return lines grounded near the end-ladder with a low resistance The pairs supplying an end ladder have a common shield, grounded near the end-ladder each conductor is currently proposed to be AWG20 (0.5 mm2), 8 pairs / end-ladder are needed (e.g. 04.21.52.130.6, Ø EXT.=13.5mm) Power dissipation on cables (both conductors) / end-ladder for the PASCAL chip lines (4 pairs) : 0.31 W/m for the AMBRA chip lines (3 pairs) : 0.24 W/m for the end-ladder chip lines (1 pair) : 0.08 W/m Sense cables 3 small cross-section twisted-pairs / end-ladder F. Tosello – June 26, 2001
SDD LVPS (4) Rack space required for power supplies 5 crates: chassis Europa 6U + 2U fans (CERN soecs. N.385) Total of 36 modules,8 modules per crate Special requirements on PS inputs Mains: 1200 VA per crate Communications: CAN and RS232 Contacts/developments under way Development & production by Czech company AREM PRO (http://hp.ujf.cas.cz/alice/lvps/lvps.html) General features of the controls set & read : voltages, high and low current limits, currents, temperatures; switch on/off Possibilities: CAN and RS232, expectation: OPC server for TCP/IP F. Tosello – June 26, 2001
SDD LVPS (5) Test results (http://hp.ujf.cas.cz/alice/lvps/tests.html) Long term (3 months) test with dummy loads: stable operation at max loads Ripple in specs: 4 mV-pp @ VLOAD = 4V ILOAD 2.76 A Test with OLA chips in Torino: good floating characteristics Test on beam with prototypes of the final FEE ongoing at PS in these days F. Tosello – June 26, 2001