1 / 27

Module 11 PS M4110 Management

Module 11 PS M4110 Management. <Place supporting graphic here>. Module Objectives:. Connect using each of the four management methods Connect the PS-M4110 to different fabrics Describe the difference between the in band and out of band deployment methods

faolan
Download Presentation

Module 11 PS M4110 Management

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Module 11 PS M4110 Management <Place supporting graphic here>

  2. Module Objectives: • Connect using each of the four management methods • Connect the PS-M4110 to different fabrics • Describethe difference between the in band and out of band deployment methods • Joining a Multi-member Group using External Arrays

  3. Connect To PS-M4110

  4. There are four management methods used to connect to a member. 1 Group Manager 2 Serial Console Ports 3 Telnet / SSH 4 M1000e CMC / iDRAC

  5. Connect To M4110 iDRAC via CMC • M1000e CMC Login • Default login=root • Default password = calvin • No O/S required • No agents to install

  6. Telnet to CMC • Telnet to the IP address of the CMC and login

  7. Connect To PS-M4110 • Connect to the iDRAC port of the PS-M4110 with a RACADM command • Connect server-x (x=slot number) • Login to the member to issue PS-Series cli commands

  8. Fabric Selection

  9. Change the Fabric • If the member is already installed you can change the fabric it communicates on.

  10. Configure Array • Click configure array to change the fabric

  11. Select the Fabric • Select the fabric and click apply

  12. Labs: Lab 7 - PS-M4110 Initial Configuration Using the CMC GUI Lab 8 - PS-M4110 Initial Configuration Using the CMC Port Utility Lab 9 – PS-M4110 Configuration Options

  13. Management Network

  14. PS-M4110 Management Network • When configured only accessible through the CMC network

  15. In-Band Deployment/ManagementNew – CMC setup option External EqualLogic Group SAN Port • M4110 deployed from CMC Console Interface – Management Workstation • M4110 managed from EqualLogic Group Manager - Host Server 1 2

  16. Out of Band Deployment/ManagementNew – CMC setup option External EqualLogic Group Management Port SAN Port • M4110 deployed from CMC Console Interface – Management Workstation • M4110 management port enabled from CMC RACADM – Management Workstation • M4110 managed from EqualLogic Group Manager – Management Workstation 1 2 3

  17. Managing the Array with Group Manager and Multi-Member Groups

  18. Managing the Array with Group Manager • Managing a PS-M4110 array using the same tools as other arrays. • Familiar tools and process as all PS series arrays

  19. Group Manager GUI Requirements • Optimum screen size at least 1024 x 768 screen resolution • Browsers supported • Internet Explorer 6.0 or higher • Firefox 3.6 or higher • Safari 5 or higher • Google Chrome12 or higher • Requires Oracle (Sun) Java 1.6.x (java6) or 1.7.x higher (java7)

  20. Group Administrative Configuration tabs • General • Administration • Notifications • iSCSI • SNMP • VDS/VSS • Defaults • Firmware • Advanced

  21. Multi-Member Groups

  22. PS-M4110 Group • The PS-M4110 can join a Group within the M1000e chassis or External to the chassis

  23. PS-M4110 Without ToR • The PS-M4110 can join a Group outside the M1000e chassis External EqualLogic The external member is connected to the IOM switch’s in the M1000e chassis m1000e Stacked IOMs

  24. PS-M4110 With ToR External EqualLogic • The PS-M4110 can join a Group outside the M1000e chassis Stacked ToRs The external member is connected to the IOM switch’s outside of the M1000e chassis Ethernet LAN VLT LAG m1000e Stacked IOMs

  25. Module Summary • Now that you have completed this module you should be able to: • Connect using each of the four management methods • Connect the PS-M4110 to different fabrics • Describethe difference between the in band and out of band deployment methods • Using Group Manager • Joining a Multi-Member Group

  26. Lab: Lab 10 – Converged Infrastructure Solution Lab 11 – Multi-Member Groups PS-M4110

  27. Questions?

More Related