270 likes | 419 Views
Da F ne upgrade (as seen by a KLOE member). G. Venanzoni – INFN/Frascati. International Workshop on e+ e- collision from Phi to Psi Novosibirsk, 27 Feb – 2 Mar 2006. Outline:. Status of DA F NE Upgrade of DA F NE: Short term project Long term project Physics program at DAFNE-2
E N D
DaFne upgrade(as seen by a KLOE member) G. Venanzoni – INFN/Frascati International Workshop on e+ e- collision from Phi to Psi Novosibirsk, 27 Feb – 2 Mar 2006
Outline: • Status of DAFNE • Upgrade of DAFNE: • Short term project • Long term project • Physics program at DAFNE-2 • Upgrade of the detector • Conclusion DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
DAFNE e+e- machine at Frascati (Rome) KLOE detector e+ e- FINUDA detector • e+e f s ~ mf = 1019.4 MeV • beams cross at an angle of 12.5 mrad • LAB momentum pf~ 13 MeV/c DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
DANE performance up to Dec 2005 Peak Luminosity 1.4 x 1032 cm2s1 2 Off peak run Integrated Luminosity Day performance: 7-8 pb-1 Bestmonth L dt ~ 200 pb1 Total KLOE L dt ~ 2400 pb1 (2001,02,04,05) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
DAFNE 24h Performance (Dec. 05) 1.2e-32 2 A e- e+ 1 A 8 pb-1 DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Machine energy stability s monitored to within 70 keV Some variations in 2004 Stable (1019.3-1019.6) in 2005 2004 2005 DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
DaFne Upgrade – short term (3 years) • Starting from 1.51032, 2fb-1/year: • Reduction of e- ring beam impedance (by a factor 2) : • Removal and shielding of the broken Ion-Cleaning-Electrodes • Higher positron current (up to 2 A), so far limited to 1.3 A: • New injection kickers • Ti-Coating against electron cloud • Feedback upgrades • Wigglers modifications to increase Lifetime (by a factor 2): • New interaction region • Transfer lines upgrade (continuous injection) • To be discussed: • Crab cavities, waist modulation (RF quads) • Final luminosity 3 times higher? DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
DAFNE-2: Long term upgrade (2010)also for high energy program (up to 2.4 GeV) • Change of machine layout, insertion of: - Superconducting cavities • - Superconducting wigglers • - Ramping Dipoles • - New vacuum chamber DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
TDR in preparation: necessary to submit the project IR DAFNE 2 layout Wigglers rf DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Physics at DAFNE-2 See presentation of M. Testa • Kaon Physics (including test of QM with interferometry) • (Multi)hadronic cross section up to 2.4 GeV • Spectroscopy (vector mesons) • gg physics • Time-like form factors (baryons and mesons) • Radiative f decays • Kaonic Nuclei See presentation of S. Eidelman DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
TOTAL CROSS SECTION R Energy Scan Radiative return DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Impact of DAFNE-2 on inclusive measurement 20 pb-1 Lint (nb-1) 1) Most recent inclusive measurements: MEA and B antiB, with total integrated luminosity of 200 nb-1 (one hour of data taking at 1032 cm-2 sec-1).10% stat.+ 15% syst. errors 2) With 20 pb-1 per energy point, stat. errors on d(Dahad)/Dahad O(5%); systematic error will be reduced as well 4) a precise comparison exclusive vs. inclusive can be carried out • MEA, 14 points, Lett. Nuovo Cim.30 (1981) 65 • B antiB, 19 points, Phys.Lett.B91 (1980) 155 s (GeV) s (GeV) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Impact of DAFNE-2 on exclusive channels in the range [1-2] GeV with a scan (Statistical only) 3p BaBar, with the published Lint per point (90 fb-1) BaBar, with 10 (the present Lint ) DAFNE-2, with 20 pb-1 per point 2K2p • DAFNE-2 is statistically better than O(1ab-1) B-factories • Improvement on systematics come as well 4p DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Impact of DAFNE-2 on the range [1-2] GeV (3p) using ISR @ 2.4 GeV (Statistical only) BaBar, with the published Lint per point (90 fb-1) BaBar, with 10 (the present Lint ) DAFNE-2, with 2 fb-1 @ 2.4 GeV comparison among the present BaBar analysis, an (O(1 ab-1)) BaBar update, and Lint = 2 fb-1 at 2.4 GeVper energy point @ DAFNE-2, in the impact on d(Dahad) /Dahad : p- p+ p0: O(9%) |O(3%)|O(8%) statistical dshad / shad (%) • DAFNE-2 is competitive with B-factories with current statistics s (GeV) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
gg Physics at DAFNE-2 gg P [p0 , h , h’] G(Pgg) gg p0p0 , p+p- , hp, hpp G(Sgg) / test of ChPT • h’, f0(980), a0(980) needs √s > Mf • At f peak an e+/- tagger is needed (background). • News: • KLOE run off-peak: “test run” for gg physics • Renewed interest for per gg p0p0 at threshold • DAFNE-2 higher √s Ggg di f0 e a0 DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Search for s [ f0(600) ] ingg p0p0 G(s gg)×G(s pp) sensitive to quark structure (4q vs. 2q) Which √s ? 1 GeV ok (Off f peak) More information from KLOE test run BELLE f0(980) f2(1270) gg p+p- Efficiency cut Only data available gg p0p0 [Crystal Ball @ DORIS 1990] Wgg>0.7 GeV DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
From s(e+e- NN) |G|2 (2) From the angular distribution |GE|/|GM| (3) From the polarization F(q2) =fE - fM Time-like form factors Threshold for Baryons (GeV) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Existing data Proton data - type (1) Ipothesis GE=GM Neutron: only FENICE (500 nb-1, ~75 evts signal) No data available on polarization Proton data: |GE|/|GM| - type (2) DAFNE-2: with a scan of 20 points, 50 pb-1 per point, (one year of data taking) from 40000 × e (at threshold) to 10000 × e (a 2.5 GeV) Total number of events ~ 5 × 105 × e With e = 10% DAFNE-2 is 10 times better Babar (current results) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
h, h’ at DAFNE-2 F-factory = h ed h’ factory BR(f hg) = 1.3 ×10-2 Nh(20 fb-1) ~ 9 × 108 BR(f h’g) = 6.2 ×10-5 Nh’(20 fb-1) ~ 5 × 106 Monochromatic prompt photon: clear signature Mixing h – h’: Uncertainty dominated by systematics; improvement can come by measuring main h’ BR’s h decays: h p0gg (test ChPT; major improvements expected with 20 fb-1) Dalitz decays: h e+e-g, m+m-g, e+e-e+e- Transition FF h p+p-e+e- (Test of CP violation, analogous to KL p+p-e+e- ) Improvements on forbidden/rare decays h’ decays: Dalitz plot of h’hp+p- scalar amplitude h’p+p-p0 first observation / isospin violation DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Scalars at DAFNE-2 • Beside gg process, scalars f0(980), a0(980) • will be copiously produced in the radiative decay of the f • With 20 fb-1the decay f f0g , f0K+K- (KK) (expected BR ~ 10-(6-8))will be well measured (105K+K- and 103KK). direct measure of thegfKK coupling DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Detector Issues (KLOE taken as reference) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
The ingredients of KLOE success E.M: Calorimeter: Drift Chamber: Good momentum resolution Full angular coverage Exceptional timing capabilities Large tracking volume Large lever arm Minimization of materials Excellent e/ separation based on t.o.f. Good 0 reconstruction capabilities Full kinematical reconstruction of events Maximization of efficiency for long-lived particles (K± ,KL) DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
There can be improvements Still, based on our experience, some possible modifications can improve KLOE performance • Use of a lower magnetic field. This can increase acceptance for several of the above mentioned channels and ease pattern recognition • Insertion of a vertex chamber. At present, first tracking layer is at 30 cm (i.e. 50 S) from the I.P. • Try some z coordinate reconstruction in the drift chamber. Pattern recognition would benefit of it. • Increase calorimeter’s readout granularity. Can improve photon counting, as well as particle identification. • A small angle tagger for gg physics DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Conclusion • A high luminosity factory is a perfect tool to study a wide variety of relevant physics topics in several distinct and complementary ways • With KLOE we have learned a lot on how to perform these measurements and have solid ideas on the potentialities of our detector • We have also several ideas on the potential improvements that can be done and intend to study in detail the feasibility and relevance of all of them in the coming months • The high energy program is important. The detector upgrade discussed is fine for that (Only FF measurement requires a further upgrade). Precise measurements (of R for example) need confirmation from different detectors/experiments! DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Time schedule Conceptual Design Report of the accelerator end 2006 international collaboration on the machine design is highly desirable Preliminary Letters of Intent for experiments are in preparation. We need to have an international collaboration. Experiment Letters of Intent Spring 2006 If you are interested to join this adventure, you are welcome! DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
SPARES DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006
Prospectives for h & scalars physics@20fb-1 Large samaple ofh9x108and h’ 4x106 Intersting channels h p0gg BR( 8.0 ± 2.7 ) × 10- with e=4.63% 3000evts study of gg spectrum h, h’ g l+l-,lll(‘)l(‘)(Dalitz & double dalitz decays) with high statistics h p+p-e+e -test of CP violation beyond SM h’ hp+p- sensitive tos(600)expcted 200.000 events With 20 fb-1 f f0g , fK+K- (KK) (expected BR ~ 10-6(-8)) well measured (105K+K- and 103KK), direct measure of the gfKK coupling DaFne upgrade – G. Venanzoni, Novosibirsk, 27 Feb – 2 Mar 2006