1 / 9

- Where are the entry points of the instrument - Physical External links

EUSO-BALLOON DESIGN REVIEW, 18.12.2012, CNES TOULOUSE. EUSO-BALLOON External Interfaces. Sylvie Dagoret-Campagne LAL, Orsay. - Where are the entry points of the instrument - Physical External links - Overview of the External Interfaces - Status - Conclusion.

ferrol
Download Presentation

- Where are the entry points of the instrument - Physical External links

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EUSO-BALLOON DESIGN REVIEW, 18.12.2012, CNES TOULOUSE EUSO-BALLOON External Interfaces Sylvie Dagoret-Campagne LAL, Orsay • - Where are the entry points of the instrument • - Physical External links • - Overview of the External Interfaces • - Status • - Conclusion

  2. Where are the entry points inside the instrument DP PDM IRCAM EC-Front GPSR IR-CAM EC-DYNODE LVPS-DP1 CLKB EXT data MAPMT EC-HV CCB Telemetry EC-ANODE SIREN SPACEWIRE /PCI CNES Telemetry CPU LVPS-DP2 EC-ASIC DST Batteries PDM-B Power 5 V Bat Controller LVPS-PDM HVPS2 PWP monitoring HK HVPS1 LVPS-HK Sensors HVPS control&status Motors EC-Back TLS Power 28 V External Interfaces

  3. ExternalPhysical links RS232/RS422 conv TC TM ON/OFF +/- 12 V CPU HK LVPS HK wifi GPS ON/OFF 3 V Ethernet External Interfaces

  4. Overview of the external interfaces • A- SIREN-LVPS-HK • - Purpose is to initiate a turn ON/OFF initial procedure for the instrument • - Technically : two open drain links (SIREN-TOR) over the ± 12 V and 3.3 V converters of LVPS-HK • B-SIREN-HK • - High level commands implying the instrument life (turn ON/OFF of various components by the action on their supply voltage through HK) • - Standard Telecommand (TC) for the instrument control, • Standard Telemetry monitoring (TM) on the power supplies (Voltage), Temperature of the components, • Technically : RS232/RS422 interface • C-SIREN-CPU • Retrieve information on runs and events like the trigger rate, • Retrieve information from selected events according criteria adapted to the allowed transmission rate, • Issue CPU commands. • Technically Ethernet RJ45 Instrument and Objectives

  5. Overview of the external interfaces • A- SIREN-LVPS-HK • - Purpose is to initiate a turn ON/OFF initial procedure for the instrument • - Technically : two open drain links (SIREN-TOR) over the ±12 V and 3.3 V converters of LVPS-HK • B-SIREN-HK • - High level commands implying the instrument life (turn ON/OFF of various components by the action on their supply voltage through HK) • - Standard Telecommand (TC) for the instrument control, • Standard Telemetry monitoring (TM) on the power supplies (Voltage), Temperature of the components, • Technically : RS232/RS422 interface • C-SIREN-CPU • Retrieve information on runs and events like the trigger rate, • Retrieve information from selected events according criteria adapted to the allowed transmission rate, • Issue CPU commands. • Technically Ethernet RJ45 Instrument and Objectives

  6. Overview of the external interfaces • A- SIREN-LVPS-HK • - Purpose is to initiate a turn ON/OFF initial procedure for the instrument • - Technically : two open drain links (SIREN-TOR) over the ±12 V and 3.3 V converters of LVPS-HK • B-SIREN-HK • - High level commands implying the instrument life (turn ON/OFF of various components by the action on their supply voltage through HK) • - Standard Telecommand (TC) for the instrument control, • Standard Telemetry monitoring (TM) on the power supplies (Voltage), Temperature of the components, • Technically : RS232/RS422 interface • C-SIREN-CPU • Retrieve information on runs and events like the trigger rate, • Retrieve information from selected events according criteria adapted to the allowed transmission rate, • Issue CPU commands. • Technically Ethernet RJ45 External Interfaces

  7. Status of External Interfaces HK Microcontroller CPU External Interfaces

  8. Conclusions • Component links done according state of the art EMC rules • Refer to the Electrical Architecture document and Pierre Prat’s presentation, • All connectors and pin assignment done for each component, • Refer to the Electrical Interface Document and to Michel Dupieux’spresentation • Cables procurement attributed, • Refer to the subsystem manager’s presentations • Functions and purposes defined, • Refer to the software documents for numeric interfaces and Francesco Cafagna’s presentation • No remaining Open point External Interfaces

  9. END ON EXTERNAL INTERFACES RS232/RS422 conv ON/OFF +/- 12 V CPU HK ON/OFF 3 V LVPS HK CCB LVPS PDM LVPS1 CLK GPS Ethernet DP box modules External Interfaces