1 / 54

Cisco NX-OS Data Center Features

Cisco NX-OS Data Center Features. Jack Ross CCIE #16728. Agenda. Brief Hardware Overview Software Versions NX-OS Layer 2 NX-OS Layer 3 FabricPath Virtual Device Contexts (VDC’s) Fiber Channel Over Ethernet ( FCoE ) Overlay Transport Virtualization (OTV) Virtual Port Channels ( vPC’s ).

fifi
Download Presentation

Cisco NX-OS Data Center Features

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cisco NX-OS Data Center Features Jack Ross CCIE #16728

  2. Agenda • Brief Hardware Overview • Software Versions • NX-OS Layer 2 • NX-OS Layer 3 • FabricPath • Virtual Device Contexts (VDC’s) • Fiber Channel Over Ethernet (FCoE) • Overlay Transport Virtualization (OTV) • Virtual Port Channels (vPC’s)

  3. Nexus 7000 Overview Nexus 7000/7700 – Typically DC core or aggregation – High performance, density, & availability – Unified I/O FCoEswitch but not a FC switch – Redundant Power, Line Cards and Supervisors

  4. Nexus 7000 Platform Overview • Currently 7 form factors – 7018, 7010, 7009, 7004, 7718, 7710,7706 • Currently 2 types of line cards – M Series Cards - Layer 3 cards • Feature rich cards – F Series Cards - Layer 2 cards* • Performance oriented cards

  5. Line Card Features • M Series Specific – Layer 3 Routing – FEX – OTV – TrustSec • F Series Specific – FabricPath – vPC+ – FCoE

  6. Nexus 5000 Overview Nexus 5000/5500 – Typically End of Row (EoR) aggregation or Top of Rack (ToR) access – Typically Layer 2 but can do limited Layer 3 with add on daughter card in the 5500 Series Unified I/O – Both FCoE and native FC switching – Redundant power but not supervisors

  7. Nexus 5000 Platform Overview • Currently 2 Generations – 1st Gen - Nexus 5000 – 5010 & 5020 – 2nd Gen - Nexus 5500 – 5548 & 5596 • Mainly layer 2 switching – 5500 can support L3 add-in card • Supports Unified I/O – Both FCoE Forwarder (FCF) and native FC switching • 5500 supports Unified Ports (UP models) – Ports can run as Ethernet or native Fibre Channel – Ethernet ports allocated at port 1 and counts up – Fibre Channel ports allocated at last port and counts down – Requires a reboot to re-allocate port’s role (like UCS FI)

  8. Nexus 2000 • Fabric Extender (FEX) • Acts as a remote line card of 7K or 5K chassis • All management performed on Parent Switch – No console or VTY ports on FEX – NX-OS automatically downloaded from Parent • No local switching – Essentially a VN-Tag/802.1BR switch, not an Ethernet switch – Traffic between local ports on FEX must flow “north” via uplink to Parent and then “south” back down – Can impact design decision of platform placement

  9. Software Versions for CCIE Lab • NX-OS v6.0(2) on Nexus 7000 Switches (6.2(6) latest) • NX-OS v5.1(3) on Nexus 5000 Switches • NX-OS v4.2(1) on Nexus 1000v • NX-OS v5.2(2) on MDS 9222i Switches • UCS Software release 2.0(1x) for UCS-6248 Fabric Interconnect

  10. Nexus NX-OS Basics Nexus at its core is a Layer 2/3 Switch Similar in many aspects to Catalyst IOS – VLANs, Trunking, VTP, Rapid PVST, MST, EtherChannel, PVLANs, UDLD, FHRPs, IGPs, BGP, etc. Key new features beyond Catalyst IOS – FEX, vPC, Fabric Path, OTV, FC Switching, FCoE, etc

  11. NX-OS Port Channels/EtherChannels • Unlike IOS, NX-OS does not support PAgP – Channels must be statically on or LACP negotiated no “switchport mode desireable” – LACP must be enabled with feature lacp • One of the “killer apps” of NX-OS is Virtual Port Channels (vPC) – Multi-Chassis EtherChannel (MEC/MCEC) – Analogous to 3750 Cross StackWise Channel & 6500 Virtual Switching System (VSS)

  12. NX-OS Spanning Tree • Unlike IOS, NX-OS does not support legacy CST/PVST+ – Default STP mode is Rapid-PVST+ – i.e. per-VLAN, but uses 802.1w Rapid STP – Also supports 802.1s Multiple Spanning Tree (MST) • NX-OS defines three STP port types – spanning-tree port-type [normal | edge | network]

  13. NX-OS Switchport Types spanning-tree port-type normal – Normal ports act like Catalyst IOS ports – Default STP port type, run Rapid Per VLAN STP spanning-tree port-type edge – Edge ports are STP PortFast ports spanning-tree port-type network – Network ports run STP Bridge Assurance

  14. Bridge Assurance • All STP Network Ports send BPDUs regardless of STP port state – Legacy 802.1d only sends BPDUs from Root Bridge downstream – Primary goal is to protect against unidirectional links – BPDU becomes a bidirectional keepalive – Replaces LoopGuard functionality • Secondary result is same functional effect as VTP Pruning – VLANs stop forwarding on trunk links that you do not receive BPDUs for that VLAN in • Enabled on interfaces with spanning-tree port type network

  15. Bridge Assurance Diagram switchport trunk allowed vlan

  16. NX-OS Layer 3 Like Catalyst IOS, NX-OS supports… – Native layer 3 routed interfaces I.e. no switchport Switched Virtual Interfaces (SVIs) • I.e. VLAN interfaces • Must be enabled with feature interface-vlan

  17. NX-OS Routing Protocols • Like IOS, NX-OS supports routing with… – Static routing – RIPv2 & RIPng – EIGRP & EIGRPv6 – OSPF & OSPFv3 – IS-IS – BGP – Policy Routing – No network command in IGP’s, activated on link • Not all protocols use the same license

  18. NX-OS VRF • Like IOS, NX-OS Virtual Routing & Forwarding Instances are used to create separate logical routing tables – Layer 3 interfaces in different VRFs cannot exchange traffic by default • NX-OS VRFs behave slightly different than IOS, as… – All layer 3 interfaces are automatically in VRF table “default” – MGMT0 is automatically in vrf “management” – VRFs are defined as vrf context – Static routes are defined under the vrf context – Dynamic routing is VRF aware, but configured under the same process – Exec mode routing-context vrfcan change the default VRF for verifications

  19. NX-OS Redistribution • Unlike IOS, route-maps are required to perform redistribution on NX-OS – Same route-map match/set logic as IOS • Redistribution does not include directly connected interfaces – Requires redistribute direct route-map…

  20. Fabric Path • Pre Standard version of TRILL • Essentially Layer 2 Ethernet Routing • Uses ISIS to route Layer 2 Frames instead of using STP • Can build arbitrary Topologies – Full Mesh, Partial Mesh, Triangle, Square, etc • Adds a TTL in Layer 2 • When using with vPC referred to as vPC+

  21. Fabric Path Configuration • Very few commands necessary • Enable FabricPath – install feature-set fabricpath – feature-set fabricpath • Configure FabricPath VLANs – mode fabricpath under VLAN • Configure FabricPath Core Ports – switchport mode fabricpath

  22. Virtual Device Contexts (VDC) VDCs used to virtualize physical hardware of Nexus 7000 – Loosely analogous to SDRs in IOS XR or Contexts in ASA • VDCs also virtualize control plane protocols of Nexus 7000 – Not analogous to VLANs or VRFs in IOS – Separate control plane per VDC • VLAN 40 in VDC 1 is not VLAN 40 in VDC 2 • OSPF PID 20 in VDC 1 is not OSPF PID 20 in VDC 2

  23. Why VDC’s? Multiple logical roles per physical chassis – E.g. Core & Aggregation/Distribution on same box Multi-Tenancy – E.g. VDCs as a managed service to customers Test Lab Environment for later Production Use Required for certain features – FCoE/Storage

  24. VDC Caveats Some features can’t co-exist in same VDC – OTV and VLAN interfaces (SVIs) – F2 cards and M1/F1 – FCoE requires its own “Storage” VDC Hardware and Software version dependent, check the release notes

  25. VDC Maximums • 4 VDCs per chassis with SUP 1 • 4+1 VDCs per chassis with SUP 2 • 8+1 VDCs per chassis with SUP 2E* • No internal cross VDC communication – E.g. no route leaking like in VRFs – Physical cable can be used to connect VDCs

  26. The Default VDC • Default VDC “1” always exists and cannot be removed • Used to create and manage other VDCs – Controls VDC port allocations • All ports allocated to default VDC at initialization – Controls VDC resource allocations • Number of VLANs, VRFs, Routing table memory, etc. • Can be used for normal data plane operations – “Recommended” for management of chassis only

  27. Default VDC Tasks Some tasks can only be performed in the default VDC – VDC creation/deletion/suspend – Resource allocation – interfaces, memory, MAC’s – NX-OS Upgrade across all VDCs – ISSU or EPLD Upgrade – Ethanalyzer captures – control plane traffic – Feature-set installation for Nexus 2000, FabricPath, FCoE – Control Plane Policing (CoPP) – Port Channel load balancing hash – Hardware IDS check control – ACL Capture feature enable – System-Wide QoS

  28. Converged Ethernet or FCoE • Lots of terms that essentially mean the same thing – Unified Fabric – Unified Wire – Converged Ethernet – Converged Enhanced Ethernet – Data Center Ethernet – Data Center Bridging • What they all really mean… – You are running the physical framing for both Ethernet and Fibre Channel over the same physical links

  29. FCoE Terms • FCoE Initialization Protocol (FIP) • FCoE Forwarder (FCF) • ENode – End Device • Virtual Fibre Channel (VFC) Interface

  30. FC, FCoE, FCIP and iSCSI

  31. How FCoE Works • FCoEreplaces layer 1 & 2 transport for FC • All upper layer FC services remain – Domain IDs, FSPF, FCNS, FLOGI, Zoning. • New FCoE Initialization Protocol (FIP) to negotiate between Fabric and Node – Fabric is the FCF – Node is the ENode

  32. FCoE Control and Data Planes • FIP is the control plane of FCoE • FCoE is the actual data plane • FIP – New EtherType 0x8914 – Used to discover FCFs and perform FLOGI _ UCS C when FCoE turned on uses LLDP to begin negotiation • FCoE – New Ethertype 0x8906 – Min length of 2240 bytes, FC has larger payload • Implies Jumbo Frames are required

  33. OTV Basics • Overlay Transport Virtualization (OTV) – Layer 2 VPN over IPv4 • Specifically OTV is… – IPv4/IPv6 over Ethernet… over MPLS… over GRE… over IPv4…

  34. OTV vs. other Layer 2 DCI’s Layer 2 DCI is needed for Virtual Machine Workload Mobility i.e. VMware VMotion • Many possible options for L2 DCI – Dark Fiber (CWDM/DWDM) – Layer 2 Transport Protocol (L2TPv3) – Any Transport over MPLS (AToM) – Virtual Private LAN Services (VPLS) – Bridging over GRE – Spanning Tree Bridge Group • These options can be used for DCI, but OTV was made for DCI – Optimizes ARP flooding over DCI – Demarc of the STP domain – Can overlay multiple VLANs without complicated design – Allows multiple edge routers without complicated design

  35. OTV Terms • OTV Edge Device – Edge router(s) running OTV • Authoritative Edge Device (AED) – Active edge router for a particular VLAN – Allows multiple redundant edge routers while preventing loops • Extend VLANs – VLAN being bridged over OTV • Site VLAN – Internal VLAN used to elect AED

  36. OTV Terms Continued • Site Identifier – Unique ID per DC site, shared between AEDs • Internal Interface – Layer 2 interface where traffic to be encapsulated is received • Overlay Interface – The logical OTV tunnel interface that performs the OTV encapsulation • OTV Join Interface – The Layer 3 physical link or port-channel that you use to route upstream towards the DCI

  37. OTV Overview

  38. OTV Control Plane • Uses IS-IS to advertises MAC addresses between AEDs – Is it’s own transport and extensible • ISIS Encapsulated as Control Group Multicast – IS-IS over Ethernet over MPLS over GRE over IPv4 Multicast – Implies that DCI must support ASM Multicast

  39. OTV Data Plane • Uses both Unicast and Multicast Transport • Multicast Control Group – Multicast or Broadcast Control Plane Protocols – E.g. ARP, OSPF, EIGRP, etc. • Unicast Data – Normal Unicast is encapsulated as Unicast between AEDs • Multicast Data Group – Multicast Data flows are encapsulated as SSM Multicast – Implies AEDs use IGMPv3 for (S,G) Joins

  40. OTV Adjacency Server • Normally OTV requires that the DCI runs multicast – Needed to find and form IS-IS adjacencies and to tunnel multicast data traffic • OTV Adjacency Server removes multicast requirement – One (or more) AEDs are configured as the adjacency server – All other AEDs register with the adjacency server – Now all endpoints are known • All control and data plane traffic is now unicast encapsulated – Will result in “Head End Replication” when more than 2 DC’s connected over the DCI

  41. OTV DCI Optimizations • Other DCI options bridge all traffic over DCI – STP, ARP, L2 Flooding, broadcast storms, etc. • OTV reduces unnecessary flooding by… – Proxy ARP/ICMPv6 Cache on AED – Terminating the STP domain on AED

  42. vPC Port Channels – Port Channels, EtherChannels, & NIC Teaming/Bonding terms used interchangeably – Regardless of vendor, 802.3ad (LACP) refers to Port Channeling • Used to aggregate bandwidth of multiple links between devices – E.g. 4 x physical 1GigE links form a 4GigE logical Port Channel • Appears as one logical link from STP’s perspective – Avoids active/standby and allows active/active

  43. vPC Port Channels • Data flows are load balanced between member links – Single flow cannot exceed BW of any physical member link • E.g. increases lanes on the highway but not the speed limit • Does not perform LFI like PPP Multilink • Flows are load balanced based on L2, L3, & L4 header information – SRC/DST VLAN, MAC, IP, & TCP/UDP Port • Default is SRC/DST L3 for IPv4/IPv6 and SRC/DST MAC for non IP – Can result in over/under subscribed links

  44. Port Channels • Port Channeling was original between only 2 devices – 1 downstream device & 1 upstream device • E.g. end host to Catalyst 3550 via 2 x FE links – Increases BW but still has single point of failure • Multi Chassis EtherChannel (MCEC/MEC) is between 3 devices – 1 downstream device & 2 upstream devices • E.g. end host to 2 x Catalyst 3750s via 2 x GigE links – Increases BW and resiliency – Logically appears the same as a 2 device Port Channel

  45. Multi Chassis Ethernet Channels • 3750 StackWise & 6500 VSS single control plane – StackWise via Stacking Cable to connect BP – VSS via Virtual Switch Link (VSL) • vPC uses two separate control planes – Configurations managed independently – Separate control plane protocol instances • STP, FHRPs, IGPs, BGP, etc. – Synchronization via a Peer Link • Similar logic to VSS’s VSL

  46. vPC Peer Switches • vPC made up of 2 physical switches – The vPC Peers • vPC Peers each have… – vPC Peer Link – vPC Peer Keepalive Link – vPC Member Ports

  47. vPC Overview

  48. vPC Peer Link • Layer 2 trunk link used to sync control plane between vPC peers – CAM table, ARP cache, IGMP Snooping DB, etc. – Uses Cisco Fabric Service over Ethernet (CFSoE) protocol – Used to elect a vPC Primary and vPC Secondary Role • Normally not used for the data plane – Peer Link generally much lower BW than aggregate of vPCMember Ports – If Peer Link used in the data plane, it is the bottleneck

  49. vPC Peer Keepalive • Layer 3 link used as heartbeat in the control plane – Used to prevent active/active or “Split Brain” vPC Roles – Not used in the vPC data plane – Uses unicast UDP port 3200 • Peer Keepalive Link can be… – Mgmt0 port • Back to back or over routed infrastructure • Ideally in an isolated VRF

  50. vPC Member Ports • Data plane port channel towards downstream neighbor • Each vPC Peer has at least one member port per vPC – Can be more, up to hardware platform limits • From perspective of downstream neighbor, upstream vPC Peers are one switch – Physical result is a triangle – Logical result is a point-to-point Port Channel with no STP blocking ports

More Related