1 / 34

Quality Control for PH of Tea

Quality Control for PH of Tea. Final Presentation. YU Jiayi , CUI Liwen , CHEN Rui , GUO Dingcheng , CAO Qing. Project Overview. Suggestions. PH value. DOE. Gage R&R. Off-line Experiments. Project Overview. Define (1/3). Study Problem

finian
Download Presentation

Quality Control for PH of Tea

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Quality Control for PH of Tea Final Presentation YU Jiayi, CUI Liwen, CHEN Rui, GUO Dingcheng, CAO Qing

  2. Project Overview Suggestions PHvalue DOE Gage R&R Off-line Experiments

  3. Project Overview

  4. Define (1/3) • StudyProblem • Asthe PH value of tea beverage is an important quality index, wewouldliketostudythefactorsthatwouldaffectthePHvaluethroughoff-line experiments. • WeexpecttoobtaintherecommendedvaluesoftherelatedinfluencefactorstoobtaintherecommendedPHvalue,thusguidingtherealproductionoftea beverage.

  5. Define (2/3) • Response (y) • PH value of tea beverage • Green Tea: PH value of 6.2 recommended • Factors (x) • Temperature • Time • Percentage of Tea • Container (stainless steel, glass, ceramic, etc.)

  6. Define(3/3) • Methodology: Design of Experiment • Off-line experiments • Gage R&R study • GLM • Identify significant factors • Specify relationships between x and y

  7. Project Overview

  8. Measurement Instruments Temperature-control Pot Measuring Cup Electronic PH-meter Electronic Scale

  9. Gage R&R (1/6) • Experiment setting • pH meter • 3 operators • 3 cups of tea • 3 replicates • Parameters • 3g tea • 200 mL water • 8 min

  10. Gage R&R (2/6) • Experiment without SOP • Effect of operatoris significant • Contributions of total Gage R&R: nearly 100% • Repeatability: 62.57% • Reproducibility: 37.43%

  11. Gage R&R (3/6) • Experiment without SOP

  12. Gage R&R (4/6) • Experiment with SOP • Effect of partand interactionare significant • Contributions of total Gage R&R: 35.21% • Repeatability: 14.72% • Reproducibility: 20.49%

  13. Gage R&R (5/6) • Experiment with SOP

  14. Gage R&R (6/6) • The gage has acceptable repeatability and reproducibility • Different operations of operators have large influence in R&R • A proper SOP is required to improve the performance of operators

  15. Project Overview

  16. Design of Experiment (1/2) • fractional factorial design • Response variable: pH value (using pH meter) • Tea: 憩园甘露 • Initial model:

  17. Design of Experiment (2/2) • Sequence of experiment • Three cups of tea are tested in the same period. • The cups are made of different materials. • The total time of each cup is different. • Measure their PH at their own time point. • Control of factors • Temperature: air-conditioner, thermos • Volume of water: measuring glass • Weight of tea: electronic balance

  18. Design of Experiment 0 min 2 min 4 min 不锈钢 陶瓷 玻璃 8 min 7 min 6 min 8-0=8 min 7-2=5 min 6-4=2 min

  19. Experiment process (1/4) • Experiment notes • Cleaning acidometer & container everytime after reading PH value to get accurate data • Put acidometer into tea at least 1 min before reading to get stable PH value • To save time, we compress 3 experiments into one 8 min cycle, with same water temperature

  20. Experiment process (2/4) • Preparation • Make sure the 3 experiments’ parameter combination (3g tea-leaf, same temperature) • 2min, A mL water, B1 container • 5min, A mL water, B2 container • 8min, A mL water, B3 container • Measuring required water & three 3g tea-leaf • Put tea-leaf into 3 container

  21. Experiment process (3/4) • Experiment cycle Pour A mL water into B3 container Pour A mL water into B2 container • Read PH value • Wash acidometer • Put acidometer • into B2 container • Wash B3 container • Pour A mL • water into B1 • container • Wash acidometer • Read PH value • Wash acidometer • Wash B1 container 0 min 1 min 2 min 3 min 4 min 5 min 6 min 7 min 8 min • Read PH value • Wash acidometer • Put acidometer into B1 container • Wash B2 container Measuring A mL water Measuring A mL water Put acidometer into B1 container 8 min 5 min 2 min

  22. Experiment process (4/4) Measure 3gtea Experiment Snapshots All experiment instruments Read PH value 3 cups per cycle

  23. Design of Experiment (1/9) • Resultof the initial model • All main effects are significant • Three interactions are not significant

  24. Design of Experiment (2/9) • Residual plot

  25. Design of Experiment (3/9) • Mean of main effect

  26. Design of Experiment (4/9) • Interaction

  27. Design of Experiment (5/9) • Result of model without interaction

  28. Design of Experiment (6/9) • Residual plot

  29. Design of Experiment (7/9) • Mean of main effect

  30. Design of Experiment (8/9) • Residual vs. sequence

  31. Design of Experiment (9/9) • Recommended parameter • Time: 2min • Volume of water: 200ml • Material of cup: Ceramic • Temperature: 98C • Estimated pH: 6.231 • Limitation: no consideration on the effect of • Reusing tea • Type of tea

  32. Project Overview

  33. Improve & Control • ImprovementscanbemadetotheproductionlinetoobtainarecommendedPHvalue • Temperature: 98 ℃recommended • Time:2minutes • Tea/waterratio:3gtea/200mlwaterrecommended • Container:changetheoriginalstainlesssteelcontainertotheporcelaincontainer

  34. Thanks 2014/06/13