1 / 12

More Results From Simulation

JC and Marina 01/15/01. More Results From Simulation. Equivalent track angle of Lorentz effect Comparison with ATLAS magnet results Effective temperature in diffusion constant Angular fit of  distribution. Lorentz Angle.

garymaxwell
Download Presentation

More Results From Simulation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JC and Marina 01/15/01 More Results From Simulation • Equivalent track angle of Lorentz effect • Comparison with ATLAS magnet results • Effective temperature in diffusion constant • Angular fit of  distribution

  2. Lorentz Angle Lorentz angle is not a constant along z, shown are overall effects Larger bias voltage  Larger E field  Smaller mobility  Smaller Lorentz angle Syracuse University

  3. Lorentz Angle Comparison Magnetic field: 1.4 Tesla Udepletion is calculated with effective thickness of the sensor Syracuse University

  4. Diffusion Constant Einstein equation: D = k T m / q Reduce Teff from 390K to 300K  Reduce fraction of doublet by 1.4% Syracuse University

  5. Angular Fit With  Distribution FPIX0-Pstop Normal Incidence Data • MC: 0.5 interval, interpolation between points • Normal incident data:  = (1.77  0.09) Syracuse University

  6. 15° Data 20° Data 10° Data 5° Data   Angular Fit With  Distribution FPIX0-Pstop Syracuse University

  7. Detector Inclination Angle • In MINUIT fit, the beam is assumed to be normal incident on the first SSD, the overall rotation of the detector can not be fitted. • The error from the fit is about 0.1°, which should be smaller than error from MC model. • For large angle, the  fit is not very sensitive to angle. • We can consider that the spectrometer is at 1.5° to the beam direction. Syracuse University

  8. Sensitivity of  Fit FPIX0 Pstop at 20 The shape of  distribution at large angle is not as sensitive to track angle as at small angle Syracuse University

  9. Sensitivity of  Fit Angular Sensitivity of  Distribution  Syracuse University

  10. Summary • The Lorentz angle generated agrees with ATLAS results • The effect of effective temperature on diffusion is small but may need to be considered • The fit of  distribution shows that the spectrometer is at 1.5 degree with respect to beam direction Syracuse University

  11. Effect of Signal Coupling • A simple linear coupling between neighbor rows • Smearing effect of linear coupling can be taken away with  correction • Small coupling (5-10%) improves the resolution Syracuse University

  12. Effect of Signal Coupling A simple linear coupling between neighbor rows Syracuse University

More Related