Condensate Trap Heater KGAHT0201KIT

Condensate Trap Heater KGAHT0201KIT. 2013 Fall Zone Meeting Gary Georgette/Jerry Shipman. KGAHT0201CFP. Kit Contents: Condensate trap with heat pad installed Includes: Low voltage harness External thermostat 115 VAC to 24 VAC Step-down transformer Trap grommet

gaston
Download Presentation

Condensate Trap Heater KGAHT0201KIT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Condensate Trap HeaterKGAHT0201KIT 2013 Fall Zone Meeting Gary Georgette/Jerry Shipman UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  2. KGAHT0201CFP • Kit Contents: • Condensate trap with heat pad installed • Includes: • Low voltage harness • External thermostat • 115 VAC to 24 VAC Step-down transformer • Trap grommet • Horizontal direct vent installations • 7/8-in. casing knockout grommet UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  3. Kit Contents-Trap Heater Heat pad is factory-applied and wraps around the entire trap assembly Low voltage harness & transformer leads External thermostat UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  4. Kit Contents-Transformer 115 VAC, Neutral & Ground Leads UL Label Low Voltage Screw Terminals Mounting Screw UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  5. Kit Contents-Grommets 7/8-in. Casing Knockout Grommets Trap Grommet UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  6. Basic Wiring Diagram UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  7. Basic Installation • Remove factory trap from furnace • Install trap from kit on furnace • Remove (2) 7/8-in. knockouts on same side of furnace • Install transformer from kit on field-supplied J-box • Mount J-box to knockout on furnace casing • Install 7/8-in. grommet through knockout for J-box/furnace casing UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  8. Basic Installation • Route external 115 VAC power leads and furnace power leads to J-box • Use external disconnect when required by code • Connect external, furnace and transformer leads together • Install 7/8-in. grommet in other 7/8-in. knockout in casing • Route trap heater leads under inducer assembly and through that grommet in casing • Verify trap heater leads are not touching hot surfaces • Connect low voltage leads to screw terminals on transformer UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  9. Trap Heater Installed UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  10. External Connections Low Voltage Leads & Casing Grommet Secure Excess Wire & Connect to Transformer Furnace Line Voltage Power Leads & Casing Grommet Complete Line Voltage Connections In J Box UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

  11. Conclusion • It’s quick • It’s easy • Instructions on HVACpartners • AG-KGAHT-01 • Questions? UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution