Concept V2.5. Lesson 11 Objectives: After completing this lesson, the learner will be able to: Define the configuration rules associated with the Quantum Controller. Perform the configuration using Concept software. Create an I/O map using the appropriate configuration software.
E N D
Concept V2.5 • Lesson 11 Objectives: • After completing this lesson, the learner will be able to: • Define the configuration rules associated with the Quantum Controller. • Perform the configuration using Concept software. • Create an I/O map using the appropriate configuration software. • Establish special drop characteristics and I/O module setup • Connect to a Quantum controller. • Download a configuration and I/O map to a Quantum controller.
HW State-RAM DDI ... 1:1 - 1:32 1:1 1x DDO ... 0:1 - 0:32 0x 0:1 AVI ... 3:1 - 3:8 3x 3:1 AVO ... 4:1 - 4:4 4x 4:1 I/O Map Ranges Concept V2.5 • I/O Mapping to State Ram FieldDevices UserLogic
Concept V2.5 • I/O Map Overview Screen
Concept V2.5 • Select the required Module
Concept V2.5 • Module Addressing
Concept V2.5 • Module Parameters
Concept V2.5 • Module Parameters (Analog Input Module) • Select required ranges
Concept V2.5 • Module Parameters Help Screen
Concept V2.5 • Module Parameters (Analog Output Module) • Select required output behavior on Timeout
Concept V2.5 • Module Parameters (Discrete Output Module) • Enter required output behavior on Timeout
Concept V2.5 • Connecting to a Quantum PLC
Concept V2.5 • Download and Start a Program
Concept V2.5 • PLC Simulation • Two PLC simulators • Used for online testing of the IEC user program (FBD, SFC, LD, IL, and ST) without any hardware. • SIM (16 Bit) • Simulates a Quantum PLC connected via Modbus Plus. • This simulator is available under Windows 3.1, Windows for Workgroups 3.11, Windows 95 and Windows NT. • Concept PLCSIM32 (32 Bit) • Simulates a PLC connected via TCP/IP, includes simulation of signal states in I/O modules. • Up to 5 programming units can be connected to the simulated Quantum at the same time (via a TCP/IP Ethernet connection). • This simulator is only available under Windows 95/98 and Windows NT.
Concept V2.5 • The 16 Bit Simulator File Location
Concept V2.5 • The 32 Bit Simulator File Location
Concept V2.5 • The 16 Bit Simulator
Simulators • Starting the 32 Bit Simulator
Concept V2.5 • 32 Bit Simulator Initial Quantum Startup • Nothing in Memory
Concept V2.5 • Connect to IEC Simulator(32 Bit) • From IEC Simulator: Select required CPU type • Download configuration and program Select CPU Type
Concept V2.5 • Components of PLCSIM32 CPU Status Select CPU Type Left Mouse Button: Select 16 bit input group Left Mouse Button: Select 16 bit output group Left Mouse Button: Change values of Input, Output, Register addresses Left Mouse Button: Select register address Right Mouse Button: Select value range, format
Concept V2.5 • More Components of PLCSIM32 Left Mouse Button: Change values Right Mouse Button: Change format
Configuration Demonstration and Lab