251 likes | 453 Views
Clarity Chromatography Software. Clarity 3.0 – New features. Calibration Import/Export Chromatogram Event table. User Interface Reports Sequence. More than 10 0 new features in version 3.0. Opening the Clarity Instrument. Select your Project during the logon.
E N D
Clarity Chromatography Software Clarity 3.0 – New features Code: P021/30A
Calibration Import/Export Chromatogram Event table User Interface Reports Sequence More than 100 new features in version 3.0 Code: P021/30A
Opening the Clarity Instrument Select your Project during the logon • Option to select project in Login Dialog • Auto Lock - option to lock Instrument after predefined period Code: P021/30A
Improvements in user interface • User Options - new tab Directories to set paths for PDF reports, exports and imports • Tables - function Fill series (Sequence, Calibration, Gradient) Code: P021/30A
Calibration Code: P021/30A Bracketing, Standard Addition, Normalization Improved Identification Windows Forced Compound Identification New Calibration curves, Linearization of Calibration Graph Axes Calculation by Response of Another Compound Response factor as Amount/Response or Response/Amount Response Correction Factor
Calibration curve check Failure displayed in the Peak Type column in Result Table New Calculation types NORM STDADD Calibration Options Code: P021/30A
Show linearized values in Graph Properties Select appropriate function to linearize the values on X, Y axes Linearization of axes in Calibration Code: P021/30A
Select a new curve: • ln • log10 • exp • pow10 • Hyperbola • Half Sigmoid New Curve Fit Types in Calibration Code: P021/30A
Chromatogram Code: P021/30A User columns – compound name in special values Mathematical operations – invert function to reverse polarity Advanced peak tags File open dialog – option to change overlay mode Result table – peak type indicates more info Support for electronic signatures in PDF reports
Enhanced Peak Type info Ordnr/Ref/ISTD/RISTD/GRP peak type Error value could not be calculated Error (Curve Check) calibration curve does not met preset criteria <LOD and<LOQ value lower then set limits (Forced) identification forced by integration table (by name) another compound calibration data used (CF) correction factor in calibration applied Peak Type in Result Table indicates used calibration options Code: P021/30A
Overlay mode Change to Overlay mode in Open Chromatogram dialog Code: P021/30A
Electronic signatures in PDF reports Code: P021/30A
Force Peak Identification • Name peaks without calibration file • Override identification by calibration Select new Peak Identification Force Peak Identification Select Peak to Force Code: P021/30A
Relative Retention Times Force Peak Identification Setup User Column using the Special Values, Compound option Calculated RRT Code: P021/30A
Customizable order of Report Sections Right click the tab and adjust its position Code: P021/30A
Export of graphs Code: P021/30A Export of graphs from PDA view Export Calibration curve as picture
Export of data in Excel (.xls) format Code: P021/30A
Import Chromatogram Data Store your preferences for future use (user specific) Apply same settings to multiple files opened simultaneously Import of multiple signal chromatogram data aranged in columns Preview the imported data file Preview the imported data file Code: P021/30A
Event table New set of event for running/idle state of Instrument New set of commands in Output Code: P021/30A Events could be performed outside run New input conditions New output actions Resizable dialog and columns width
Valve control Set custom position for Valve at Close Instrument Set custom position for Valve at Close Instrument Input/Output names instead of numbers Code: P021/30A
Sequence Bypass to perform run without injection for startup and shutdown methods • New columns: • Include in SST – perform SST test when injection is finished • Stored Calib. – chromatogram will be opened with stored calibration • Close All – close all currently opened chromatograms in overlay to prepare for next summary report New file name variables %P – Project %s – Sequence %J – Method Code: P021/30A
Bracketing and Standard Addition This calibration will be used with Calibration used as specified by user Calibration and Sequence Usage Clone calibration at each Sequence start Standard Addition Bracketing Copy of the Example Calibration will be created according to Sequence options, Calibration and Sequence Usage Code: P021/30A
Extension and Control Modules • PDA – option Add All Identified Peaks to Spectrum library • FC GP – new option Collect all • Flow rate units options extended to L/min, mL/min, µL/min Code: P021/30A
Control Modules in development Code: P021/30A Agilent 7890 GC Agilent 1200 HPLC DAD (G1315D) Sedere ELSD detector 80LT and 85LT PG Instruments LC-200 HPLC
For more information please visit our website: • What‘s new ( menu: Products – Clarity – Next steps – What is new) • Preliminary Demo version ( menu: Downloads – Preliminary versions) • Preliminary version ( menu: Downloads – Preliminary versions) Code: P021/30A