The services between PP0SDDx and PP1SDDx will have the same layout

Summary of services exiting from PP0SDDx or PP4SDDx, x=0…3 (directed towards the racks for the RB24 side or RB26 side). The services between PP0SDDx and PP1SDDx will have the same layout. October 1 st , 2004 - Preliminary.

gita
Download Presentation

The services between PP0SDDx and PP1SDDx will have the same layout

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Summary of services exiting from PP0SDDx or PP4SDDx, x=0…3(directed towards the racks for the RB24 side or RB26 side) The services between PP0SDDx and PP1SDDx will have the same layout October 1st, 2004 - Preliminary

  2. Services exiting from PP0SDD0 or PP4SDD0(directed towards the racks for the RB24 side or RB26 side) • Each PP0SDD0 and PP4SDD0 serve: Layer 3 / half-ladders 0,1, 2,3 and Layer 4 / half-ladders 0,1,2,3 • LV cables • Power:# 40 AXON X-1091-TSTX-2 (Cu cross-section (91x0.254) = 4.61mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 8.9 mm, unit weight=146.3 g/m, sub-total weight = 5.9 kg/m • Detector bias (HV) • HV# 28 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 0.5 kg/m • MV # 28 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 0.8 kg/m • DCS • # 2 RJ45-RJ45 UTP patch-cord(http://www.cogestra.com/query.asp?c=HW_Cables/Connectors%20Networking&i=CBL-RJ45-44432)unit O.D. = 7.5mm, unit weight = 37.7 g/m, sub-total weight = 0.1 kg/m • Optical fiber ribbons (maximum envelope) • # 8 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • # 6 AISI316L pipes I.D./O.D. = 10/12 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • # 3 AISI316L pipes I.D./O.D. = 12/14 mm ; unit weight = 328.0 g/m , sub-total weight = 1.0 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  3. Services exiting from PP0SDD1 or PP4SDD1(directed towards the racks for the RB24 side or RB26 side) • Each PP0SDD1 and PP4SDD1 serve: Layer 3 / half-ladders 4,5 and Layer 4 / half-ladders 4,5,6,7, 8,9,10,11 • LV cables • Power:# 50 AXON X-1091-TSTX-2 (Cu cross-section (91x0.254) = 4.61mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 8.9 mm, unit weight=146.3 g/m, sub-total weight = 7.3 kg/m • Detector bias (HV) • HV# 76 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 1.2 kg/m • MV # 38 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 1.1 kg/m • DCS • # 3 RJ45-RJ45 UTP patch-cord(http://www.cogestra.com/query.asp?c=HW_Cables/Connectors%20Networking&i=CBL-RJ45-44432)unit O.D. = 7.5mm, unit weight = 37.7 g/m, sub-total weight = 0.2 kg/m • Optical fiber ribbons (maximum envelope) • # 10 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • # 6 AISI316L pipes I.D./O.D. = 10/12 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • # 3 AISI316L pipes I.D./O.D. = 12/14 mm ; unit weight = 328.0 g/m , sub-total weight = 1.0 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  4. Services exiting from PP0SDD2 or PP4SDD2(directed towards the racks for the RB24 side or RB26 side) • Each PP0SDD2 and PP4SDD2 serve: Layer 3 / half-ladders 6,7, 8,9 and Layer 4 / half-ladders 12,13,14,15 • LV cables • Power:# 40 AXON X-1091-TSTX-2 (Cu cross-section (91x0.254) = 4.61mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 8.9 mm, unit weight=146.3 g/m, sub-total weight = 5.9 kg/m • Detector bias (HV) • HV# 56 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 0.9 kg/m • MV # 28 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 0.8 kg/m • DCS • # 2 RJ45-RJ45 UTP patch-cord(http://www.cogestra.com/query.asp?c=HW_Cables/Connectors%20Networking&i=CBL-RJ45-44432)unit O.D. = 7.5mm, unit weight = 37.7 g/m, sub-total weight = 0.1 kg/m • Optical fiber ribbons (maximum envelope) • # 8 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • # 6 AISI316L pipes I.D./O.D. = 10/12 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • # 3 AISI316L pipes I.D./O.D. = 12/14 mm ; unit weight = 328.0 g/m , sub-total weight = 1.0 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  5. Services exiting from PP0SDD3 or PP4SDD3(directed towards the racks for the RB24 side or RB26 side) • Each PP0SDD3 and PP4SDD3 serve: Layer 3 / half-ladders 10,11, 12,13 and Layer 4 / half-ladders 16,17,18,19, 20,21 • LV cables • Power:# 50 AXON X-1091-TSTX-2 (Cu cross-section (91x0.254) = 4.61mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 8.9 mm, unit weight=146.3 g/m, sub-total weight = 7.3 kg/m • Detector bias (HV) • HV# 72 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 1.1 kg/m • MV # 36 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 1.0 kg/m • DCS • # 3 RJ45-RJ45 UTP patch-cord(http://www.cogestra.com/query.asp?c=HW_Cables/Connectors%20Networking&i=CBL-RJ45-44432)unit O.D. = 7.5mm, unit weight = 37.7 g/m, sub-total weight = 0.2 kg/m • Optical fiber ribbons (maximum envelope) • # 10 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • # 8 AISI316L pipes I.D./O.D. = 10/12 mm ; unit weight = 277.5 g/m , sub-total weight = 2.2 kg/m • # 4 AISI316L pipes I.D./O.D. = 12/14 mm ; unit weight = 328.0 g/m , sub-total weight = 1.3 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  6. Services between from PP2SDD0 and PP2SDD0 or between PP3SDD0 and PP4SDD0 • Ladder served: Layer 3 / half-ladders 0,1, 2,3 and Layer 4 / half-ladders 0,1,2,3 • LV cables • Power:# 24 AXON X-1461-TSTX-2 (Cu cross-section (61x0.203) = 1.91mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 5.9 mm, unit weight=69.6 g/m, sub-total weight = 1.67 kg/m • Detector bias (HV) • HV# 28 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 0.5 kg/m • MV # 28 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 0.8 kg/m • DCS • # 56 CERN-04.21.51.704.4unit O.D. = 2.9mm, unit weight = 17.1 g/m, sub-total weight = 1.0 kg/m • Optical fiber ribbons (maximum envelope) • # 8 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • polyurethane pipes # 2 I.D./O.D. = 10/6.5 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m# 5 I.D./O.D. = 12/9.0 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m# 2 I.D./O.D. = 16/11 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  7. Services between from PP2SDD1 and PP2SDD1 or between PP3SDD1 and PP4SDD1 • Ladder served: Layer 3 / half-ladders 4,5 and Layer 4 / half-ladders 4,5,6,7, 8,9,10,11 • LV cables • Power:# 30 AXON X-1461-TSTX-2 (Cu cross-section (61x0.203) = 1.91mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 5.9 mm, unit weight=69.6 g/m, sub-total weight = 2.09 kg/m • Detector bias (HV) • HV# 38 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 0.6 kg/m • MV # 38 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 1.1 kg/m • DCS • # 76 CERN-04.21.51.704.4unit O.D. = 2.9mm, unit weight = 17.1 g/m, sub-total weight = 1.3 kg/m • Optical fiber ribbons (maximum envelope) • # 8 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • polyurethane pipes # 1 I.D./O.D. = 10/6.5 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m# 4 I.D./O.D. = 12/9.0 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m# 4 I.D./O.D. = 16/11 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  8. Services between from PP2SDD2 and PP2SDD2 or between PP3SDD2 and PP4SDD2 • Ladder served: Layer 3 / half-ladders 6,7, 8,9 and Layer 4 / half-ladders 12,13,14,15 • LV cables • Power:# 24 AXON X-1461-TSTX-2 (Cu cross-section (61x0.203) = 1.91mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 5.9 mm, unit weight=69.6 g/m, sub-total weight = 1.67 kg/m • Detector bias (HV) • HV# 28 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 0.5 kg/m • MV # 28 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 0.8 kg/m • DCS • # 56 CERN-04.21.51.704.4unit O.D. = 2.9mm, unit weight = 17.1 g/m, sub-total weight = 1.0 kg/m • Optical fiber ribbons (maximum envelope) • # 8 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • polyurethane pipes #2 I.D./O.D. = 10/6.5 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m#5 I.D./O.D. = 12/9.0 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m#2 I.D./O.D. = 16/11 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  9. Services between from PP2SDD3 and PP2SDD3 or between PP3SDD3 and PP4SDD3 • Ladder served: Layer 3 / half-ladders 10,11, 12,13 and Layer 4 / half-ladders 16,17,18,19, 20,21 • LV cables • Power:# 30 AXON X-1461-TSTX-2 (Cu cross-section (61x0.203) = 1.91mm²)(http://www.axon-cable.com/pdf/halogen_a.pdf)unit O.D.= 5.9 mm, unit weight=69.6 g/m, sub-total weight = 2.09 kg/m • Detector bias (HV) • HV# 36 CERN-04.31.51.750.1unit O.D. = 3.3 mm, unit weight = 15.8 g/m, sub-total weight = 0.6 kg/m • MV # 36 CERN-04.21.51.055.4unit O.D. = 5.0 mm, unit weight = 28.9 g/m, sub-total weight = 1.0 kg/m • DCS • # 72 CERN-04.21.51.704.4unit O.D. = 2.9mm, unit weight = 17.1 g/m, sub-total weight = 1.2 kg/m • Optical fiber ribbons (maximum envelope) • # 8 fiber ribbons (http://www.occfiber.com/products/product_specs.php?CableID=8&Group=Zero%20Halogen)unit O.D. 2.0 mm; unit weight = 8.0 g/m, sub-total weight = 0.1 kg/m • Cooling pipes • polyurethane pipes # 3 I.D./O.D. = 10/6.5 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m# 7 I.D./O.D. = 12/9.0 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m# 2 I.D./O.D. = 16/11 mm ; unit weight = 277.5 g/m , sub-total weight = 1.7 kg/m • Air ducts • Needed mass-flow is 38 m3/h; air has to be filtered and with relative humidity of about 40%

  10. Patch panel labelling PP z ddd y F-number: 0…9, increasing with increasing F SPD, SDD, SSD, FMD, T00, V00, ALG Z-number = 0…4, increasing with decreasing Z

  11. FROM ALICE-INT-2003-038

  12. Possible positions of PATCH PANEL 0 PATCH PANEL 1 (formerly shoe-boxes Z Y PATCH PANEL 2 X

  13. ITS SERVICES RB26 side Patch-Panel 4 (formerly shoe-boxes) ITS-Engineering Meeting 21-09-2004 Y Patch-Panel 3 Z X Pier-Luigi BARBERIS

  14. PP2SDD2 PP2SDD1 PP2SDD0 PP2SDD3 ITS SERVICES RB24 side PATCH-PANEL 2; FRONT VIEW; Z= 1020 ITS-Engineering Meeting 21-09-2004 Pier-Luigi BARBERIS

  15. PP3SDD1 PP3SDD0 PP3SDD3 PP3SDD2 ITS SERVICES RB26 side PATCH-PANEL 3; FRONT VIEW; Z= -1020 ITS-Engineering Meeting 21-09-2004 Pier-Luigi BARBERIS