10 likes | 86 Views
Quality Bulletin. Sanjay Patil. Neeraj Kumar. Horizontal deployment. Running model. New model. Re-FPA. New part approval. Prepared By Approved By. Model. S/No. Product. Claim section. Claim date. Date of imp. Field. WM VS70K11-BPA. WM. Nov-12. Dec-12 ( 16 th ~ ).
E N D
Quality Bulletin Sanjay Patil Neeraj Kumar Horizontal deployment Running model New model Re-FPA New part approval Prepared By Approved By Model S/No. Product Claim section Claim date Date of imp Field WM VS70K11-BPA WM Nov-12 Dec-12 ( 16th ~ ) Quality issue Cause Count measure Analysis -1 Why? During dropping Tub moves at one side & Sharp edge of body corner causes stress on the tub corner. Why? Due to clearance tub moves & Body corner profile outside tilted. Analysis -2 Why? Collar thickness in tub not sufficient to hold the impact Analysis -3 Why? Vibration damping packing position not arresting tub jolting in case of severe bad handling. • Twin tub crack at corner. Body corner profile modified. Bending the corner edge towards inside. Collar thickness in tub increased by 0.5mm. Vibration damping packing position shifted upwards for restrict tub movement Before QA System Improved QA System References Check point for wrinkle & direction of bend after bending has been added to the process audit. PATD / ICTS / Test Std. / IG control no. No check point for Body corner bending operation. ECN No. JIR control no. Others ( Refer OQC/ELT Revision ) " Speed, Durability, Cost"