40 likes | 116 Views
Expert Name for all BLM except Dump. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17+Official name => upto 30. BLM Q I . 06R7 . B1 E 30 _MQMxxx (_S). BLM location: Q for on a quad E for other location 2 for coupled monitors. Observed element.
E N D
Expert Name for all BLM except Dump 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17+Official name => upto 30 BLMQI.06R7.B1E30_MQMxxx(_S) BLM location: Q for on a quad E for other location 2for coupled monitors Observed element Position on the element: 10 at the entrance 20 or 2x at the middle 30 at exit BLM type: I for IC S for SEM Cell and sector position: 01-34 number of cell R or L from IP 1-8 IP Transverse position: E for external I for internal _S added for second coupled monitor counting in beam direction • Beam 1 or beam 2 observed
Observed element names for quads (BLMQI or BLM2I) 1) Observed element names for main and insertion quadrupoles: MQM, MQY, MQ, MQML, MQTL 2)Warm quadrupole: MQWB.4R7 or MQWA.B4R7 3) One IC which observed 2 elements:quad and XRP: 1. BLMQI.04L5.B2E10_MQY_XRP, 2. BLMQI.06R5.B1E10_MQML_XRP 3. BLMQI.06L5.B2E21_MQML_XRP 4)Coupled quads monitors, when the second monitor names are with _S: 1. BLM2I.10L3.B2E30_MQ_MQ_S 2. BLM2I.10R3.B1I30_MQ_MQ_S 3. BLM2I.09L3.B2E30_MQ_MQ_S 4. BLM2I.09R3.B1I30_MQ_MQ_S
Observed element namesfor Dipoles, Collimators, Beam Absorber, Injection and Ejection dump kickers, Injection and Ejection dump septums, BPM, XRP and so on(BLMEI or BLM2I) • Dipoles: BLMEI.08R1.B1E30_MBA BLMEI.06R7.B2I10_MBW.A6R7 BLMEI.01L2.B1I10_MBWMD BLM2I.04R8.B1I10_MBRC_MBRC_S • XRP: BLMEI.04L5.B2E10_XRP • BPM: BLMES.01L1.B1I10_BPMSW.1L1 • Septums: BLMEI.06R8.B2E10_MSIA, BLMEI.06R8.B2E10_MSIB • Kickers: BLMEI.05L2.B1E10_MKI.D5L2.B1 • Collimators: BLMEI.04R7.B1E10_TCSG.B4R7.B1 • Connections: BLMEI.05L6.B2I10_LEJL
Expert Name for BLM at Dump 1)BLMDI.623243.D2I1_MKBH or BLMDI.683780.D1T1_MQY.4R6 BLMPS.683545.B1E1_TCDQA.4R6.B DorP – dump or direct dump 62 or 68 – TD62 or TD68 xxxx (3243, 3780,…) – distance from the beginning of TD, dm D2 or D1 – dump of beam 1 or beam 2 I,E,T,B,L,R,C – internal, external, top, bottom, left, right, centre transverse position _MKBH – observed element • BLMDI.625880.D2L1_377_203 or BLMDI.686850.D1B1_497_254 _377 – distance from IP, m _203 – change of TD diameter, mm 3)BLMDS.689723.D1C1_3.119_DUMP orBLMDI.629822.D2CT_13.200_DUMP _3.119_DUMP – distance from beginning of DUMP (inside of Core), m T – transversal position for IC which installed out of screen