1 / 4

Expert Name for all BLM except Dump

Expert Name for all BLM except Dump. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17+Official name => upto 30. BLM Q I . 06R7 . B1 E 30 _MQMxxx (_S). BLM location: Q for on a quad E for other location 2 for coupled monitors. Observed element.

gwylan
Download Presentation

Expert Name for all BLM except Dump

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Expert Name for all BLM except Dump 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17+Official name => upto 30 BLMQI.06R7.B1E30_MQMxxx(_S) BLM location: Q for on a quad E for other location 2for coupled monitors Observed element Position on the element: 10 at the entrance 20 or 2x at the middle 30 at exit BLM type: I for IC S for SEM Cell and sector position: 01-34 number of cell R or L from IP 1-8 IP Transverse position: E for external I for internal _S added for second coupled monitor counting in beam direction • Beam 1 or beam 2 observed

  2. Observed element names for quads (BLMQI or BLM2I) 1) Observed element names for main and insertion quadrupoles: MQM, MQY, MQ, MQML, MQTL 2)Warm quadrupole: MQWB.4R7 or MQWA.B4R7 3) One IC which observed 2 elements:quad and XRP: 1. BLMQI.04L5.B2E10_MQY_XRP, 2. BLMQI.06R5.B1E10_MQML_XRP 3. BLMQI.06L5.B2E21_MQML_XRP 4)Coupled quads monitors, when the second monitor names are with _S: 1. BLM2I.10L3.B2E30_MQ_MQ_S 2. BLM2I.10R3.B1I30_MQ_MQ_S 3. BLM2I.09L3.B2E30_MQ_MQ_S 4. BLM2I.09R3.B1I30_MQ_MQ_S

  3. Observed element namesfor Dipoles, Collimators, Beam Absorber, Injection and Ejection dump kickers, Injection and Ejection dump septums, BPM, XRP and so on(BLMEI or BLM2I) • Dipoles: BLMEI.08R1.B1E30_MBA BLMEI.06R7.B2I10_MBW.A6R7 BLMEI.01L2.B1I10_MBWMD BLM2I.04R8.B1I10_MBRC_MBRC_S • XRP: BLMEI.04L5.B2E10_XRP • BPM: BLMES.01L1.B1I10_BPMSW.1L1 • Septums: BLMEI.06R8.B2E10_MSIA, BLMEI.06R8.B2E10_MSIB • Kickers: BLMEI.05L2.B1E10_MKI.D5L2.B1 • Collimators: BLMEI.04R7.B1E10_TCSG.B4R7.B1 • Connections: BLMEI.05L6.B2I10_LEJL

  4. Expert Name for BLM at Dump 1)BLMDI.623243.D2I1_MKBH or BLMDI.683780.D1T1_MQY.4R6 BLMPS.683545.B1E1_TCDQA.4R6.B DorP – dump or direct dump 62 or 68 – TD62 or TD68 xxxx (3243, 3780,…) – distance from the beginning of TD, dm D2 or D1 – dump of beam 1 or beam 2 I,E,T,B,L,R,C – internal, external, top, bottom, left, right, centre transverse position _MKBH – observed element • BLMDI.625880.D2L1_377_203 or BLMDI.686850.D1B1_497_254 _377 – distance from IP, m _203 – change of TD diameter, mm 3)BLMDS.689723.D1C1_3.119_DUMP orBLMDI.629822.D2CT_13.200_DUMP _3.119_DUMP – distance from beginning of DUMP (inside of Core), m T – transversal position for IC which installed out of screen

More Related