Rexroth Inline compact I/O technology in your control cabinet SERCOS III Components

Rexroth Inline compact I/O technology in your control cabinet SERCOS III Components. Rexroth Inline SERCOS III Block I/O Digital. SERCOS III Block I/O Digital Inputs Connections for 16 digital sensors Connection of sensors in 2 and 3-wire technology

hada
Download Presentation

Rexroth Inline compact I/O technology in your control cabinet SERCOS III Components

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Rexroth Inline compact I/O technology in your control cabinetSERCOS III Components

  2. Rexroth Inline SERCOS III Block I/O Digital • SERCOS III Block I/O Digital • Inputs • Connections for 16 digital sensors • Connection of sensors in 2 and 3-wire technology • Maximum permissible load current per sensor: 125 mA • Combined Inputs and Outputs • Connections for 16 digital sensors/actuators • Each single channel can only be used as input or as output • Connection of sensors in 2 and 3-wire technology • Maximum permissible load current per sensor: 125 mA • Connection of actuators in 2-wire technology • Nominal current per output: 0.5 A • Short-circuit and overload protected outputs Prototypes: Week 23/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  3. Rexroth Inline SERCOS III Block I/O Digital • SERCOS III Block I/O Digital • Electronic type plate: • Component name • Vendor code • Device Name • Device ID • Revision • Serial Number • Operational hours • Dimensions: • 155.8 mm x 55 mm x 141 mm (width x height x depth) • Ordering Data: • MNR: R911170826 • Type: R-ILB S3 24 DI16 DIO 16 • SOS LP: 600 € Prototypes: Week 23/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  4. Rexroth Inline SERCOS III Block I/O Analog • SERCOS III Block I/O Analog • Inputs • 4 differential analog signal inputs or 4 universal RTD inputs • Connection of sensors in 2. 3. and 4-wire technology • Sensor supply with channel-specific integrated short-circuit and overload protection • Three current measuring ranges: 0 mA to 20 mA. ±20 mA. 4 mA to 20 mA • Four voltage measuring ranges: • 0V to 5V. ±5 V. 0 V to 10 V. ±10V • Various RTD measuring ranges: E.g.. linear R: 0 Ω to 9500 Ω. Pt 100. Pt 1000. Ni 1000 • 16-bit measured value resolution (15 bits + sign bit) • Adjustable filter times (4.5ms; 1.1ms) Prototypes: Week 29/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  5. Rexroth Inline SERCOS III Block I/O Analog • SERCOS III Block I/O Analog • Outputs: • 2 universal analog signal outputs to connect either voltage or current signals • Connection of actuators in 2-wire technology • Three current ranges: 0 mA to 20 mA. ±20 mA. 4 mA to 20 mA • Four voltage ranges: 0 V to 5 V. ±5 V. 0 V to 10 V. ±10 V • Short-circuit-proof outputs Prototypes: Week 29/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  6. Rexroth Inline SERCOS III Block I/O Analog • SERCOS III Block I/O Analog • Electronic type plate: • Component name • Vendor code • Device Name • Device ID • Revision • Serial Number • Operational hours • Dimensions: • 155.8 mm x 55 mm x 141 mm (width x height x depth) • Ordering Data: • MNR: R911170874 • Type: R-ILB S3 24 AI4 AO2 • SOS LP: 950 € Prototypes: Week 29/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  7. Rexroth Inline SERCOS III I/O • SERCOS III Buscoupler • Connects up to 62 standard Inline modules • Automatic baudrate detection on localbus (500kBaud or 2MBaud) • Inputs • Connections for 8 digital sensors • Connection of sensors in 2 and 3-wire technology • Maximum permissible load current per sensor: 125 mA • Outputs • Connections for 4 digital actuators • Connection of actuators in 2- and 3- wire technology • Nominal current per output: 0.5 A • Short-circuit and overload protected outputs Prototypes: Week 47/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  8. Rexroth Inline SERCOS III I/O • SERCOS III Bus coupler • Electronic type plate: • Component name • Vendor code • Device Name • Device ID • Revision • Serial Number • Operational hours • Dimensions: • 80 mm x 70 mm x 121 mm (width x height x depth) • Ordering Data: • MNR: R911170875 • Type: R-IL S3 PB BK DI8 DO4 • SOS LP: approx.: 550 € *) *) not fixed! Prototypes: Week 47/07 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre

  9. Rexroth InlineSERCOS III Cabeling • Free length: • RKB0011 R911316888 • Fix length: • RKB0013 • 0.25 R911317797 • 0.35 R911317800 • 0.55 R911317801 Electric Drives and Controls Stand 05/2006 PRM3 / Norbert Gehre