Legacy Cmd Base

DZ-2500 notes: White and gray wires used only when needed. May not be used on #4 and #5 switches. White and gray wires may be reversed depending on mainline travel through switch. Green and yellow wires used on all mainline switches and switches where derailment is a concern.

hani
Download Presentation

Legacy Cmd Base

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DZ-2500 notes: • White and gray wires used only when needed. May not be used on #4 and #5 switches. • White and gray wires may be reversed depending on mainline travel through switch. • Green and yellow wires used on all mainline switches and switches where derailment is a concern. • Yard and industry switches within easy reach will be manual only. From DZ-2001 Data Driver/Z-1000 From DZ-2001 Data Driver/Z-1000 From DZ-2001 Data Driver/Z-1000 CMD Base Serial Comm DZ-2001 Data Driver DZ-2001 Data Driver MANCO Signal Booster DZ-1008 Relay White wire White wire Legacy Cmd Base Legacy Cmd Base Data MASTER SWITCH To TIU, ASC, etc. Acc #3 SWITCH COMM Comp/ TIU DZ-1008 Relay DZ-1008 Relay Z-1000 14 VAC Blue/White White wire To TIU, ASC, etc. To DZ-2500 Switch Machines LCSPDI 1 ft cable 6-81500 LCS DB9 6-81499 LCS SER2 Module 6-81326 LCSWiFi Module 6-81325 CMD Base Cable 6-14191 Data COMM #2 SWITCH #4 SWITCH Blue/White Z-1000 14 VAC To TIU, ASC, etc. To DZ-2500 Switch Machines To TIU, ASC, etc. Advanced RossReady #4 Double Crossover

  2. CMD Base Serial Comm DZ-2001 Data Driver DZ-2001 Data Driver MANCO Signal Booster Legacy Cmd Base Legacy Cmd Base Data To TIU, ASC, etc. Acc COMM Comp/ TIU Z-1000 14 VAC Blue/White White wire To TPCs, ASCs, etc. To DZ-2500 Switch Machines To other LCS components LCSPDI 1 ft cable 6-81500 LCSPDI cable LCS DB9 6-81499 LCS SER2 Module 6-81326 LCS Sensor Track 6-81326 LCSWiFi Module 6-81325 CMD Base Cable 6-14191 Data COMM Can the MANCO Signal Booster be added here to boost the signal? Blue/White Z-1000 14 VAC To TIU, ASC, etc. To DZ-2500 Switch Machines To TPCs, ASCs, etc.

More Related