1 / 19

Double Beta Decay in SNO +

Double Beta Decay in SNO +. Huaizhang Deng University of Pennsylvania. Collaboration. Brookhaven National Laboratory: R. Hahn, M. Yeh, Y. Williamson, A. Garnov Carleton University: K. Graham Idaho State University: K. Keeter, J. Popp, E. Tatar

harmon
Download Presentation

Double Beta Decay in SNO +

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Double Beta Decay in SNO+ Huaizhang Deng University of Pennsylvania

  2. Collaboration • Brookhaven National Laboratory: R. Hahn, M. Yeh, Y. Williamson, A. Garnov • Carleton University: K. Graham • Idaho State University: K. Keeter, J. Popp, E. Tatar • Laurentian University: D. Hallman, C. Virtue, A. Labelle • LIP Lisbon: S. Andringa, N. Barros, J. Maneira • Queen's University: • M. Boulay, M. Chen, X. Dai, E. Guillian, P. Harvey, C. Kraus, C. Lan, A. McDonald, S. Quirk, P. Skensved, V. Novikov, A. Wright, A. Chia, M. Gobien, J. Lau • SNOLAB: • B. Cleveland, F. Duncan, R. Ford, N. Gagnon, J. Heise, C. Jillings, • I. Lawson • Technical University of Munich: F. v. Feilitzsch, L. Oberauer • University of Alberta: A. Hallin, C. Krauss • University of Pennsylvania: • G. Beier, H. Deng, B. Heintzelman, J. Secrest, T. Shokair • University of Sussex: K. Zuber • University of Texas at Austin: J. Klein

  3. Outline • 150Nd double beta decay • The SNO+ detector • 150Nd loaded scintillator in SNO+ detector • The sensitivity of SNO+ to m • Comparison with other experiments • Conclusions

  4. Double Beta Decay Neutrinos are Majorana particles (Z, N) (Z+2, N-2) Neutrinos have masses Candidates: 48Ca, 76Ge, 82Se, 100Mo, 130Te 136Xe, 150Nd …

  5. Neodymium - 150Nd 28% 150Nd 150Sm + 2e + 2  = 2.9x1019 year 14% 150Nd 150Sm + 2e Q = 3.37 MeV  = ? year 5.6% 0% F. Avignone, Nucl. Phys. B (proc. Suppl) 143 (2005) m=40 meV V.A. Rodin et al., Nucl. Phys. A 766, 107 (2006) m=50 meV

  6. Sudbury Neutrinoless Observatory (SNO+) Sudbury Neutrino Observatory (SNO) • 2092 meters deep underground • 1000 tons of ultrapure D2O • in a 12 meter diameter • acrylic vessel • 1000 tons of ultrapure liquid • scintillator in a 12 meter • diameter acrylic vessel Already Exists ! • 7000 tons of ultrapure H2O • as shield • 9500 PMTs mounted on a • 18 meter diameter frame • electronics, DAQ, • understanding of our detector

  7. SNOLab SNO+

  8. Scintillator in SNO+ • compatible with acrylic, undiluted • high light yield (because it’s undiluted) • Pure, light attenuation length in excess of 20 m at 420 nm • high flash point (130°C) safe • low toxicity safe • low cost (relative to other organic solvents) • smallest scattering of all scintillating solvents investigated • Petresa Canada plant in Quebec makes 120 kton/year, $1600 per ton delivered.

  9. LAB and Fluor • works fine with standard fluors • PPO, butyl-PBD, PPD • 2 g/L concentration works fine LAB-PPO energy transfer efficiency Method 1 (fluorescence emission method): measure the fluorescence excitation and emission of PPO-LAB solution; excitation at 318nm (LAB excitation), integrate emission range from 320 to 550nm (PPO emission)Method 2 (decay time method): excitation at 250nm, emission 360nm, measure the decay times of PPO-LAB solution, compare to the decay time of pure PPO

  10. Light Yield

  11. Attenuation preliminary measurement

  12. Decay Times of Scintillations

  13. Nd Loaded LAB

  14. Other Studies • Acrylic vessel holding structure • Long time stability of Nd loaded LAB with acrylic • Optics of Nd loaded LAB • Upgrade of electronic system • Modification of software packages, Monte Carlo

  15. Energy Spectrum in SNO+

  16. Extract Number of 0 Events

  17. Discovery Potential 3 sigma indication five sigma discovery

  18. Comparison Fabrice Piquemal, Lepton Photon 2007 Calculation with NME from Rodim et al., Suhonen et al., Caurier et al. PMN07

  19. Conclusions • The 150Nd is a good candidate for 0 decay due to large Q and favorable nuclear matrix element • The Nd can be dissolved into SNO+ liquid scintillator with long term stability and good optics. • The large statistics compensate the relatively poor energy resolution in SNO+. The sensitivity to neutrino mass is comparable with other experiments • The SNO detector has been built. We could start SNO+ soon.

More Related