Bulk-scale laboratory experiments of re-entering a sealed heating

Bulk-scale laboratory experiments of re-entering a sealed heating. Mr William Hitchcock Co-Author: Dr Basil Beamish. Presentation Outline. Introduction The UQ 2 metre column Test procedure Test results Discussion of results Conclusions. Background. Re-entering a sealed heating –

havyn
Download Presentation

Bulk-scale laboratory experiments of re-entering a sealed heating

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Bulk-scale laboratory experiments of re-entering a sealed heating Mr William Hitchcock Co-Author: Dr Basil Beamish

  2. Presentation Outline • Introduction • The UQ 2 metre column • Test procedure • Test results • Discussion of results • Conclusions

  3. Background • Re-entering a sealed heating – To do or not to do, that is the question.

  4. Test Apparatus • UQ 2 metre column • Insulated • 8 heaters • Diameter – 0.2m • 8 temp. sensors • Gas collection • Moisture collection • Data Analysis

  5. Test Parameters • High Volatile B Bituminous Coal from the Hunter Valley • Average moisture content = 9.3% • Particle size < 12.7mm • Mass of coal in column = 51kg • Ash content = 4.8% • Start temperature = 40°C • R70 Value = 3.12

  6. Initial test and re-entry times

  7. Hot spot development – Initial test

  8. Re-entry 1: Temperature profiles

  9. Re-entry 2: Temperature profiles

  10. Re-entry 3: Temperature profiles

  11. Conclusions • When a high volatile B bituminous coal is re-entered the coal reaches thermal runaway extremely rapidly. • This is due to the moisture having been removed by the initial heating, thus preconditioning the coal. • For each subsequent re-entry the coal will reach thermal runaway later, due to the combined effect of previous oxidation and moisture remaining in the coal. • Staged re-entries are a preferred option for recovery.