EddiCam: The Eddington Photometric Camera

EddiCam: The Eddington Photometric Camera. Preliminary design. Eddicam. EddiCam design drivers Integration times: 0.5 to 30 s Number of stars to be monitored simultaneously: up to few times 10 5 White light (TBC!!) Duty cycle: > 90%

hetal
Download Presentation

EddiCam: The Eddington Photometric Camera

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EddiCam: The Eddington Photometric Camera Preliminary design . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  2. Eddicam • EddiCam design drivers • Integration times: 0.5 to 30 s • Number of stars to be monitored simultaneously: up to few times 105 • White light (TBC!!) • Duty cycle: > 90% • High photometric accuracy. Noise induced by random perturbations (readout noise, jitter, thermoelastic stability, CCD thermal stability,....): < photon noise. . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  3. Eddicam • Preliminary baseline design • Ø 3° field of view (1.5° x 3° effective FOV in asteroseismology mode) • 20 CCD mosaic • broad band (4000-9000 Å) coverage (white light) . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  4. Eddicam . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  5. Eddicam EddiCam location . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  6. Eddicam • EddiCam components • Focal Plane Assembly: • CCDs array • FEE • Frame store buffer covers • Calibration LEDs • Shutter/cover • Thermal control subsystem . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  7. Eddicam • CCD baseline characteristics • Format: 740 x 2900 pixels • Pixel size: 27 x 27 µm2 • Chip size: 20 x 80 mm2 • Full well capacity: 1.6 Me- • Minimum line readout time: 13 µs • Frame transfer time: 20 ms • Readout noise: 10 - 15 e- at 0.5 MHz • Operational temperature: -80 / -100 C . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  8. Eddicam CCD read out noise as a function of readout frequency . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  9. Eddicam • CCD array preliminary design • 16 + 4 CCDs covering the full FOV • CCDs working in frame transfer mode for asteroseismology (short integrations on bright stars) • CCDs working in full frame mode for planet finding(long integrations on weaker stars) . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  10. Eddicam Frame transfer covers Filters Planet finding CCD layout Asteroseismology layout . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  11. Eddicam • CCD mosaic proposed by Marconi: • 20 CCDs on individual INVAR packages • Each CCD individually mounted on a large INVAR baseplate • All CCDs within ±10 µm from the baseplate: no individual focussing required • Flatness variation < 3 µm from +20 to -100 C • Butting gap around 500 µm . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  12. Eddicam Prototype of CCD array proposed by Marconi . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  13. Eddicam Detail of individual CCD chip package . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  14. Eddicam Detail of XMM-EPIC 7 CCD mosaic . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  15. Eddicam . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  16. Eddicam . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  17. Eddicam . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  18. Eddicam • Wheel with 3 positions: • closed • open • dispersive element • Proably feasible, but expensive...... . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  19. Eddicam • CCD Control Unit • Integration time control • Full frame/transfer frame operation • CCDs windowing • CCDs binning • Selection of readout ports and speeds • Generation of CCDs clocks, bias and power supply • Read Out Electronics • CCD readout • Digitization • Data transmission to Data Processing Unit Simultaneously for 20 CCDs with 40 Mpixels . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  20. Eddicam • Data Processing Electronics • Telecommand management of EddiCam • Scientific onboard data processing (heavy!!) • Generation of TM and communications with OBDH • Power conditioning electronics • Conditioned power supply to CCU, FEE and ROE (very stable and low noise!) • Power supply for shutter, LEDs and covers . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  21. Eddicam . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  22. Eddicam • Preliminar budgets . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  23. Eddicam • The EddiCam Definition Working Group Centro de Astrobiología — Instituto Nacional de Técnica Aeroespacial Centre Spatial de Liège + Universite de Liège Deutsches Zentrum für Luft und Raumfahrt (DLR-Berlin) Institute of Space Sensor Technology and Planetary Exploration Instituto de Astrofísica de Andalucía + Instituto de Astrofísica de Canarias Leicester University + Mullard Space Sciences Laboratory (London) Observatoire de Paris + DAPNIA / CEA (Saclay) Universität Wien . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  24. Eddicam . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse

  25. Eddicam • EddiCam Definition Phase milestones • Mid July 2001: Official answer from ESA to the LoI. • September 2001: Telescope studies kick-off ==> interaction between Telescope and EddiCam • Summer - fall 2002: end of telescope, CCDs and mission studies. • End of 2002: EddiCam preliminary design and system specifications • Spring 2003: preliminary requirements review (PRR)==> start of Phase B launch in 2007/08!! . Córdoba, June 14th, 2001 J. Miguel Mas-Hesse