1 / 32

AMS-02 Magnetic Field Measurement

AMS-02 Magnetic Field Measurement. Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007. AMS-02 Magnetic Field. AMS-02 magnetic field measurement to identify the interior magnetic field by a servo system in planar scanning The exterior magnetic field is only identified by some specified locations.

hillmary
Download Presentation

AMS-02 Magnetic Field Measurement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AMS-02 Magnetic Field Measurement Prof. Chin E. Lin, NCKU, TNN TIM Jan. 09, 2007

  2. AMS-02 Magnetic Field • AMS-02 magnetic field measurement to identify the interior magnetic field by a servo system in planar scanning • The exterior magnetic field is only identified by some specified locations

  3. Fixture Design Concept

  4. Actual Fixture on Mockup

  5. Fixture Tests • We use wooden mock-up to carry on our calibration test and field measurement test at NCKU

  6. Mount Support on Mock-up

  7. Fixture on Mock-up in NCKU

  8. Fixture on AMS-01 Sensor in position

  9. Fixture on AMS-01 Sensor position calibration Hall Sensor Hall Sensor

  10. Magnetic Field Sensor • We use a SYPRIS Co. F. W. BELL Model 7030 Gauss/Tesla Meter, with 3D probe for 300 k Gauss(30 Tesla)in 1 m Gauss(0.1 μ Tesla)resolution

  11. Origin Calibration • Use laser pointer on both X and Y axes to project an intersection to identify as its origin of probe scanning

  12. Origin Calibration • Laser positioning calibration

  13. Field Mapping • AMS-02 magnetic field mapping will run a little more than one quarter of the overall interior volume, assuming the field distribution is x- and y- symmetrical. • Initially, we need to identify the symmetry by a few symmetrical locations • The servo system is controlled to run only one quarter. Otherwise, we have to do full plane mapping.

  14. Mapping Plane

  15. Where to Mount • On the original design, we found from the four mounting holes to use. • However, currently, the temp O-ring has four seal attachments using the same mounting holes. • Can they be shifted ?

  16. Fixture Mounting

  17. Temp O-Ring

  18. Considering O-Ring • We reduce the planar size to consider the temporary O-ring. The scanning distance is 80 mm less in diameter. • The scanning control software is adjustable to fit for O-ring.

  19. Measurement in SCL • We try to finish the AMS-02 interior field measurement within 7 days • We need to prepare 1-2 days before mounting on to AMS-02 • The fixture is about 500 lbs. We need help by a crane to lift it up.

  20. Fixture Shipping • The measurement fixture shipping to Oxford takes 6-8 weeks. • We will be ready anytime from today.

  21. AMS-01 Tests

  22. Fixture on AMS-01 Tests • We have used the measurement fixture to finish AMS-01 magnetic field measurement.

  23. Fixture on AMS-01

  24. AMS-01 Field Measurement

  25. A

  26. AMS-01 Data in Memory • Data acquisition from measurement system and store into database

  27. Measurement Axis

  28. A • A

  29. AMS-01 Magnetic Field Profile

  30. Exterior Measurement • Due to CSIST site constraint where AMS01 is located, we can only measure half spherical for less than 2 meters outside the main body • From an axis, locating at 120 degree, to both side with each step of 15 degree, at 1 meter and 1.5 meter from top to down