130 likes | 287 Views
THE RADIX TRAFFIC BELOW GROUND VEHICLE DETECTOR. RTM MAGNETOMETER COMPONENTS. Radix Sensor RTM300 3-axis magnetometer technology monitors changes in the Earth’s magnetic field caused by vehicles passing over it.
E N D
RTM MAGNETOMETER COMPONENTS • Radix Sensor RTM300 • 3-axis magnetometer technology monitors changes in the Earth’s magnetic field caused by vehicles passing over it. • The processor interprets these changes and determines whether to indicate a detection event based on sensitivity settings and other criteria. • Rugged IP68 rated cylindrical housing, nominally only 18mm diameter. Draw cord can be fitted to the housing for easy and quick retrieval. • 2-wire connection back to RTM500 Interface Card located at Signal Controller via new or existing loop feeder cable.
RTM MAGNETOMETER COMPONENTS • Radix Interface Card RTM500 • Standard 3U Eurocard rack mounting into TR2512 detector backplane. • Delivers power, signals, sensitivity and other parameters to, and receives detection event data from, the RTM300 sensor. • Each RTM500 card supports connection of up to four RTM300 sensors. • Front panel detect & fault LEDs switch off after a pre-determined time to save power and are restored by a quick press of the reset button. • User selectable front panel switches to select sensitivities and presence times for each sensor channel.
INSTALLATION SCHEMATIC RADIX RTM300 SENSOR INSIDE DUCT UNDER CARRIAGEWAY CONTROLLER EXISTING RACK WITH LOOP CARDS RADIX RTM500 INTERFACE CARD LOOP FEEDER LINKING RTM300 SENSOR TO RTM500 INTERFACE CARD DUCT ENTRY
INSTALLATION • The RTM300 Sensor is installed into cross carriageway ducting. • Ducts may be existing cable ducts at suitable road crossing points, or dedicated narrow bore ducts located nearer the surface. • Depending on the choice of duct diameter, it is possible to fit multiple sensors in one duct for detection in individual lanes. • Draw cords should be attached to each sensor to allow easy adjustment/removal.
INSTALLATION • The RTM300 Sensor is connected to the RTM500 Interface Card back inside the Traffic Controller using a 2-wire system via existing legacy or new loop feeder cable. • Connection to the feeder is made in the conventional manner and the use of a re-usable bottle joint is recommended for this purpose.
INSTALLATION • The RTM500 Interface Card is installed into a Standard 3U Eurocard Rack inside the Traffic Controller. • It is the same size as a standard loop detector card and fits into a standard TR2512 backplane.
SUMMARY The Radix RTM Magnetometer Vehicle Detector offers customers significant life cost savings over other below ground detection solutions.