An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introducing the Q-Series Outdoor Air Humidity Sensors!

  2. Q-Series Humidity Sensors – What’s So Exciting? • Room, duct and now outside air humidity sensors • Newly redesigned housing with a new look and feel • A variety of versions for many different applications • Signal options • Accuracy options • Many new features and accompanying benefits • Very serviceable! • Very affordable!!

  3. Q-Series RH Outdoor Air Sensors – Applications Use in all standard applications for building control: • General HVAC Installations • Energy Management Systems • Critical Environments • Enthalpy Control

  4. Q-Series RH Outdoor Air Sensors – Features • Offered as 2% or 2% certified versions • Removable, replaceable sensing tips • Available as RH sensing only or RH with Temperature • Voltage and current output signals available • Flexibility and ease of wiring connection

  5. Q-Series RH Outdoor Sensors – Housing • Small, sleek housing design – for tight-fitting spaces • Keyed housing cover • Siemens name and part number are laser-etched • On cover for clear viewing • On base, to correctly mate to cover if they become separated • UL Listed! • Specs printed on outside cover • Multiple conduit knockouts • Clearly labeled wiring terminations • Removable sun shield to protect sensor

  6. Q-Series RH Outdoor Air Sensors – Design Details • Jumper-selectable temperature ranges for better control • Conduit clamp included • Tighten down over 3/8” flex conduit to secure it to the housing • Reversible clamp allows for strain relief if jacketed wiring is used • Temperature-compensated element – superior accuracy! • Digital signal – minimizes reading errors

  7. Q-Series RH Outdoor Air Sensors – Accuracies and Control Signals • 2% Versions • Accuracy over the range of 0-95% relative humidity • Removable, replaceable sensing tips • 2% Certified versions • Matching bar code labels for housing base and tip • 3 Point temperature and humidity calibration • Replaceable tip ships with certification and label • Active signals for Humidity or Temperature • 0-10 Volts; may be powered by AC or DC Voltage • 4 to 20mA current

  8. Q-Series RH Outdoor Air Sensors – Competitive Summary X Offered -- Not Offered

  9. Q-Series RH Outdoor Air Sensors – Documentation • Specification Sheet – 149-992 • Installation Instructions – 129-416

  10. Q-Series RH Outdoor Air Sensors -Selling Arguments vs. Honeywell/Hycal HCT829 • Available as humidity only units • Does not measure accurately above 90%. • Only available in a 4-20 mA version. • Element does not recover well from 100% saturation. • Humidity element is not replaceable. • Honeywell offers no versions with certification

  11. Q-Series RH Outdoor Air Sensors -Selling Arguments vs. Johnson Controls (HE-67x3) • Does not offer a removable, replaceable tip • Only measures up to 90% relative humidity • Cannot measure at 4% accuracy or better over the 80% rh • On RH&T versions, sensor not temperature range selectable • Element may not recover from 100% saturation

  12. Q-Series RH Outdoor Air Sensors -Selling Arguments vs. Veris Industries HO Series • Veris sensors not UL listed • Product only measures accurately up to 90% rh • Devices not range selectable on temp versions.

  13. Q-Series RH Outdoor Air Sensors -Selling Arguments vs. ACI A/RHx-O types • Sensing element not removable or replaceable • Only accurate to 95% relative humidity • SBT’s device measures from 0-100% for the 2% model • ACI product not temperature range selectable • ACI does not offer a UL listed product

  14. Selling Arguments vs. GE/ General Eastern -Microline (MRH and MRHTx types) • No removable tip – must replace entire unit! • Measures over a 20-95% rh range only • MRHT products don’t have temperature range selectability • Poor accuracy Tests vs. GEI sensors under extreme conditions showed new Siemens sensors perform much better than Microline products!

  15. Q-Series RH Outdoor Air Sensors -Selling Arguments vs. Kele • Does not have their own product • Resells ACI, Hycal/Honeywell, Vaisala, and GEI products • Relies on service to gain market share

  16. Q-Series RH Outdoor Air Sensors -Selling Arguments vs. BAPI the BA/H200, BA/H300 • Only measures to 95% rh • Does not offer temperature range selectability • Does not offer certified sensors • Sensors are not UL listed • Element will not recover from 100% saturation

  17. Q-Series RH Outdoor Air Sensors Selling Arguments vs. Vaisala HMD60 or HMD70 • Does not offer temperature range selectable • Does not offer UL listed devices • Very expensive!! • For a much lower price, Siemens’ Q-Series humidity sensors • offer all the accuracy and reliability you need!

  18. Q-Series RH Outdoor Air Sensor – Doubles as a Critical Environment sensor!! • Critical Environment and Lab applications • Same 2% or 2% certified accuracy • May be washed down • Removable, replaceable tip • Lumberg fitting for conduit connect