1 / 14

Current Wireless Technology

Current Wireless Technology. Closed Circuit Television (CCTV) in Intensive Care Units Remote Alarms. Implanted Wireless Devices. Couple the sensor to the actuator Ex. Diabetic patients Glucose meter – implanted insulin pump Wireless Microchips Epilepsy Parkinson’s disease.

hua
Download Presentation

Current Wireless Technology

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Current Wireless Technology • Closed Circuit Television (CCTV) in Intensive Care Units • Remote Alarms

  2. Implanted Wireless Devices • Couple the sensor to the actuator • Ex. Diabetic patients • Glucose meter – implanted insulin pump • Wireless Microchips • Epilepsy • Parkinson’s disease

  3. Homecare • Continuous Monitoring of Physiologic Parameters • ECG • NIBP • SpO2 • Pill Boxes

  4. “SmartShirt” Georgia Tech Wearable Motherboard™ • Georgia Tech • Funded by U.S. military • Plastic optical fiber • T-connectors form flexible bus • ECG, RR, temperature • Ex. Geriatric / mentally ill / SIDS • Ex. Firefighting

  5. Plug-and-Play Interoperability WHY IT IS NEEDED: • Specialized applications / multiple vendors • Medical devices and clinical information systems • No time for configuration or set-up programs

  6. Plug-and-Play Interoperability FACTORS TO CONSIDER: • Safety • Unambiguous association • Reliability • HL7 Interoperability • Security • Scalability

  7. IEEE 1073 IEEE P1073.0.1.1/D01E Draft Guide for Health informatics – Point-of-care medical device communication – Technical report – Guidelines for the use of RF wireless technology (Unpublished)

  8. QoS Components Reliability Latency Priority Bandwidth (Subject to Change) Medical Device Data Categorization Alert notifications Real-time waveforms Real-time parameters Non-real-time parameters Non-real-time events Device control IEEE 1073Summary

  9. EXAMPLE: Real-time Alarm Very high reliability (100%) < 10 second latency Very high priority Low, intermittent bandwidth Real-time Waveform High reliability (10 s/day) Latency (?) High priority High, predictable bandwidth IEEE 1073QoS Requirements

  10. DEVICE SPECIALIZATION Infusion Pump Vital Signs Monitor Ventilator Pulse Oximeter Defibrillator ECG Blood Pressure Temperature Dialysis Device Airway Flowmeter Cardiac Output Capnometer Hemodynamic Calculator Pulmonary Calculator Respirator Weighing Scale www.ieee1073.org IEEE 1073EDITORIAL PLAN (v21)

  11. The Road Ahead? • Bluetooth – Coexistence research (ISM band) • Wireless Policy • State internal body for resolution of wireless issues • Procedure for inclusion of additional wireless networks

  12. References darbelofflab.mit.edu www.welchallyn.com/medical/ www.stryker.com www.ortivus.com www.flicscanner.com www.baxter.com www.emergin.com www.minimed.com www.freep.com www.research.ibm.com www.smartshirt.gatech.edu www.codebluecommunications.com www.ieee1073.org

  13. References (con’t) R. Schrenker and T. Cooper, “Building the Foundation for Medical Device Plug-and-Play Interoperability”, Available @ www.ieee1073.org IEEE P1073.0.1.1/D01E Draft Guide for Health informatics – Point-of-care medical device communication – Technical report – Guidelines for the use of RF wireless technology (Unpublished)

  14. Questions

More Related