1 / 13

EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)

EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX). Outline. 1. Introduction 2. G rounding strategy 2.1 . Implementations aspects 3. Noise emission issues Test plans 4. Noise immunity issues Test plans 5. Cabling 6.Conclusions. 1. Introduction.

idana
Download Presentation

EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)

  2. Outline • 1. Introduction • 2. Grounding strategy • 2.1. Implementations aspects • 3. Noise emission issues • Test plans • 4. Noise immunity issues • Test plans • 5. Cabling • 6.Conclusions

  3. 1. Introduction • Short description and schematic of each subdetector.

  4. 2. Grounding strategy • Outline of the grounding strategy • Information about current or previous grounding topology. • Single point, multipoint or other • Describe the actual or proposed grounding topology • Place a conceptual schematic. • Implementation • Electro-mechanical schematic • Type of grounding connection Bonding or straps? • Capacitors connections ? • ……. • Nest slides shows as an example some of this schematics for PXD system

  5. 2. Grounding strategy - Topology Hybrid Equivalent to Multi-point Multi-point For high level frequency circuits (above 1 MHz) Single-point Only for low level and low frequency circuits (below 1 MHz) • Hybrid ground topology is the preferred option as • FE amplifier bandwidth is very high – 100 MHz It prevents excessive radiated emissions and maintains low impedance Better filter performance PXD is very small but the FE Amplifier bandwidth is around100 MHz

  6. 2. Grounding strategy - Topology PXD Detector

  7. 2.1 Grounding strategy - Implementation • PXD connected to the cooling blocks via capacitors • High Frequency Ground Connection • Cooling blocks connected to Beam pipe ? through direct bonding. • Beam pipe connected to reference ground system. Cooling block Cooling pipe Detector (FEE) Beam pipe ? Referenceground

  8. 3. Noise emission issues • Emission issues. • Analysis of the main noise sources • Identification • Power supplies, slow control system or any other ??? • Test plans • Remark or comment the main noise sources for the subsystem • Type of noise • Conducted or radiated ? • Frequency • Possible coupling path • Test plans . • Noise emissions test plans ? • Show test results in case they have been already performed.

  9. 4. Noise immunity issues • Analysis of the main noise victims • Identification • Describe the signal detection circuit (Detector – FEE ) • Schematic • Frequency range where detector circuit expect to be sensitive. • Possible coupling path • Describe any other sensitive circuit you expect noise problems • Test plans . • Noise immunity test plans ? • Show test results in case they have been already performed. • Sensitive • Nest slides shows as an example some schematics of detection circuit for PXD system

  10. 4. Noise immunity issues – Signal circuit Pixel Signal CG S Vsource G Clear D Zin (Z??) Vamplow SignalReturn DCD

  11. 4. Noise immunity issues – Signal circuit Signal circuit: PXD

  12. 5. Cabling • Cabling and Shielding aspects • Type of cables ? • cabling layout ? • Cable connections ? • Grounding of cooling pipes ? • Any other relevant information

  13. 6. Conclusions