1 / 45

Imagerie de Diffusion Organes Mobiles et Corps Entier

Imagerie de Diffusion Organes Mobiles et Corps Entier. Alain Luciani , Frederic Pigneur , Emmanuel Itti , Alain Rahmouni CHU Henri Mondor, Universite Paris Est Creteil alain.luciani@hmn.aphp.fr. Imagerie Diffusion Corps entier – WB-DWI. Couverture anatomique . Imagerie Fonctionnelle.

iola
Download Presentation

Imagerie de Diffusion Organes Mobiles et Corps Entier

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Imagerie de Diffusion Organes Mobiles et Corps Entier Alain Luciani, FredericPigneur, Emmanuel Itti, Alain Rahmouni CHU Henri Mondor, Universite Paris Est Creteil alain.luciani@hmn.aphp.fr

  2. Imagerie Diffusion Corps entier – WB-DWI Couverture anatomique Imagerie Fonctionnelle « Tout en un »

  3. Comment je fais ? Antennes Séquences DWI-MRI • Pré-requis technologiques et instrumentaux Applications Cliniques

  4. Comment je fais ? IRM Corps entier « Fonctionnelle » • Imagerie Diffusion Corps entier (WB-DWI-MRI) • • Gradient directions ? • • What about breathing ? • Imagerie dynamique après injection de pdc(WB- DCE-MRI) • • Timing • • Plans de coupes « Anatomique » Plan Sagittal Coronal Axial Séquences T1 WI T2 avec suppression graisse Pré-requis ? Impact clinique ? Imagerie paramétrique ? Suppression Graisse Gestion artefacts de mouvements

  5. Comment je fais ? Antennes • Surface • Body Coil Acquisitions parallèles Résolution spatiale

  6. Comment je fais ? Antennes Antenne Corps Surface

  7. Comment je fais ? Séquences • Suppression graisse ? Homogénéité Temps d’acquisition FS STIR

  8. Comment je fais ? Séquences • Respiration • Libre + multiple Nex • Gating : Ceinture (pressure sensor) • Cycle respiratoire • Fin d’expiration => Acquisition • Trigger :

  9. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • Respiration : Impact sur WB – imaging ? • 10 volontaires • DWI SE EPI sequence • TE 76, b0 , 400s/mm2 • Respiration libre

  10. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • Variation intra-individuelle ADC ± 14% • Seuil de signification > 27%

  11. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • Respiration : Impact sur WB-DWI ?

  12. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • Nombre de gradients de diffusion ? Mêmes paramètres ; Nex=2

  13. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • Choix des valeurs de b ?

  14. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • Choix des valeurs de b ? • b 0, 500, 1000 s/mm2 • Modèle animal CCl4

  15. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI Diffusion moléculaire Composante perfusive Principes de la diffusion

  16. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI Diffusion moléculaire Microcirculation Composante perfusive b<100s/mm2 : composante perfusive non négligeable b>100s/mm2: composante perfusive négligeable Principes de la diffusion

  17. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI Application clinique

  18. Comment je fais ? b = 0 s/mm2 b = 50 s/mm2 Séquences Diffusion WeightedWhole Body MRI • Choix du facteur b • T2 WI • Limite effet « perfusion » • Filtre vitesse Koh DM et al. AJR 2007;188:1622-1635

  19. Comment je fais ? Séquences Diffusion WeightedWhole Body MRI • 1.5 T ou3 T ? • Temps d’acquisition • Artefacts

  20. Comment je fais ? Séquences Messages Clés • Antennes • Imagerieparallèle • Gating respiratoire • Suppression graisse • Injection ? • DWI imaging : • TR/TE • Direction de gradients • Epaisseur de coupe / Gap • Choix des valeurs de b

  21. Example de protocole WB-DWI Temps d’acquisition : 20 – 45’ Whole Body Scout View Sagittal T1 SE Coronal T2 TSE FS / STIR (2 à 3 Steps) (HASTE / Transverse TSE - > Lung) 4. DWI : Transverse DWI : 50,400,800s/mm2; TE=76ms 5. Transverse 2D EG T1 FS / Dixon / Water excitation 5mm

  22. Applications cliniques Données de la littérature : Abondante mais hétérogène ! Instrumentation et type de tumeurs • Staging tumeur primitive : débattu -> Instrumentation • Antoch et al. JAMA 2003; 98 patients ; variousPrimary; Accuracy PET-CT (80%) > WB-MRI (52%) • Yi et al. Radiology 2008; 165 patients; NSCLC; Accuracy T staging WB MRI (86%) > PET-CT (82%) • Screening et détection tumorale • Fischer et al. EurRadiol 2011; 21:246-255 • 68 patients staging of malignantTumor by PET-CT (Ref Standard) • Concomitant WB-MRI (T2 + DWI b =0 / b= 700s/mm2) • Accuracyoverall 82% reaching 91% for liver mets • Métastases osseuses • Mélanome : Laurent et al. Eur J Radiol 2009; Epub • Se IRM (DWI) = 82 % vs. 72% PET-CT • Sp IRM (DWI) = 97% vs. 92% PET-CT • Cancer Prostate : R Venkitaraman et al. J Med Imaging Rad Oncology 2009;53:530-533 • 39 patients • MRI > 99mTc • Cancer poumon (NSCLC): Takenaka et al. J. Magn. Reson. Imaging 2009;30:298-30 • 209 patients • MRI (DWI) > 99mTc and PET-CT ……………. • HematologicMalignancies

  23. Applications cliniques WB-DWI-MRI et Lymphome • Takahara et al Radiat Med. 2004

  24. Applications cliniques WB-DWI-MRI et Lymphome

  25. Applications cliniques WB-DWI-MRI et Lymphome • Protocol • Philips Achieva® • Surface coil • Free breathing • SS SE EPI 8612/78ms • b= 0 – 1000s/mm2 • + STIR T2 / T1 • Staging comparé avec TDM

  26. Applications cliniques WB-DWI-MRI et Lymphome • Meilleure Se / TDM • Moelle osseuse • Atteinte extra digestive

  27. Applications cliniques 1.5T Henri Mondor WB-DWI-MRI et Lymphome Surface Coils (76 elements) • SNR • Parallel acq; facteur 2 Gating respiratoire • TR = Cycle respiratoire • ADC maps

  28. Applications cliniques ADC b50 CT PET PET/CT Detection – Staging ganglionnaire WB-DWI-MRI et Lymphome b800 • 94% des ggsdétectés en WB-DWI-MRI et TEP TDM • 89% des airesggs positives en TEP TDM ont diffusion restreinte

  29. Applications cliniques Detection – Staging Ganglionnaire WB-DWI-MRI et Lymphome b50 b800 ADC •Résolutionspatiale en WB-DWI =ggou masse ?

  30. Applications cliniques WB-DWI-MRI et Lymphome Atteinteprofonde b50 b800 T2WI

  31. Applications cliniques WB-DWI-MRI et Lymphome Atteinteprofonde b800 b800 ADC

  32. Applications cliniques b800 ADC b50 b800 ADC b50 WB-DWI-MRI et Lymphome • 23 y/o patient DLBCL Mediastin • 4 cycles de CT : Masse résiduelle 8x1cm (CRu) mais TEP TDM négatif => CR • Pas de diffusion restreinte

  33. Applications cliniques WB-DWI-MRI 3T et Lymphome b50 ADC 51 y/o DLBCL Initial Staging 3T WB DWI Siemens Verio® SE EPI STIR WE b 50, 400, 800s/mm2 b800

  34. Applications cliniques WB-DWI-MRI 3T et Lymphome b50 54 y/o DLBCL Initial Staging 3T WB DWI Siemens Verio® SE EPI b 50, 400, 800s/mm2 b800

  35. Applications cliniques WB-DWI-MRI 3T et Lymphome b50 54 y/o DLBCL 6 cycles CT b800

  36. Applications corps entier 3D VIBE • Combined WB-DCE MRI and WB-DWI-MRI in Lymphoma 54 y/o DLBCL Initial Staging Stage IV (Bone) b50 T2 WI ADC map

  37. Applications cliniques Approche foncitonnelle combinée 54 y/o DLBCL Initial Staging Stage IV (Bone) b50 ADC map b800 b800

  38. Applications cliniques WB-DWI-MRI 3T et Lymphome 54 y/o DLBCL Initial Staging Stage IV (Bone) b50 ADC b800

  39. Clinical Applications • Combined WB-DCE MRI and WB-DWI-MRI in Lymphoma b50 ADC 54 y/o DLBCL After6 cycles CT b800

  40. Messages • Instrumentation • Instrumentation • Instrumentation

  41. 1 2 3

  42. Applications cliniques • Pas encore définies …. • Standardisation ? • Sélectionner études cliniques adaptées….