1 / 10

Mauthe Center Solar Project

Mauthe Center Solar Project. NWTC Solar Advanced System Design Class. Possible Mounting Options. Flat roof Portrait Landscape Pole Mount With Tracking With Out Tracking. Possible Array Locations. Energy Consumption. Annual electrical consumption: 63,000 kWh/ yr

iola
Download Presentation

Mauthe Center Solar Project

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mauthe Center Solar Project NWTC Solar Advanced System Design Class

  2. Possible Mounting Options • Flat roof • Portrait • Landscape • Pole Mount • With Tracking • With Out Tracking

  3. Possible Array Locations

  4. Energy Consumption • Annual electrical consumption: 63,000 kWh/ yr • To completely offset consumption a 52 kW system would be needed • Estimated cost for a 52 kW system (roof mount): $210,000 - $300,000* • Estimated cost for a 52 kW system (pole mount): $312,000 - $410,000* • * cost may vary depending on actual infrastructure requirements

  5. Your Budget • An approximate 6 KW ballasted roof mount PV system would be in line with your $30,000 budget. • This PV system would offset a little over 10% of your present electrical consumption. • A 6 KW PV system would meet the electrical needs for a conservative household. (8 KW would be for the typical household) • A 6 KW PV system would produce approximately 7200 KWH/ year.

  6. Energy Efficiency • Concentrate on energy efficient methods • Ex. Turn off lights, close doors, sectional heating/cooling, occupancy sensors, use natural lighting, power strips, etc. • Replace inefficient components of building • Ex. Furnace, air supply, lighting, windows, insulation, etc.

  7. Flat Roof Design • 6 kW system • Ballasted Racking = No moving parts & easy to maintain • Landscape modules to minimize wind load • Minimal shading for maximum production • Estimated annual production: 7,200 kWh/ yr • Estimated cost: $24,000 - $36,000

  8. Pole Mount Front of Building • 3kW • Minimal shading to maximize output • Increased cost of pole mount = less solar modules • Great visibility/ public awareness • Estimated annual production: 3,600 kWh/ yr • Estimated cost: $18,000 - $24,000

  9. Pole Mount Behind Building (exceeds budget) • 6kW • Minimal shading to maximize output • Tucked away/ less visible • Estimated annual production: 7,200 kWh/ yr • Estimated cost: $36,000 - $48,000

  10. SOLAR ENERGY • PROVIDING A BRIGHT FUTURE • ENVIRONMENTALLY SOUND ENERGY • DISTRIBUTED ENERGY BENEFITS / LOCAL JOBS / LOCAL ENERGY / KEEPS OUR ENERGY DOLLARS IN OUR COMMUNITY. • OFFSETTING FOSSIL FUEL CONSUMPTION • SIMPLE / RELIABLE / DURABLE / LONG LIFE