1 / 8

Zeiss 15 APLICACIONES.

Microscopio de Luz Transmitida -Campo Claro -Contraste Interdiferencial (DIC) -Contraste de Fases (PH). Zeiss 15 APLICACIONES. Microscopio de Fluorescencia Filtros : 1-DAPI 9-VERDE 15-ROJO 25-TRIPLE. Localización : Microscopía Planta – 1. Filtros Fluorescencia: 1-Azul :

ipo
Download Presentation

Zeiss 15 APLICACIONES.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Microscopio de Luz Transmitida -Campo Claro -Contraste Interdiferencial (DIC) -Contraste de Fases (PH) Zeiss 15 APLICACIONES. Microscopio de Fluorescencia Filtros : 1-DAPI 9-VERDE 15-ROJO 25-TRIPLE Localización : Microscopía Planta – 1

  2. Filtros Fluorescencia: 1-Azul : (360/40x) FT 395 LP397 9-Verde: (450-490) FT510 BP 525/50 15-Rojo: BP 546 FT 580 LP 590 25- Triple: BP(400/495/570) FT (410/505/585 ) TBP (460/530/610) Zeiss 15 CARACTERISTICAS. Objetivos : x10 (Sin Fase) (DIC) x20 (Fase 2) (DIC) x40 oil (Sin Fase) (DIC) x63 oil (Fase 3) (DIC) x100 oil (Fase 3) (DIC) Filtros/Anillos DIC: -DIC I -DIC II -DIC III Filtros/Anillos Fases: -Ph 2 -Ph3 Condensador : 0,9 Equipo conectado : -Cámara Hamamatsu (c4742-95). -AttoArc HBO 100 W . -Mac Power G4. -Motorización ORBIT. Programa OPENLAB asociado

  3. Binoculares NOTA : Zeiss15 incluye filtros de fluorescencia que se pueden usar de 2 modos: -Modo manual -Modo automatizado 1-Para usar los filtros manualmente se debe colocar en la rueda de filtros(**) del microscopio el filtro deseado de forma manual 2- Para usar el sistema automátizado de filtros , se debe colocar la rueda de filtros en la posición “arcoiris/automatizado” , los filtros se introduciran de forma automatica usando los botones del controlador “Orbit” Barra DIC/Fases. 2 posiciones: -para ver en DIC -para ver en Fases (**)Rueda Filtros Fluorescencia -Azul/Dapi -Verde -Rojo -Triple Protector Visor Fluorescencia (móvil) Orbit : controlador motorizado de filtros fluorescencia Objetivos x10 x20 x40 oil x63 oil x100 oil Platina Rueda DIC/Fases -DIC: I, II, III -Fases (Ph):II, III Condensador Obturador luz Transmitida Polarizador DIC Micro y macro

  4. OCTOBAR (re-amplia el objetivo seleccionado hasta x2,5) Barra DIC/Fases. 2 posiciones: -para ver en DIC hacia adentro -para ver en Fases hacia afuera Ajuste Lámpara Hg Barra Filtro.3 posiciones: IR /Vacío / ObturadorFluorescencia Protector/Visor de Fluorescencia Diafragma Campo Fluorescencia Diafragma Apertura Fluorescencia Revolver Objetivos x10 x20 x40 oil x63 oil x100 oil Condensador Bloqueo Nivel Luz transmitida Lámpara Luz Transmitida Interruptor Encendido Regulador Luz Rueda DIC/Fases: -DIC: I,II,III -Fases PH:II,III Diafragmas campo BF Rueda Filtros Fluoresc. Azul/verde/rojo/triple Micro y macro -Obturador BF -Polarizador Diafragma apertura BF

  5. Cámara Hamamatsu Cámara fotográfica Binoculares Puerto accesorio Barra DIC/Fases. 2 posiciones : -para ver en DIC hacia dentro -para ver en Fases hacia fuera Rueda Filtros Fluorescencia: -azul -verde -rojo -triple Protector Fluorescencia para observador Revólver Objetivos x10 x20 x40oil x63oil x100oil XY platina Rueda DIC/ Fases -DIC: I, II, III -Fases (Ph): II, III Obturador Luz transmitida Micro y macro Polarizador DIC (aplicar para ver en DIC)

  6. Protector de fluorescencia para observador Diafragma Apertura Fluorescencia Objetivos x10 x20 x40oil x63oil x100oil Platina XY platina Ajuste Kohler Diafragma de campo BF Rueda DIC y Fases: -DIC: I, II, III -Fases(PH):II, III Obturador Luz TRANSMITIDA Micro y macro Polarizador DIC (aplicar para ver en DIC)

  7. Fluorescencia : Abre o corta la fluorescencia Luz Transmitida: pasa a modo de luz transmitida No activo Botonera Filtros de fluorescencia: Dapi/ verde /rojo /triple Movimiento filtros: permite el movimiento de los filtros hacia posiciones anterior y/o posterior Orbit: encender para usar el control motorizado de los filtros de fluorescencia No activo Permite pasar a modo control manual en que los filtros se cambian moviendo la rueda de filtros ( situada sobre el revólver de objetivos) NOTA : Zeiss15 incluye filtros de fluorescencia que se pueden usar de 2 modos: 1-Modo manual 2-Modo automatizado 1-Para usar los filtros manualmente se debe colocar en la rueda de filtro del microscopio el filtro deseado de forma manual 2- Para usar el sistema automatizado de filtros , se debe colocar la rueda de filtros en la posición “arcoiris/automatizado” , los filtros se introduciran de forma automatica usando los botones del “Orbit”

  8. Unidad de Microscopía Centro de Investigación del Cáncer Campus Miguel de Unamuno 37007 Salamanca (Spain).

More Related