1 / 8

Zeiss 16

Zeiss 16. Fotoguía. Microscopio de Luz Transmitida -Contraste Interdiferencial (DIC) -Contraste de Fases (PH) -Campo Claro. Zeiss 26 APLICACIONES. Microscopio de Fluorescencia Filtros : 1-DAPI 9-VERDE 15-ROJO 25-TRIPLE. Localización : Microscopía Planta – 2.

Download Presentation

Zeiss 16

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Zeiss 16 Fotoguía

  2. Microscopio de Luz Transmitida -Contraste Interdiferencial (DIC) -Contraste de Fases (PH) -Campo Claro Zeiss 26 APLICACIONES. Microscopio de Fluorescencia Filtros : 1-DAPI 9-VERDE 15-ROJO 25-TRIPLE Localización : Microscopía Planta – 2

  3. Filtros Fluorescencia: 1-Azul : BP 365 FT 395 LP397 9-Verde: (450-490) FT510 LP 520 15-Rojo: BP 546 FT 580 LP 590 24- Triple: TBP(400/495/570) FT (410/505/585 ) TBP (460/530/610) Zeiss 26 CARACTERISTICAS. Objetivos : x1,25 (Sin Fase ni DIC) x5 (Sin Fase ni DIC) x10 (Fase 1) x20 (Fase 2)(DIC 1) x40 oil (Sin Fase)(DIC) x63 oil (Fase 3)(DIC 3) Filtros/Anillos DIC -DIC I -DIC II -DIC III Filtros/Anillos Fases -Ph1 -Ph 2 -Ph3 Condensador : 0,9 Equipo conectado : -Cámara color baja resolución MTI - Monitor tiempo real SONY -Iluminador NAG f HBO 50 -PC

  4. Cámara MTI Cámara fotográfica (no usada) Lámpara Hg Octobar (reamplia la imagen hasta un factor de x 2.5) Colimador Lámpara Hg Barra Analizador DIC (para ver DIC): -Activado para adentro -Desactivado para afuera Barra Filtros. 3 posiciones : -Vacío -IR -Obturador Fluorescencia Diafragma Apertura Fluorescencia Binoculares Puerto expansión (no usado) Diafragma Campo Fluorescencia Rueda Filtros Fluorescencia Revólver Objetivos Protector (móvil) de Fluorescencia Para Observador Interruptor Encendido Bloqueador del nivel de luz transmitida Regulador intensidad Luz Transmitida (BF) Rueda DIC y Fases Diafragma campo BF XYplatina Diafragma apertura BF Micro y macro

  5. Rueda Filtros Fluorescencia: 1-AZUL 9-VERDE 15-ROJO 25-TRIPLE Placa (móvil) protectora de fluorescencia para observador Condensador Revolver Objetivos: x1,25 x5 x10 x20 x40 oil x63 oil XY platina Micro y macro Rueda DIC y Fases: -Fases (Ph): I, II, III -DIC: I, II, III Ajuste platina Polarizador (debe aplicarse para ver DIC junto con barra DIC superior)

  6. Cámara MTI Binoculares Rueda Filtros: 1-DAPI 9-VERDE 15-ROJO 25-TRIPLE Cámara Fotográfica (no usada) Revolver Objetivos: x1,25 x5 x10 x20 x40oil x63oil Barra DIC/Fases Barra AJUSTE Lámpara Hg Protector Fluorescencia Rueda DIC y PH: -Fases (PH): I, II, III -DIC: I, II, III Micro y macro Platina Ajuste Kohler

  7. Cámara MTI Cámara fotográfica Condensador Barra Analizador DIC (para ver DIC): -Activado para adentro -Desactivado para afuera Filtros Fluorescencia: 1-DAPI 9-VERDE 15-ROJO 25-TRIPLE Protector (móvil) Fluorescencia Revolver Objetivos: x1,25 x5 x10 x20 x40 oil x63 oil Platina Bloqueador intensidad luz transmitida Rueda DIC y PH -Fases (PH):I, II, III -DIC: I, II, III XY platina Polarizador DIC (aplicar para ver DIC junto a la barra analizador DIC) Micro y macro

  8. Unidad de Microscopía Centro de Investigación del Cáncer Campus Miguel de Unamuno 37007 Salamanca (Spain).