170 likes | 530 Views
Veltrup Technik Philippines, Inc. Manila, Philippines. Presentation for. Cleaning of B ig Supply lines. Diameters of 25” – 36”. The Roto-Fan system of Veltrup Technik Philippines, Inc. can provide custom-made solutions for big pipelines !. Jobs performed earlier in comparable pipelines.
E N D
Veltrup Technik Philippines, Inc. Manila, Philippines Presentation for Cleaning of Big Supplylines Diameters of 25” – 36” The Roto-Fan system of Veltrup Technik Philippines, Inc. canprovide custom-made solutions for big pipelines!
Jobs performed earlier in comparable pipelines ID 800 pipe clogged with fly ash by 80% over a length of 400 m • ID 800 sewage pipe in Singapore incrusted with sewage residues by 5 – 8” like silica and calcium deposits which are very hard ID 700 – 1200 mm lines in Berlin incrusted with town gas residues ID 1400 mm water supply line in Poland incrusted with calcium deposits The task at all above lines was to bring the lines back to bare metal and orig. ID That task was achieved in all four lines above with the Veltrup Roto-Fan system
Before Cleaning After Cleaning Cleaning of ID 300 mm Glycerin line Product change possible without contamination of new product Cleaning brings line back to orig. ID Avoids contamination of new product
The Task was to clean out this incrustation which consists of calcium deposits Job performed in Poland on a ID 1400 mm water supply line
Pits done at approx. every 300m To create proper access points for the system The line had to be cut every 300 m to provide proper access for the Roto-Fan System
High pressure host Suction truck for water removal Suction hose Further more had to be a suction truck in place to remove the water out of the line
Nozzles in action Special device design for high cutting speed • A special device had to be designed to achieve high speed cleaning up to 100 meters per 12 hour shift
Runway for the Roto-Fan Forward Unit • Furthermore the surrounding area had to be prepared for the use of the Roto-Fan
Debris after cleaning to be removed from the pipeline Removal by Crane 3.6 mt of Debris removed out of 1000 meter line Removal of Debris
Cleaned Pipe Surface Before Cleaning Joint of pipe Cleaned surface Not cleaned side The Results Comparison in low contaminated area
Bare Metal ( White scale is SS color ) Before Cleaning After Cleaning Cleaning of Heat exchanger 1 mm incrustation will reduce heat transfer by 50% Heat exchange rate will be back to 99% after cleaning
VELTRUP Reference Source : www.cheresourres.comChemical Engineer Resources Website
Blocked Pipe Before Cleaning Cleaned to original ID After Cleaning Cleaning of clogged pipes
Cleaning of Evaporator upwards from the bottom Cleaning of Glycerin run down line to tank 32 Cleaning of Evaporator feeding line All cleaning done in-situ, no removal of equipment required
Our team ready to solve your Pipe Cleaning Problems
Summary The Roto Fan System is able to clean your pipes back to bare metal The cleaning can be done in-situ, that saves money and time for dismantling Due to the fully automatic system the cleaning will be done very fast and efficient Pipes which has to be dismantled before and scraped can be cleaned now
Veltrup Technik Ltd. Manila, Philippines The results speak for themself Thank you for using our services