1 / 14

'36 G' Gas Valve

'36 G' Gas Valve. New Valve White Rodgers 36G. Old Valve/Replacement Valve ‘36F’. 36G22 Gas Valve Non-Direct Vent. Nylon plug No barb fitting. 36G Gas Valve. 36G22 Gas Valve Direct Vent . Pressure “IN” Test Port. Manifold “OUT” Pressure Test Port. Pressure Adjust. Vent Port.

isleen
Download Presentation

'36 G' Gas Valve

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. '36 G' Gas Valve

  2. New Valve White Rodgers 36G Old Valve/Replacement Valve ‘36F’

  3. 36G22 Gas Valve Non-Direct Vent Nylon plug No barb fitting 36G Gas Valve

  4. 36G22 Gas Valve Direct Vent Pressure “IN” Test Port Manifold “OUT” Pressure Test Port Pressure Adjust Vent Port 36G Gas Valve

  5. 36G Single Stage Gas Valve 36E/F Single Stage • Out with the “Old”, In with the “New” Gemini Platform 36G Single Stage

  6. Gemini Flow Path Single Stage

  7. Gemini Service Features 36G Single Stage Adjustable Regulator ON/OFF Switch Vent Inlet Pressure Tap Outlet Pressure Tap

  8. 36G Two Stage Gas Valve • Out with the “Old”, In with the “New” Gemini Platform 36G Two Stage 36E Two Stage

  9. Gemini Flow Path Two Stage

  10. Gemini Service Features 36G Two Stage Two Adjustable Regulators (Low & High) ON/OFF Switch Vent Inlet Pressure Tap Outlet Pressure Tap

  11. LP GAS CONVERSION BAYLPKT210A LP Kit BAYLPKT210B LP Kit BAYLPSS210B LP Kit

  12. Gas Valve cont. • Adjusting valve “G” See Note: When converting to LP (spring goes in HI side only) you must first turn HI fire adjustment spring clockwise till it bottoms or you will not be able to adjust LO fire. • What units have “G” valve on them???? • *UY & *DT-R-A • What unit can the “G” valve be used as a replacement on???? • *UD & *DD-R-A PAGE 30