1 / 6

OSPF Extensions for MPLS Green Traffic Engineering draft-li-ospf-ext-green-te-01

OSPF Extensions for MPLS Green Traffic Engineering draft-li-ospf-ext-green-te-01. Gang Yan, Jianjun Yang, Zhenbin Li Huawei Technologies IETF 88, Vancouver, BC, Canada. Introduction. draft-li-ospf-ext-green-te-00 has been proposed in IETF 86.

ita
Download Presentation

OSPF Extensions for MPLS Green Traffic Engineering draft-li-ospf-ext-green-te-01

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. OSPF Extensions for MPLS Green Traffic Engineeringdraft-li-ospf-ext-green-te-01 Gang Yan, Jianjun Yang, Zhenbin Li Huawei Technologies IETF 88, Vancouver, BC, Canada

  2. Introduction • draft-li-ospf-ext-green-te-00 has been proposed in IETF 86. • The architecture of Central Controlled IGP has been proposed in [I-D.li-rtgwg-cc-igp-arch-00]. • Energy Saving can be a useful usecase for Central Controlled IGP.

  3. MPLS TE vs. MPLS Green TE • MPLS TE is used to optimize the efficiency of network. • More constraints are included: Bandwidth, Color, TE Metric, SRLG…… • CSPF will calculate the path at first. Then RSVP-TE will make the tunnel. • Does CSPF also consider the energy consumption of each link in the network?  MPLS Green TE • 100M/100W • 100M/100W • ? • 100M/50W • 100M/50W • 50M/50W • 50M/50W

  4. Centralized MPLS Green TE • IGP-based Central Controlled framework can be used for MPLS Green TE: • IGP controller collects energy consumption info through IGP extensions. • Reasonable energy-saving path computation based on complete topology information and state information of the whole network. • Ordered Traffic Switch to energy-saving path by Central Controller.

  5. OSPF Extensions • OSPF TE link LSA should be extended. • The new TLV will be named as "Energy consumption of Link TLV“. It is used to represent the energy will be consumed by the link. • Its unit is Watts. • 0 1 2 3 • 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 • +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ • | Type(TBD) | Length = 4 | • +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ • | Energy consumption of link | • +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ • The information will be flooded through the OSPF area with TE Link LSA.

  6. Next Steps • Algorithm research on energy-saving path computation and traffic switch. • Solicit comments and feedback on the draft. • Revise the draft.

More Related