Universal Fault Interrupter (UFI) Application: Center Tank Override Pump Auto Shutoff with Ground & Arc Fault Protection. UFI Technology Fuel System Protection. Relay sized, microprocessor based monitoring device adaptable to control center tank override pumps on B737, B757, B767, & B747
E N D
Universal Fault Interrupter (UFI) Application: Center Tank Override Pump Auto Shutoff with Ground & Arc Fault Protection
UFI Technology Fuel System Protection • Relay sized, microprocessor based monitoring device adaptable to control center tank override pumps on B737, B757, B767, & B747 • Provides pump dry-run protection within FAA specified 15 second window • Comprehensive electrical fault protection • Line-to-Line • Line-to-Ground • Intermittent opens (wires, connectors) • Phase imbalance • Other out-of-range conditions such as locked rotor, & bearing wear • Downloadable history database • No scheduled maintenance
UFI TechnologySystem Features • Fully certified to meet Amendment 25-102 without exceptions • UFI Hardware DO-254, Software DO-178B, Both to assurance level B • Satisfies two of three SFAR 88 regulatory requirements • Passive monitoring – can not introduce electrical signals into fuel tank wiring • Actively controls fuel pump relay • Reliability greater than existing system components, MTBF >100K hours (calc) • Non-intrusive installation, piggy-back or close proximity to existing pump relay • Transparent operation, crew reset-able • Technology adaptable to any 3-phase synchronous pump motor
UFI TechnologyDevelopment Status • FAA Certified December 2005 to Amendment 25- 102, latest fuel tank safety requirements, granted STC # ST01844LA (Boeing 737-300) • Installation development and certification for B757, B737NG, & B767 in work. • Remote mounting and universal voltage adapter (RAM) added to accommodate any relay or panel space configuration • Expansion capability: • Adaptable to meet future regulatory requirements resulting from SFAR 88
UFI Technology‘How Stuff Works’ • The UFI is a micro computer device which monitors the three phase wiring to the center tank pumps. • The UFI is an in-the-loop device between the cockpit switch and the pump control relay. • Each time the pump switch is energized the UFI checks for pump and wiring fault conditions. • Any time the UFI detects a fault condition it will remove power to the pump relay. • The cockpit crew will be alerted to the fault by a ‘pump pressure low’ indication. • Two UFI’s are required for complete center tank protection. • One for each pump relay.
UFI Technology - Block Segmentation Unique to “microcontroller” detection path Unique to “hardware” detection path Common to both detection paths Common circuits and Relay Control (FET)
UFI Technology Example of Run-Dry Electrical Signature Current Trace of Fuel Pump Dry-Run Condition
UFI Technology Example of Run-Dry Electrical Signature, (event continued) Last current surge above predetermined threshold. Dry-Run Delay Power Removal Current Trace of Fuel Pump Dry-Run Condition
UFI Technology Examples of System Level Testing Pump Startup Current APU Load Transient GPU – APU Switchover
UFI Technology Repetitive Auto Shutoff Testing Auto Shutoff @ Inlet Uncovered Note: Independent detection. Shutoff sequence not tied to fuel pump pressure determination or other less-reliable aircraft systems.
UFI Technology Ground Fault Protection Demonstrated Line to Ground Fault Detected Note: Power removed at control relay. Electrical surge not continued upstream to circuit breaker.
UFI Technology Arc Fault Protection Demonstrated Line to Line Fault Detected Fault mitigated locally regardless of whether origination occurred upstream or downstream of control relay.
FAA Comments Regarding Project No. ST10777LA-T • “Based on the review of the UFI 3000 design and system safety assessment the FAA credits the following attributes to the UFI 3000 functionality, effecting the airplane electrical fuel pump system: • Transient Fault Detection • 1) Line-to-ground current (parallel fault) • 2) Line-to-line current (parallel fault) • 3) Opened phase (series fault) • Steady-State Fault Detection • 1) Unbalanced phase currents • 2) Out-of-range phase currents • C) In response to any of the above electrical faults the UFI 3000 will de-energize the airplane electromechanical relay to shutoff the fuel pump. • D) Fuel Pump Auto-Shutoff. The UFI 3000 will de-energize the airplane electromechanical relay to shutoff the pump in response to pump inlet being uncovered, uninterrupted for fifteen (15) seconds”. • “Upon review of the applicants position and supporting documentation, the FAA finds that the applicant meets all the applicable requirements including compliance with 14 CFR 25.981 amendment 25-102, for the installation of UFI 3000 in Boeing 737-300 airplanes center wing tank pumps.” (Issue Paper)
SFAR88 & 14 CFR Part 25 §25.981 Amendment 25-102 • What is SFAR88? – It is a recently adopted Rule that requires design approval holders of certain turbine-powered transport category airplanes, and of any subsequent modifications to these airplanes, to substantiate that the design of the fuel tank system precludes the existence of ignition sources within the airplane fuel tanks – It also requires developing and implementing maintenance and inspection instructions to assure the safety of the fuel tank system – For new type designs it requires compliance to 14 CFR Part 25 § 25.981 Amendment 102 The FAA has indicated that terminating actions will be mandated to existing AD’s. Georgios Roussos, FAA Aerospace Engineer, ANM-130S Presentation: 2003 Seattle ACO DER Seminar November 4, 2003