370 likes | 749 Views
FBC, 2007, Changes. New Labeling Requirements for Hurricane Protection Products Effective March 1, 2009. Products to be Labeled. Skylights Exterior Windows and Glass Doors. Garage Doors Impact-Resistant Coverings. Products to be Labeled (Cont
E N D
1. Florida Building Code 2007 Changes of Interest to Hurricane Protection Industry
2. FBC, 2007, Changes New Labeling Requirements for Hurricane Protection Products
Effective March 1, 2009
3. Products to be Labeled Skylights
Exterior Windows and Glass Doors
4. Garage Doors
Impact-Resistant Coverings
5. Types of Labels Permanent Label Defined
Permanent label is a label that cannot be removed without noticeable damage
6. Types of Labels (cont…) Temporary Supplemental Label Defined
Temporary Supplemental Label has to be printed and supplied by the manufacturer to help inspectors identify the product
7. Require a Permanent and Temporary Label
Permanent Label
limited to one design pressure rating per reference standard per label.
Skylights, Exterior Windows and Glass Doors
8. Skylights, Exterior Windows and Glass Doors (cont…) The Permanent label shall identify:
the manufacturer
performance characteristics
Product’s model/series#
Approved product certification agency, testing lab, evaluation entity or NOA# to indicate compliance with the relevant standards.
9. Skylights, Exterior Windows and Glass Doors (cont…) Temporary Supplemental Label
Temporary Label has to be printed and supplied by the manufacturer
10. Skylights, Exterior Windows and Glass Doors (cont…)
11. Skylights, Exterior Windows and Glass Doors (cont…) glazing thickness
indicate impact rated if applicable
FL# or NOA # if applicable, and applicable test standard
The supplemental label is limited to one design pressure rating per reference standard per label
12. Skylights, Exterior Windows and Glass Doors (cont…) The permanent Label shall become the default if the temporary label is missing or no longer legible
13. Permanent Label Required
14. Garage Door (cont…) The Permanent Label shall identify:
the manufacturer
garage door model/series #
the positive and negative design pressure rating
indicate impact rated if applicable
the installation instruction drawing reference#
15. Garage Door (cont…) FL Approval # or NOA# if applicable
the applicable test standards.
Label may also contain in a checklist format required garage door components for an approved garage door assembly.
16. 1714.8.1 Labels
A permanent label shall be provided by the product approval holder on all impact-resistant coverings.
17. 1714.8.2 The following information shall be included on the labels on Impact-Resistant Coverings:
Product Approval Holder name and Address
Impact-Resistant Coverings (cont…)
18. All applicable methods of approval. Methods of approval include, but are not limited to Miami-Dade NOA; Florida Building Commission, TDI Product Evaluation; ICC-ES
Impact-Resistant Coverings (cont…)
19. The test standard or standards specified at Section 1609.1.2, including standards referenced within the test standards specified at Section 1609.1.2 used to demonstrate code compliance.
Impact-Resistant Coverings (cont…)
20. For products with a Florida Product Approval Number or Miami-Dade County Building Code Compliance Office (BCCO) Notice of Acceptance (NOA), such numbers shall be included on the label Impact-Resistant Coverings (cont…)
21. Accordion Shutters Bottom of locking bar or center mate facing exterior or outside
25. Bahama Awning or Colonial Hinged On the bottom, placed on the back of the shutter
28. Roll Shutter Bottom of the hood facing the exterior or outside or on the bottom slat facing the exterior or outside
31. OPTION #1: Metal and plastic panels Label may be embossed or printed
Label spaced not more than every 3 lineal feet on each panel
Label applied by holder of product approval
Label shall face the exterior
32. OPTION #2: Metal and plastic panels Permanent self adhering label
One label per panel
Label provided by holder of product approval
Label shall face the exterior or outside
33. This is incorrect. If a printed or embossed or watermark label was used, the printing, embossing, or watermark would be required every three feet. If a permanent label is used, one label per panel is adequate.This is incorrect. If a printed or embossed or watermark label was used, the printing, embossing, or watermark would be required every three feet. If a permanent label is used, one label per panel is adequate.
34. Framed Products The label shall be on the side or bottom facing the exterior
36. Impact Resistant Coverings Product Approval Holder Sample
37. Impact Resistant Coverings Association or Distributors Sample